{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1035-1AN60-1AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1035-1AN60-1AA0","canonicalUrl":"https://aoctrl.com/siemens/3RT1035-1AN60-1AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1035-1AN60-1AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S2, 3RT1035-1AN60-1AA0, 22 kW at 500 V AC-3, 55 mm wide, screw-type terminals, snap-on DIN rail mount.","salesMarkdown":"The Siemens SIRIUS 3RT1035-1AN60-1AA0 is a size S2 power contactor rated for motor switching up to 22 kW at 500 V in AC-3 duty, and 11.4 kW at 690 V. It also carries an AC-2 rating of 18.5 kW at 400 V, covering wound-rotor motor or slip-ring applications where the switching frequency is lower. The 55 mm width and 112 mm height fit a standard DIN-rail enclosure bay; depth is 115 mm including the arc chamber. ## Environmental and operating limits The contactor is rated for 50/60 Hz coils with a control voltage tolerance of 0.8 to 1.1 times rated at 50 Hz, and 0.85 to 1.1 at 60 Hz.","metaTitle":"Siemens SIRIUS 3RT1035-1AN60-1AA0 Power Contactor, S2, 22 kW","metaDescription":"Siemens SIRIUS 3RT1035-1AN60-1AA0 power contactor, size S2, rated 22 kW at 500 V AC-3, 55 mm wide, screw terminals, DIN rail mount. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"115 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"55 mm","at AC":"7 ... 20 ms","Height":"112 mm","Stranded":"2x (0.75 ... 25 mm²)","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","Arcing Time":"10 ... 15 ms","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","During Storage":"-55 ... +80 °C","Of The Terminal":"IP00","at AC-1 maximum":"1 200 1/h","at AC-2 maximum":"600 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.75 ... 16 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"200 V","at 500 V rated value":"22 kW","at 60 Hz rated value":"200 ... 220 V","at 690 V rated value":"11.4 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"18.5 kW","at AC-4 at 400 V rated value":"35 A","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"16 mm²","at 60 °C minimum permissible":"16 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"22 kW","at 690 V at 60 °C rated value":"66 kW","at AWG cables for main contacts":"2x (18 ... 2)","For Auxiliary And Control Circuit":"screw-type terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 63 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"fuse gL/gG: 125 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Thermal Short-Time Current Limited To 10 S":"400 A","Finely Stranded Without Core End Processing":"2x (0.75 ... 16 mm²)","apparent holding power of magnet coil at AC":"12.6 VA","apparent pick-up power of magnet coil at AC":"166 VA","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.71","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.37","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"0","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=144283&mlfb=3RT1035-1AN60-1AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1035-1AN60-1AA0/alternatives.json"},"ai":{"faq":[{"question":"What are the key power ratings for this contactor?","answer":"It is rated 22 kW at 500 V AC-3, 11.4 kW at 690 V AC-3, and 18.5 kW at 400 V AC-2. These cover standard squirrel-cage and wound-rotor motor switching."},{"question":"What wire sizes does the screw terminal accept?","answer":"Solid conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), max 2x (0.75 to 4 mm²). Stranded: 2x (0.75 to 25 mm²)."},{"question":"Will this contactor fit a panel designed for 3RT1036-1AB00?","answer":"The 3RT1035-1AN60-1AA0 is a size S2 frame (55 mm wide), while the 3RT1036-1AB00 is a different frame size. They are not mechanically interchangeable without checking the mounting footprint and terminal layout. The 3RT1035 is a smaller frame, so it will not drop into a panel cutout sized for the larger 3RT1036 without an adapter or rework."},{"question":"What compliance documentation is available for this part?","answer":"The evidence does not list specific compliance certificates (UL, CSA, CE, RoHS, REACH) for this order code. Standard Siemens SIRIUS contactors typically carry CE marking and are designed to IEC 60947-4-1, but verify the specific documentation with your Siemens channel partner for your jurisdiction."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1035-1AN60-1AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1035-1AN60-1AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}