{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1024-1AG60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1024-1AG60","canonicalUrl":"https://aoctrl.com/siemens/3RT1024-1AG60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1024-1AG60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS S0 power contactor, 3RT1024-1AG60, 7.5 kW at 690 V, 12.5 A AC-4, screw-type terminals, 45 mm wide, DIN-rail mount.","salesMarkdown":"The Siemens 3RT1024-1AG60 is a SIRIUS S0-frame power contactor rated to switch motor loads up to 7.5 kW at 690 V (AC-3) and 7.5 kW at 500 V, with an AC-4 rated operational current of 12.5 A at 400 V — that's the reversing/plugging duty cycle, so it handles the inrush of a motor stopping under load without welding contacts. Snap it onto a 35 mm DIN rail per EN 50022 or screw-mount — the S0 frame footprint is 45 mm wide, 85 mm tall, 91 mm deep, leaving room for a 6 mm side clearance when ganged side-by-side. ## Coordination and wiring — what the fuse callouts mean Main circuit screw terminals accept 2x (0.5–1.5 mm²), 2x (0.75–2.5 mm²), or up to 2x 4 mm² solid; for stranded, 2x (1–2.5 mm²), 2x (2.5–6 mm²), or max 2x 10 mm² — AWG equivalents 2x (16–12), 2x (14–10), or 1x 8. ## Environmental range Rated for 50/60 Hz supply with a voltage tolerance of 0.8–1.1 x rated at 50 Hz and 0.85–1.1 x rated at 60 Hz.","metaTitle":"Siemens 3RT1024-1AG60 SIRIUS S0 Power Contactor, 7.5 kW at 6","metaDescription":"Siemens 3RT1024-1AG60 SIRIUS S0 power contactor, 7.5 kW at 690 V, 12.5 A AC-4, screw terminals, 45 mm wide, current production. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"91 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"85 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP00","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S0","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"100 V","at 500 V rated value":"7.5 kW","at 60 Hz rated value":"100 ... 110 V","at 690 V rated value":"7.5 kW","Instantaneous Contact":"0","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (1 ... 2,5 mm²), 2x (2,5 ... 6 mm²), max. 2x 10 mm²","at AC-2 at 400 V rated value":"5.5 kW","at AC-4 at 400 V rated value":"12.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 25 A","at AWG conductors for main contacts":"2x (16 ... 12), 2x (14 ... 10), 1x 8","With Type Of Coordination 1 Required":"fuse gL/gG: 63 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"40 A","Apparent holding power of magnet coil at AC":"7.5 V·A","Apparent pick-up power of magnet coil at AC":"69 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.76","Inductive power factor with the holding power of the coil":"0.28","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=345939&mlfb=3RT1024-1AG60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1024-1AG60/alternatives.json"},"ai":{"faq":[{"question":"What is 3RT1024-1AG60's depth on this component line?","answer":"The depth is 91 mm, with a width of 45 mm and height of 85 mm — S0 frame size."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1024-1AG60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1024-1AG60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}