{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1025-1AV60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1025-1AV60","canonicalUrl":"https://aoctrl.com/siemens/3RT1025-1AV60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1025-1AV60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S0, 3-pole, screw terminals, 45 mm width, 11 kW at 690 V AC-3, IP20 front.","salesMarkdown":"## SIRIUS S0 power contactor — panel fit and ratings Rated for motor switching at 11 kW on a 690 V three-phase supply under AC-3 duty, and 7.5 kW at 400 V AC-2. For resistive loads (AC-1), the maximum operating current is 10 A. DC switching capability is given per voltage: 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V. ## Coordination and wiring Main circuit terminals are screw-type, accepting solid conductors up to 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), and a maximum of 2x (0.75 to 4 mm²). For stranded wire, the range is 2x (1 to 2.5 mm²), 2x (2.5 to 6 mm²), and max 2x 10 mm². AWG equivalents: 2x (16 to 12), 2x (14 to 10), and 1x 8. Strip length and torque specs should follow the standard SIRIUS S0 terminal data. Type 2 coordination requires 25 A.","metaTitle":"Siemens 3RT1025-1AV60 SIRIUS Power Contactor, S0, 3-Pole, 11","metaDescription":"Siemens 3RT1025-1AV60 SIRIUS power contactor, size S0, 3 NO main contacts, screw terminals, 45 mm wide, IP20 front, rated 11 kW at 690 V AC-3. Current production. Order to RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"91 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"85 mm","Maximum":"2 000 m","at 60 Hz":"0.8 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP00","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S0","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 500 V rated value":"10 kW","at 60 Hz rated value":"480 V","at 690 V rated value":"11 kW","Instantaneous Contact":"0","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (1 ... 2,5 mm²), 2x (2,5 ... 6 mm²), max. 2x 10 mm²","at AC-2 at 400 V rated value":"7.5 kW","at AC-4 at 400 V rated value":"15.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 25 A","at AWG conductors for main contacts":"2x (16 ... 12), 2x (14 ... 10), 1x 8","With Type Of Coordination 1 Required":"fuse gL/gG: 63 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"40 A","Apparent holding power of magnet coil at AC":"7.5 V·A","Apparent pick-up power of magnet coil at AC":"69 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.76","Inductive power factor with the holding power of the coil":"0.28","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=15744&mlfb=3RT1025-1AV60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1025-1AV60/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RT1025-1AV60 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What are the key ratings for 3RT1025-1AV60?","answer":"Rated 11 kW at 690 V AC-3, 7.5 kW at 400 V AC-2, 15.5 A at 400 V AC-4. DC ratings include 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, and 0.3 A at 220 V. Mechanical life is 10 million cycles."},{"question":"Will 3RT1025-1AV60 drop into a panel specified around 3RT1023-1AL20 without rewiring?","answer":"Both are SIRIUS S0 frame contactors with the same 45 mm width and DIN rail mounting, so the mechanical fit and footprint match. However, verify that the coil voltage and terminal wiring ratings on the 3RT1023-1AL20 match your panel design — the 3RT1025-1AV60 uses screw terminals and has different power ratings."},{"question":"What is the depth of 3RT1025-1AV60?","answer":"The depth is 91 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1025-1AV60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1025-1AV60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}