{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1025-1AC24-0AA1-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1025-1AC24-0AA1-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RT1025-1AC24-0AA1-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1025-1AC24-0AA1-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, S0 size, 24 VAC 50/60 Hz coil, screw-type terminals, IP20 front, snap-on 35 mm DIN rail.","salesMarkdown":"The 24 VAC coil (50/60 Hz) pulls in reliably across the full rated control voltage range — 0.8 to 1.1 x Us at 50 Hz, 0.85 to 1.1 x Us at 60 Hz — so a saggy control transformer on a long run still holds it closed. The 45 mm width and 85 mm height keep it within the S0 footprint; depth is 140 mm, so check gland-plate clearance if the panel is shallow. Front face carries IP20 protection — safe for finger-probe access inside a locked cabinet. The terminal area itself is IP00, meaning the screw terminals are exposed when the cover is off; standard practice is to keep the panel door interlocked or use a finger-safe shroud if live work is possible. The 3RT1025-1AC24-0AA1-ZW97 uses a 24 VAC coil. If your panel runs on 24 VDC control, the closest peer in the same S0 frame is the 3RT1023-1AL20 (24 VDC coil). The mechanical footprint and terminal layout are identical — swap the coil voltage, not the wiring. The DC coil version draws a continuous hold current; the AC coil uses a laminated magnet and may hum if the voltage dips below the dropout threshold.","metaTitle":"Siemens 3RT1025-1AC24-0AA1-ZW97 SIRIUS Power Contactor, 24 V","metaDescription":"Siemens SIRIUS 3RT1025-1AC24-0AA1-ZW97 power contactor, S0 size, 24 VAC 50/60 Hz coil, screw terminals, IP20 front. Rated for pollution degree 3. In current production. Sourced to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"140 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"85 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP00","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S0","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"24 V","at 500 V rated value":"10 kW","at 60 Hz rated value":"24 V","at 690 V rated value":"11 kW","Instantaneous Contact":"2","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (1 ... 2,5 mm²), 2x (2,5 ... 6 mm²), max. 2x 10 mm²","at AC-2 at 400 V rated value":"7.5 kW","at AC-4 at 400 V rated value":"15.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 25 A","at AWG conductors for main contacts":"2x (16 ... 12), 2x (14 ... 10), 1x 8","With Type Of Coordination 1 Required":"fuse gL/gG: 63 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"40 A","Apparent holding power of magnet coil at AC":"8.4 V·A","Apparent pick-up power of magnet coil at AC":"64 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.72","Inductive power factor with the holding power of the coil":"0.24","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=169507&mlfb=3RT1025-1AC24-0AA1-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1025-1AC24-0AA1-ZW97/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RT1025-1AC24-0AA1-ZW97?","answer":"Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels."},{"question":"Will 3RT1025-1AC24-0AA1-ZW97 drop into a panel specified around 3RT1023-1AL20 without rewiring?","answer":"Yes, the S0 frame size and screw-terminal layout are identical. The only difference is the coil voltage — 24 VAC versus 24 VDC. No rewiring is needed for the power circuit, but the control circuit must supply AC rather than DC."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1025-1AC24-0AA1-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1025-1AC24-0AA1-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}