{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1034-1AB00","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1034-1AB00","canonicalUrl":"https://aoctrl.com/siemens/3RT1034-1AB00","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1034-1AB00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, Size S2, 3RT1034-1AB00, 55 mm width, screw-type terminals, AC-3 18.5 kW at 500 V, AC-2 15 kW at 400 V, 24 V 50 Hz coil.","salesMarkdown":"It carries an AC-3 motor rating of 18.5 kW at 500 V and 15 kW at 400 V under AC-2 duty, which covers standard squirrel-cage motors and slip-ring motors respectively. The coil is rated for 24 V at 50 Hz, drawing 10 A at 24 V and 6 A at 230 V, with an operating range of 0.8 to 1.1 times the rated voltage at 50 Hz. These timing figures matter for coordination with upstream short-circuit protection devices — the contactor clears the arc within the let-through energy window of a typical gG fuse or motor circuit breaker. Main circuit terminals are screw-type, accepting solid conductors from 2x 0.5 mm² up to 2x 4 mm², and stranded conductors from 2x 0.75 mm² up to 2x 25 mm². The minimum permissible cross-section at 40 °C is 16 mm² for the main circuit. ## Mechanical Endurance and Switching Rates Maximum switching rates vary by duty: 1,200 cycles per hour at AC-1 (resistive), 1,000 at AC-3 (motor running), 750 at AC-2 (slip-ring motor starting), and 250 at AC-4 (plugging/inching). For a conveyor line running at 30 starts per hour, the AC-3 rate gives decades of service life; for a reversing application at 100 cycles per hour, the AC-4 rate still leaves headroom.","metaTitle":"Siemens 3RT1034-1AB00 SIRIUS Power Contactor, Size S2, 55 mm","metaDescription":"Siemens SIRIUS 3RT1034-1AB00 power contactor, Size S2, 55 mm wide. AC-3 motor rating 18.5 kW at 500 V. Active production. DIN rail mount. RFQ for pricing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"115 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"55 mm","at AC":"7 ... 20 ms","Height":"112 mm","Stranded":"2x (0.75 ... 25 mm²)","at 50 Hz":"0.8 ... 1.1","Arcing Time":"10 ... 15 ms","On The Front":"IP20","1 Rated Value":"50 Hz","During Storage":"-55 ... +80 °C","Of The Terminal":"IP00","at AC-1 maximum":"1 200 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.75 ... 16 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"24 V","at 500 V rated value":"18.5 kW","at 690 V rated value":"10 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"15 kW","at AC-4 at 400 V rated value":"29 A","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"16 mm²","at 60 °C minimum permissible":"10 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"18 kW","at 690 V at 60 °C rated value":"54 kW","at AWG cables for main contacts":"2x (18 ... 2)","For Auxiliary And Control Circuit":"screw-type terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 63 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"fuse gL/gG: 125 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Thermal Short-Time Current Limited To 10 S":"320 A","Finely Stranded Without Core End Processing":"2x (0.75 ... 16 mm²)","apparent holding power of magnet coil at AC":"9.7 VA","apparent pick-up power of magnet coil at AC":"104 VA","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.78","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.42","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"0","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=17262&mlfb=3RT1034-1AB00","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1034-1AB00/alternatives.json"},"ai":{"faq":[{"question":"What are the key motor ratings for this contactor?","answer":"AC-3 motor rating is 18.5 kW at 500 V and 10 kW at 690 V. AC-2 rating is 15 kW at 400 V. AC-4 rating at 400 V is 29 A. The coil is 24 V at 50 Hz."},{"question":"What conductor sizes does the screw terminal accept?","answer":"Solid conductors: 2x 0.5 to 1.5 mm², 2x 0.75 to 2.5 mm², max 2x 0.75 to 4 mm². Stranded: 2x 0.75 to 25 mm². Solid or stranded: 2x 0.75 to 16 mm². Minimum at 40 °C is 16 mm² for the main circuit."},{"question":"What are the physical dimensions?","answer":"Width 55 mm, height 112 mm, depth 115 mm. It mounts on 35 mm DIN rail per DIN EN 50022, with side-by-side mounting permitted."},{"question":"What compliance documentation is available?","answer":"RoHS compliance is confirmed with a substance prohibition date of 05/01/2012. The contactor carries pollution degree 3 rating for industrial environments. IP20 front protection, IP00 at terminals."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1034-1AB00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1034-1AB00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}