{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1024-3AN20-1AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1024-3AN20-1AA0","canonicalUrl":"https://aoctrl.com/siemens/3RT1024-3AN20-1AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1024-3AN20-1AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS S0 power contactor, 3RT1024-3AN20-1AA0, screw terminals, 7.5 kW at 690 V AC-3, 45 mm width, active production.","salesMarkdown":"The Siemens SIRIUS 3RT1024-3AN20-1AA0 is a size S0 power contactor rated for motor switching up to 7.5 kW at 690 V AC-3 (or 7.5 kW at 500 V). In AC-2 duty at 400 V it handles 5.5 kW, and in AC-4 (reversing/inching) it carries 12.5 A at 400 V. Front protection is IP20; the terminal area is IP00 — keep live parts behind a panel door or cover. The integrated auxiliary contact (1 NO + 0 NC) is rated 10 A at 24 V, 6 A at 230 V, and 3 A at 400 V — sufficient for signaling to a PLC or pilot lamp. At 220 V DC the rating drops to 0.3 A; verify DC load break capability for your specific inductive load.","metaTitle":"Siemens 3RT1024-3AN20-1AA0 SIRIUS Power Contactor, S0, 7.5 k","metaDescription":"Siemens SIRIUS 3RT1024-3AN20-1AA0 power contactor, size S0, rated 7.5 kW at 690 V AC-3. Screw terminals, 45 mm width, active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"91 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"85 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP00","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S0","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"220 V","at 500 V rated value":"7.5 kW","at 60 Hz rated value":"220 V","at 690 V rated value":"7.5 kW","Instantaneous Contact":"0","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (1 ... 2,5 mm²), 2x (2,5 ... 6 mm²), max. 2x 10 mm²","at AC-2 at 400 V rated value":"5.5 kW","at AC-4 at 400 V rated value":"12.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 25 A","at AWG conductors for main contacts":"2x (16 ... 12), 2x (14 ... 10), 1x 8","With Type Of Coordination 1 Required":"fuse gL/gG: 63 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (24 ... 14)","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"spring-loaded terminals","at ambient temperature 40 °C rated value":"40 A","Apparent holding power of magnet coil at AC":"8.4 V·A","Apparent pick-up power of magnet coil at AC":"64 V·A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.72","Inductive power factor with the holding power of the coil":"0.24","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=212748&mlfb=3RT1024-3AN20-1AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1024-3AN20-1AA0/alternatives.json"},"ai":{"faq":[{"question":"Will 3RT1024-3AN20-1AA0 drop into a panel specified around 3RT1023-1AL20 without rewiring?","answer":"Both are S0 size on 35 mm DIN rail, so the mechanical footprint is the same. However, the 3RT1024-3AN20-1AA0 has a different auxiliary contact arrangement (1 NO, 0 NC) and higher main current rating — verify that the existing wiring and fuse coordination (Type 2 requires 25 A gL/gG) match the new contactor's ratings before swapping."},{"question":"Where can I buy 3RT1024-3AN20-1AA0?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit a request for quote to confirm current availability and pricing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1024-3AN20-1AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1024-3AN20-1AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}