{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1034-1AL00-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1034-1AL00-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RT1034-1AL00-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1034-1AL00-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT1034-1AL00-ZX95 power contactor, Size S2, screw-type terminals, snap-on DIN rail mount, 15 kW at AC-2 400 V.","salesMarkdown":"## Motor Switching Ratings — What the Duty Classes Mean Rated 15 kW at AC-2 duty at 400 V, this contactor handles slip-ring motor starting where the load current stays below make/break stress. For AC-4 duty (plugging, inching, reversing) at 400 V, it carries 29 A — the more severe switching class that governs contact life under frequent reversals. The AC-3 maximum operating rate of 1,000 cycles per hour suits conveyor and pump cycling, while AC-4 maxes at 250 cycles per hour due to the heavier arc stress. Substance prohibitance dated 05/01/2012 aligns with RoHS and REACH compliance timelines. The SIRIUS series carries IEC and UL certifications for global panel acceptance, though specific agency marks are not listed in this record.","metaTitle":"Siemens 3RT1034-1AL00-ZX95 SIRIUS Power Contactor, Size S2,","metaDescription":"Siemens SIRIUS 3RT1034-1AL00-ZX95 power contactor, Size S2, rated 15 kW at AC-2 400 V, 29 A at AC-4 400 V. Screw terminals, snap-on DIN rail. Current lifecycle stage. Sourced to or","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"115 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"55 mm","at AC":"7 ... 20 ms","Height":"112 mm","Stranded":"2x (0.75 ... 25 mm²)","at 50 Hz":"0.8 ... 1.1","Arcing Time":"10 ... 15 ms","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","During Storage":"-55 ... +80 °C","Of The Terminal":"IP00","at AC-1 maximum":"1 200 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.75 ... 16 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"125 V","at 500 V rated value":"18.5 kW","at 690 V rated value":"10 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"15 kW","at AC-4 at 400 V rated value":"29 A","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"16 mm²","at 60 °C minimum permissible":"10 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"18 kW","at 690 V at 60 °C rated value":"54 kW","at AWG cables for main contacts":"2x (18 ... 2)","For Auxiliary And Control Circuit":"screw-type terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 63 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"fuse gL/gG: 125 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Thermal Short-Time Current Limited To 10 S":"320 A","Finely Stranded Without Core End Processing":"2x (0.75 ... 16 mm²)","apparent holding power of magnet coil at AC":"9.7 VA","apparent pick-up power of magnet coil at AC":"104 VA","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.78","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.42","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"0","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=510709&mlfb=3RT1034-1AL00-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1034-1AL00-ZX95/alternatives.json"},"ai":{"faq":[{"question":"What are the key motor ratings for this contactor?","answer":"It is rated 15 kW at AC-2 duty at 400 V for slip-ring motor starting, and 29 A at AC-4 duty at 400 V for severe switching applications like plugging and reversing."},{"question":"What is the mounting method and footprint?","answer":"It mounts via screw and snap-on onto 35 mm standard DIN rail per DIN EN 50022. The width is 55 mm, depth 115 mm, and height 112 mm, allowing tight side-by-side mounting without derating."},{"question":"What conductor sizes does the screw terminal accept?","answer":"Solid conductors: 2x (0.5...1.5 mm²), 2x (0.75...2.5 mm²), max 2x (0.75...4 mm²). Stranded: 2x (0.75...25 mm²)."},{"question":"How does this compare to the 3RT1036-1AB00?","answer":"The 3RT1036-1AB00 is a larger frame (Size S3) with higher current ratings. The 3RT1034-1AL00-ZX95 (Size S2) is a smaller, lower-rated contactor. They share the same SIRIUS platform and DIN rail mounting, but the 3RT1036 will not drop into a panel wired for the S2 footprint without rewiring the main power lugs and checking panel fill factor."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1034-1AL00-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1034-1AL00-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}