{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1034-1AL20-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1034-1AL20-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RT1034-1AL20-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1034-1AL20-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, 3RT1034-1AL20-ZX95, size S2, screw-type terminals, 15 kW at AC-2 400 V, 55 mm wide, for 35 mm DIN rail.","salesMarkdown":"The 55 mm width and 112 mm height keep it compact for dense panel layouts. Rated for AC-2 duty at 15 kW on a 400 V 50/60 Hz supply, this contactor handles wound-rotor motors or other loads where the inrush is moderate but the switching frequency is regular. ## Terminal wiring and auxiliary contact capacity Main circuit terminals accept solid conductors from 2x 0.5 mm² up to max 2x 4 mm², and stranded up to 2x 25 mm². The screw-type terminals are rated IP00 at the connection point, while the front face carries IP20 for basic finger-safe touch protection inside the enclosure. The built-in auxiliary contacts are rated for 10 A at 24 V, 6 A at 230 V, and 3 A at 400 V — enough to drive a PLC input or a small relay directly, but verify the load type against the AC/DC curve if switching an inductive load like a contactor coil. ## Environmental limits and switching endurance Switching frequency limits: 1200 cycles/hour at AC-1 (resistive), 1000 at AC-3 (squirrel-cage motor), 750 at AC-2, and 250 at AC-4 (plugging/inching). For a takt-time line running 10-second cycles, AC-3 stays well under the 1000/h ceiling — holds takt time without margin concerns.","metaTitle":"Siemens SIRIUS 3RT1034-1AL20-ZX95 Power Contactor, Size S2,","metaDescription":"Siemens SIRIUS 3RT1034-1AL20-ZX95 power contactor, size S2. Rated 15 kW at AC-2 400 V. Screw terminals, 55 mm wide. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"115 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"55 mm","at AC":"7 ... 20 ms","Height":"112 mm","Stranded":"2x (0.75 ... 25 mm²)","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","Arcing Time":"10 ... 15 ms","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","During Storage":"-55 ... +80 °C","Of The Terminal":"IP00","at AC-1 maximum":"1 200 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.75 ... 16 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"230 V","at 500 V rated value":"18.5 kW","at 60 Hz rated value":"230 V","at 690 V rated value":"10 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"15 kW","at AC-4 at 400 V rated value":"29 A","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"16 mm²","at 60 °C minimum permissible":"10 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"18 kW","at 690 V at 60 °C rated value":"54 kW","at AWG cables for main contacts":"2x (18 ... 2)","For Auxiliary And Control Circuit":"screw-type terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 63 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"fuse gL/gG: 125 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Thermal Short-Time Current Limited To 10 S":"320 A","Finely Stranded Without Core End Processing":"2x (0.75 ... 16 mm²)","apparent holding power of magnet coil at AC":"11.3 VA","apparent pick-up power of magnet coil at AC":"127 VA","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.73","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.41","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"0","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=454003&mlfb=3RT1034-1AL20-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1034-1AL20-ZX95/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"The headline rating is 15 kW at AC-2 duty on 400 V 50/60 Hz. It also carries an AC-3 rating for squirrel-cage motors, though the exact kW figure is not listed here. Auxiliary contacts are rated at 10 A at 24 V, 6 A at 230 V, and 3 A at 400 V."},{"question":"What wire sizes does the 3RT1034-1AL20-ZX95 accept?","answer":"Solid: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), max 2x (0.75 to 4 mm²). Stranded: 2x (0.75 to 25 mm²). Main circuit terminals are screw-type."},{"question":"What is the mounting and dimension footprint?","answer":"Width 55 mm, height 112 mm, depth 115 mm. Mounts on 35 mm DIN rail per DIN EN 50022 via screw or snap-on. Side-by-side mounting is allowed."},{"question":"Does the 3RT1034-1AL20-ZX95 drop into a panel specified for the 3RT1034-1AN60-1AA0?","answer":"Both are size S2 SIRIUS contactors with the same 55 mm width and DIN-rail mounting, so the mechanical footprint is identical. However, the -1AN60-1AA0 variant uses a different coil voltage (not listed here), so verify coil compatibility before assuming a drop-in swap. The main terminal wiring and auxiliary contact ratings may also differ — check the specific datasheet for the alternate code."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1034-1AL20-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1034-1AL20-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}