{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1034-3AV60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1034-3AV60","canonicalUrl":"https://aoctrl.com/siemens/3RT1034-3AV60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1034-3AV60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, 3RT1034-3AV60, size S2, screw-type terminals, 29 A AC-4 at 400 V, 18.5 kW at 500 V, 55 mm width, DIN rail mount.","salesMarkdown":"At AC-4 duty (plugging, inching, reversing) the contactor is rated 29 A at 400 V. That is the heavy switching category for frequent motor reversals or jogging — the 250 cycles-per-hour maximum at AC-4 tells you this part is built for that abuse, not just continuous running. For motor starting (AC-3), the contactor handles 18.5 kW at 500 V. That is the standard rating for squirrel-cage motors during start and run, and the 1,000 cycles-per-hour AC-3 rating means it handles frequent starts on a conveyor or pump line. The auxiliary contacts are rated 10 A at 24 V, 6 A at 230 V, and 0.3 A at 220 V DC. For a 24 VDC PLC interlock circuit, the 10 A rating gives plenty of headroom. The solid wire range is 2x (0.25 to 2.5 mm²) for control wiring, and stranded accepts 2x (0.75 to 25 mm²) for the power loop. At 40 °C, the minimum permissible cross-section is 16 mm² for full rated current — that is a #6 AWG equivalent, so plan your lugging accordingly. The front face carries IP20, meaning finger-safe when installed in an enclosure.","metaTitle":"Siemens 3RT1034-3AV60 SIRIUS Power Contactor, S2, 29A AC-4","metaDescription":"Siemens SIRIUS power contactor 3RT1034-3AV60, size S2, 29A AC-4 at 400V, 18.5kW at 500V. Screw terminals, DIN rail mount. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"115 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"55 mm","at AC":"7 ... 20 ms","Height":"112 mm","Stranded":"2x (0.75 ... 25 mm²)","at 60 Hz":"0.8 ... 1.1","Arcing Time":"10 ... 15 ms","On The Front":"IP20","1 Rated Value":"60 Hz","During Storage":"-55 ... +80 °C","Of The Terminal":"IP00","at AC-1 maximum":"1 200 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.75 ... 16 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 500 V rated value":"18.5 kW","at 60 Hz rated value":"480 V","at 690 V rated value":"10 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"15 kW","at AC-4 at 400 V rated value":"29 A","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"16 mm²","at 60 °C minimum permissible":"10 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"18 kW","at 690 V at 60 °C rated value":"54 kW","at AWG cables for main contacts":"2x (18 ... 2)","For Auxiliary And Control Circuit":"spring-loaded terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 63 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"fuse gL/gG: 125 A","at AWG cables for auxiliary contacts":"2x (24 ... 14)","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Thermal Short-Time Current Limited To 10 S":"320 A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","apparent holding power of magnet coil at AC":"10.1 VA","apparent pick-up power of magnet coil at AC":"120 VA","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.7","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.42","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"0","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=517517&mlfb=3RT1034-3AV60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1034-3AV60/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional alternative to 3RT1034-3AV60?","answer":"The peer 3RT1036-1AB00 is a size S2 contactor but with different coil voltage and terminal configuration. The 3RT1034-3AV60 uses screw terminals and a specific coil; verify the coil rating before substituting. The 3RT1017-1AP01 and 3RT1015-1BB42 are smaller frame sizes (S0) and will not carry the same AC-4 current — they are not drop-in replacements without rewiring and derating."},{"question":"What is the depth of this contactor?","answer":"The depth is 115 mm. That is the dimension from the DIN rail mounting surface to the front of the arc chamber — account for this when sizing the enclosure depth and clearance for wiring ducts."},{"question":"What solid wire range does the control terminal accept?","answer":"The solid wire range for the control terminals is 2x (0.25 to 2.5 mm²). For the main power circuit, stranded wire up to 2x (0.75 to 25 mm²) is accepted."},{"question":"Will 3RT1034-3AV60 drop into a panel specified for 3RT1036-1AB00?","answer":"Both are size S2 contactors with the same 55 mm width and DIN rail mounting, so the physical footprint and rail position match. However, the coil voltage and auxiliary contact configuration may differ — check the coil rating on the nameplate before assuming a direct swap."},{"question":"What compliance documentation is available for this contactor?","answer":"The substance prohibitance date of 05/01/2012 confirms RoHS compliance for that cutoff. The SIRIUS series typically carries UL, CSA, and CE approvals, though the specific listing for this order code should be verified from the nameplate or Siemens declaration."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1034-3AV60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1034-3AV60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}