{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1026-1AL24-3MA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1026-1AL24-3MA0","canonicalUrl":"https://aoctrl.com/siemens/3RT1026-1AL24-3MA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1026-1AL24-3MA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT1026-1AL24-3MA0 power contactor, size S0, 11 kW at 500 V AC-3, 15.5 A AC-4, screw terminals, DIN rail mount.","salesMarkdown":"The S0 footprint is 45 mm wide by 85 mm tall by 140 mm deep — a common size that fits alongside other SIRIUS components on the same rail. ## Wiring and terminal details Main current circuit uses screw-type terminals accepting 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or up to 2x 4 mm² solid — or AWG equivalents 2x (16 to 12), 2x (14 to 10), or 1x 8. For type 1 coordination (welding allowed), use gL/gG 100 A.","metaTitle":"Siemens 3RT1026-1AL24-3MA0 SIRIUS Power Contactor, 11 kW at","metaDescription":"Siemens SIRIUS 3RT1026-1AL24-3MA0 power contactor, size S0, 11 kW at 500 V AC-3, 15.5 A AC-4. Current production. Screw terminals, DIN rail mount. Source to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"140 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"85 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP00","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S0","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"230 V","at 500 V rated value":"11 kW","at 60 Hz rated value":"230 V","at 690 V rated value":"11 kW","Instantaneous Contact":"2","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (1 ... 2,5 mm²), 2x (2,5 ... 6 mm²), max. 2x 10 mm²","at AC-2 at 400 V rated value":"11 kW","at AC-4 at 400 V rated value":"15.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 35 A","at AWG conductors for main contacts":"2x (16 ... 12), 2x (14 ... 10), 1x 8","With Type Of Coordination 1 Required":"fuse gL/gG: 100 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"40 A","Apparent holding power of magnet coil at AC":"8.4 V·A","Apparent pick-up power of magnet coil at AC":"64 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.72","Inductive power factor with the holding power of the coil":"0.24","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=470765&mlfb=3RT1026-1AL24-3MA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1026-1AL24-3MA0/alternatives.json"},"ai":{"faq":[{"question":"What are the key motor ratings for this contactor?","answer":"It is rated 11 kW at 500 V AC-3 for standard motor starting, 11 kW at 400 V AC-2 for slip-ring motors, and 15.5 A at 400 V AC-4 for high-inrush reversing duty."},{"question":"What fuse coordination does this contactor require?","answer":"For type 2 coordination (no weld), use a gL/gG 35 A fuse upstream. For type 1 coordination, a gL/gG 100 A fuse is permitted."},{"question":"Can this contactor be mounted side-by-side with others?","answer":"Yes, side-by-side mounting is allowed without derating up to 60 °C ambient, which simplifies panel layout."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1026-1AL24-3MA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1026-1AL24-3MA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}