{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1035-1BM40","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1035-1BM40","canonicalUrl":"https://aoctrl.com/siemens/3RT1035-1BM40","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1035-1BM40","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS S2 power contactor, 3RT1035-1BM40, screw-type terminals, 22 kW at 500 V AC-3, snap-on 35 mm DIN rail mounting, IP20 front.","salesMarkdown":"The Siemens 3RT1035-1BM40 is a SIRIUS S2-frame power contactor — the workhorse for motor switching in control panels that already run on 35 mm DIN rail per EN 50022, with screw-and-snap-on mounting that drops into the same footprint as earlier S2 builds. Rated 22 kW at 500 V in AC-3 duty, it handles the standard induction motor curve for pumps, conveyors, and compressors without oversizing the contactor. At 55 mm wide and 130 mm deep, it leaves room alongside other S2 devices on the rail; side-by-side mounting is supported, so no derating for zero-gap packing in a tight enclosure. Solid wire accepts 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) and max 2x (0.75 to 4 mm²); stranded goes up to 2x 25 mm². The IP20 front and IP00 terminal area are typical for enclosed panel mounting — no special washdown rating, so keep it inside the cabinet.","metaTitle":"Siemens 3RT1035-1BM40 SIRIUS S2 Power Contactor, 22 kW at 50","metaDescription":"Siemens 3RT1035-1BM40 SIRIUS S2 power contactor, 22 kW at 500 V AC-3, screw terminals, snap-on 35 mm DIN rail. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"130 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"55 mm","at DC":"20 ... 25 ms","Height":"112 mm","Stranded":"2x (0.75 ... 25 mm²)","Arcing Time":"10 ... 15 ms","Rated Value":"220 V","On The Front":"IP20","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of The Terminal":"IP00","at AC-1 maximum":"1 200 1/h","at AC-2 maximum":"600 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Full-Scale Value":"1.1","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.75 ... 16 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 500 V rated value":"22 kW","at 690 V rated value":"11.4 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"18.5 kW","at AC-4 at 400 V rated value":"35 A","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"16 mm²","at 60 °C minimum permissible":"16 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"22 kW","at 690 V at 60 °C rated value":"66 kW","at AWG cables for main contacts":"2x (18 ... 2)","For Auxiliary And Control Circuit":"screw-type terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 63 A","closing power of magnet coil at DC":"13.3 W","holding power of magnet coil at DC":"13.3 W","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"fuse gL/gG: 125 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Thermal Short-Time Current Limited To 10 S":"400 A","Finely Stranded Without Core End Processing":"2x (0.75 ... 16 mm²)","Type Of Voltage Of The Control Supply Voltage":"DC","Required Spacing For Grounded Parts At The Side":"6 mm","contact rating of auxiliary contacts according to UL":"A600 / Q600","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"0","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=301775&mlfb=3RT1035-1BM40","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1035-1BM40/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1035-1BM40","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1035-1BM40 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}