{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1034-3EG28-0MA3","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1034-3EG28-0MA3","canonicalUrl":"https://aoctrl.com/siemens/3RT1034-3EG28-0MA3","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1034-3EG28-0MA3","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S2, order code 3RT1034-3EG28-0MA3, 18.5 kW at 500 V, screw-type terminals, IP20 front, DIN-rail mount.","salesMarkdown":"The Siemens 3RT1034-3EG28-0MA3 is a SIRIUS power contactor in size S2, rated for switching motor loads up to 18.5 kW at 500 V and 10 kW at 690 V. The 18.5 kW rating at 500 V tells you this contactor handles a 25–30 A motor load on a 500 V three-phase line — common for medium-horsepower pumps or conveyors. The 10 kW at 690 V covers higher-voltage industrial networks. The auxiliary contact ratings (10 A at 24 V, 6 A at 230 V, 3 A at 400 V) define the control-circuit capacity: at 24 VDC it switches 10 A, enough for a PLC output driving multiple relays; at 230 VAC it drops to 6 A, still fine for a pilot lamp or small solenoid. The 55 mm width and 129 mm height fit a standard 8-module DIN-rail slot. The IP20 front enclosure protects against finger contact; the terminal area is IP00, meaning bare conductors are exposed — standard for panel-mount contactors, but keep the gland plate clear of live parts.","metaTitle":"Siemens 3RT1034-3EG28-0MA3 SIRIUS Power Contactor, 18.5 kW /","metaDescription":"Siemens 3RT1034-3EG28-0MA3 SIRIUS power contactor, size S2, 18.5 kW at 500 V, screw terminals, IP20 front, DIN-rail mount. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"164 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"55 mm","at AC":"15g / 5 ms, 8g / 10 ms","at DC":"20 ... 30 ms","Height":"129 mm","Stranded":"2x (0.75 ... 25 mm²)","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","Arcing Time":"10 ... 15 ms","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","During Storage":"-55 ... +80 °C","Of The Terminal":"IP00","at AC-1 maximum":"1 200 1/h","at AC-2 maximum":"750 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.75 ... 16 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"110 V","at 500 V rated value":"18.5 kW","at 60 Hz rated value":"110 V","at 690 V rated value":"10 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"15 kW","at AC-4 at 400 V rated value":"29 A","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"16 mm²","at 60 °C minimum permissible":"10 mm²","Design Of The Surge Suppressor":"with RC elements","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"18 kW","at 690 V at 60 °C rated value":"54 kW","at AWG cables for main contacts":"2x (18 ... 2)","For Auxiliary And Control Circuit":"spring-loaded terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 63 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"fuse gL/gG: 125 A","at AWG cables for auxiliary contacts":"2x (24 ... 14)","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Thermal Short-Time Current Limited To 10 S":"320 A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","apparent holding power of magnet coil at AC":"11.3 VA","apparent pick-up power of magnet coil at AC":"127 VA","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.73","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.41","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=510635&mlfb=3RT1034-3EG28-0MA3","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1034-3EG28-0MA3/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of 3RT1034-3EG28-0MA3?","answer":"The depth is 164 mm, which is standard for the S2 contactor frame."},{"question":"What wire sizes does the solid terminal accept?","answer":"The solid terminal accepts 2x (0.25 to 2.5 mm²) for the auxiliary circuit; the main circuit accepts stranded 2x (0.75 to 25 mm²)."},{"question":"Will 3RT1034-3EG28-0MA3 drop into a panel specified for 3RT1044-1FB46?","answer":"No — 3RT1044-1FB46 is a larger frame (size S3 or S6) with different dimensions and terminal spacing. The S2 frame of this part is narrower and shorter, so a panel cutout or DIN-rail layout designed for the larger contactor would need rework."},{"question":"Where can I buy 3RT1034-3EG28-0MA3?","answer":"This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1034-3EG28-0MA3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1034-3EG28-0MA3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}