{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1035-1AR60-1AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1035-1AR60-1AA0","canonicalUrl":"https://aoctrl.com/siemens/3RT1035-1AR60-1AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1035-1AR60-1AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, power contactor, Size S2, 3RT1035-1AR60-1AA0, 400 V 50 Hz, screw-type terminals, 55 mm width, IP20 front.","salesMarkdown":"The Siemens 3RT1035-1AR60-1AA0 is a SIRIUS power contactor in the Size S2 frame, rated for 400 V at 50 Hz and 400...440 V at 60 Hz. It is a current-production part, still in active manufacture. This contactor switches motor loads: at AC-2 duty (slip-ring motors, soft-start) it handles 18.5 kW at 400 V; at AC-3 duty (squirrel-cage motors, direct-on-line) it handles 22 kW at 500 V; at AC-4 duty (plugging, inching) it handles 11.4 kW at 690 V. Main current circuit terminals are screw-type, accepting solid conductors: 2x (0.5...1.5 mm²), 2x (0.75...2.5 mm²), max 2x (0.75...4 mm²). Stranded conductors accept 2x (0.75...25 mm²), and the combined solid-or-stranded range is 2x (0.75...16 mm²). This covers most panel wiring from control-circuit tails to motor feeders. ## Coil and auxiliary contact ratings Auxiliary contact ratings are given for DC switching: 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V. These are the make/break limits for the built-in aux contacts — useful for interlocking and PLC inputs. Maximum switching frequency varies by duty: 1,200 cycles/hour at AC-1 (resistive), 1,000 at AC-3, 600 at AC-2, and 300 at AC-4. The AC-4 limit reflects the heavier arc wear during plugging/reversing.","metaTitle":"Siemens 3RT1035-1AR60-1AA0 SIRIUS Power Contactor, Size S2,","metaDescription":"Siemens SIRIUS 3RT1035-1AR60-1AA0 power contactor, Size S2, 400V 50Hz, screw terminals, DIN rail mount. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"115 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"55 mm","at AC":"7 ... 20 ms","Height":"112 mm","Stranded":"2x (0.75 ... 25 mm²)","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","Arcing Time":"10 ... 15 ms","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","During Storage":"-55 ... +80 °C","Of The Terminal":"IP00","at AC-1 maximum":"1 200 1/h","at AC-2 maximum":"600 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.75 ... 16 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"400 V","at 500 V rated value":"22 kW","at 60 Hz rated value":"400 ... 440 V","at 690 V rated value":"11.4 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"18.5 kW","at AC-4 at 400 V rated value":"35 A","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"16 mm²","at 60 °C minimum permissible":"16 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"22 kW","at 690 V at 60 °C rated value":"66 kW","at AWG cables for main contacts":"2x (18 ... 2)","For Auxiliary And Control Circuit":"screw-type terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 63 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"fuse gL/gG: 125 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Thermal Short-Time Current Limited To 10 S":"400 A","Finely Stranded Without Core End Processing":"2x (0.75 ... 16 mm²)","apparent holding power of magnet coil at AC":"12.6 VA","apparent pick-up power of magnet coil at AC":"166 VA","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.71","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.37","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"0","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=56582&mlfb=3RT1035-1AR60-1AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1035-1AR60-1AA0/alternatives.json"},"ai":{"faq":[{"question":"What are the key motor ratings for 3RT1035-1AR60-1AA0?","answer":"At AC-3 duty it handles 22 kW at 500 V; at AC-2 duty it handles 18.5 kW at 400 V; at AC-4 duty it handles 11.4 kW at 690 V."},{"question":"Where can I buy 3RT1035-1AR60-1AA0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at the time of quote."},{"question":"What is the difference between 3RT1035-1AR60-1AA0 and 3RT5034-1AR60?","answer":"The 3RT5034-1AR60 is a Size S3 frame contactor with higher current ratings, so it is physically larger and will not drop into a panel wired for the Size S2 3RT1035-1AR60-1AA0 without rewiring and re-paneling. The 3RT1035-1AR60-1AA0 is the correct fit for Size S2 cutouts and buswork."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1035-1AR60-1AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1035-1AR60-1AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}