{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1024-1AP60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1024-1AP60","canonicalUrl":"https://aoctrl.com/siemens/3RT1024-1AP60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1024-1AP60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT1024-1AP60 power contactor, S0 frame, 45 mm width, screw terminals, 7.5 kW at 400 V AC-3, 12.5 A AC-4.","salesMarkdown":"It delivers 7.5 kW at 400 V in AC-3 duty and carries an AC-4 rating of 12.5 A at the same voltage, covering reversing and inching applications where contact wear is the limiting factor. The AC-3 motor rating of 7.5 kW at 400 V and 690 V means this contactor handles a standard 10 HP induction motor on a 400 V line, or the same power on a 690 V delta-connected motor — the voltage class doesn't change the kW, which is unusual and tells you the contactor is sized for the current, not the voltage, in AC-3. Auxiliary contact ratings span from 10 A at 24 V up to 0.3 A at 220 V, covering PLC-level signal switching on the same device. Side-by-side mounting is permitted — the 6 mm spacing to adjacent devices on the side is the minimum for heat dissipation, not an electrical clearance requirement. The main circuit terminals accept 2x (0.5…1.5 mm²), 2x (0.75…2.5 mm²), and up to 2x 10 mm² solid or stranded, with AWG equivalents from 16 to 8. That covers most panel wiring from control-circuit 1.5 mm² up to motor-circuit 10 mm² in one terminal clamp. Front face is IP20; the terminal area is IP00 — standard for a panel-mounted contactor where the enclosure provides the overall IP rating.","metaTitle":"Siemens 3RT1024-1AP60 SIRIUS Power Contactor, S0 Frame, 7.5","metaDescription":"Siemens 3RT1024-1AP60 SIRIUS power contactor, S0 frame size, 7.5 kW at 400 V AC-3. Screw terminals, 45 mm wide, snap-on DIN rail. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"91 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"85 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.8 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP00","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S0","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"220 V","at 500 V rated value":"7.5 kW","at 60 Hz rated value":"240 V","at 690 V rated value":"7.5 kW","Instantaneous Contact":"0","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (1 ... 2,5 mm²), 2x (2,5 ... 6 mm²), max. 2x 10 mm²","at AC-2 at 400 V rated value":"5.5 kW","at AC-4 at 400 V rated value":"12.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 25 A","at AWG conductors for main contacts":"2x (16 ... 12), 2x (14 ... 10), 1x 8","With Type Of Coordination 1 Required":"fuse gL/gG: 63 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"40 A","Apparent holding power of magnet coil at AC":"7.5 V·A","Apparent pick-up power of magnet coil at AC":"69 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.76","Inductive power factor with the holding power of the coil":"0.28","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$69.30","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=286124&mlfb=3RT1024-1AP60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1024-1AP60/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional alternative to 3RT1024-1AP60?","answer":"The 3RT1017-1AP01 is a smaller-frame SIRIUS contactor (S00) with lower motor ratings. It will not drop into the same panel footprint without rewiring the busbar and DIN rail position — the S0 frame of the 3RT1024 is 45 mm wide versus the S00's 22.5 mm. The 3RT1034-1AN60 is a larger S0 variant with higher current capacity. The 3RT1024 sits in the middle of the S0 power band."},{"question":"What is the depth of 3RT1024-1AP60?","answer":"The overall depth is 91 mm, measured from the mounting surface to the furthest projecting point of the contactor body."},{"question":"What wire sizes does the main circuit accept?","answer":"The screw terminals accept 2x (0.5…1.5 mm²), 2x (0.75…2.5 mm²), and up to 2x (0.75…4 mm²) solid, or 2x (1…2.5 mm²) and 2x (2.5…6 mm²) stranded, with a maximum of 2x 10 mm². AWG equivalents are 2x (16…12), 2x (14…10), and 1x 8."},{"question":"What compliance documentation is available for this part?","answer":"The product is a standard Siemens SIRIUS catalog item and carries the usual CE marking for the European low-voltage directive. Specific RoHS, REACH, and UL documentation is available through the standard Siemens documentation portal tied to the order code."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1024-1AP60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1024-1AP60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}