{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1035-1QB44-3MA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1035-1QB44-3MA0","canonicalUrl":"https://aoctrl.com/siemens/3RT1035-1QB44-3MA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1035-1QB44-3MA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S2, 3RT1035-1QB44-3MA0, 22 kW at 500 V AC-3, screw-type terminals, 55 mm width, 179 mm depth.","salesMarkdown":"The 55 mm width and 179 mm depth determine the DIN-rail footprint. At 55 mm, it occupies three 18 mm module spaces — standard for an S2 frame. The 112 mm height leaves clearance for a typical 200 mm tall enclosure backplate. The minimum permissible cross-section at 40 °C is 16 mm², which governs the smallest wire you can terminate for full rated current — important when paralleling smaller conductors. Compliance documentation is in place: the substance prohibition date of 05/01/2012 aligns with RoHS and REACH requirements. No further compliance gaps to flag for EU or UKCA markets. ## Mechanical and Electrical Endurance Mechanical life is typical at 10,000,000 operations — this is the wear-out figure for the moving armature and springs under no-load cycling. Electrical life varies by duty: 1,200 operations per hour at AC-1 (resistive), 1,000 at AC-3 (motor running), and 300 at AC-4 (plugging/reversing).","metaTitle":"Siemens 3RT1035-1QB44-3MA0 SIRIUS Power Contactor, S2, 22 kW","metaDescription":"Siemens SIRIUS 3RT1035-1QB44-3MA0 power contactor, size S2, rated 22 kW at 500 V AC-3. Screw terminals, 55 mm wide, 179 mm deep. Active lifecycle, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"179 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"55 mm","at DC":"20 ... 25 ms","Height":"112 mm","Stranded":"2x (0.75 ... 25 mm²)","Arcing Time":"10 ... 15 ms","Rated Value":"24 V","On The Front":"IP20","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of The Terminal":"IP00","at AC-1 maximum":"1 200 1/h","at AC-2 maximum":"600 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Full-Scale Value":"1.1","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.75 ... 16 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 500 V rated value":"22 kW","at 690 V rated value":"11.4 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"18.5 kW","at AC-4 at 400 V rated value":"35 A","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"16 mm²","at 60 °C minimum permissible":"16 mm²","Design Of The Surge Suppressor":"with diode assemblies","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"22 kW","at 690 V at 60 °C rated value":"66 kW","at AWG cables for main contacts":"2x (18 ... 2)","For Auxiliary And Control Circuit":"screw-type terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 63 A","closing power of magnet coil at DC":"13.3 W","holding power of magnet coil at DC":"13.3 W","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"fuse gL/gG: 125 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Thermal Short-Time Current Limited To 10 S":"400 A","Finely Stranded Without Core End Processing":"2x (0.75 ... 16 mm²)","Type Of Voltage Of The Control Supply Voltage":"DC","Required Spacing For Grounded Parts At The Side":"6 mm","contact rating of auxiliary contacts according to UL":"A600 / Q600","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=218836&mlfb=3RT1035-1QB44-3MA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1035-1QB44-3MA0/alternatives.json"},"ai":{"faq":[{"question":"What are the key motor power ratings for this contactor?","answer":"In AC-3 duty, it is rated for 22 kW at 500 V and 11.4 kW at 690 V. At AC-2 at 400 V, it handles 18.5 kW. The AC-4 current rating is 35 A at 400 V."},{"question":"What are the physical dimensions for panel layout?","answer":"Width is 55 mm, height is 112 mm, and depth is 179 mm. It mounts on 35 mm DIN rail per EN 50022."},{"question":"What wire sizes does the screw terminal accept?","answer":"Solid conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), max 2x (0.75 to 4 mm²). Stranded: 2x (0.75 to 25 mm²). Minimum at 40 °C is 16 mm²."},{"question":"Can this contactor be mounted side-by-side with others?","answer":"Yes, side-by-side mounting is permitted without derating. This allows dense packing on the DIN rail."},{"question":"What compliance documentation is available?","answer":"The substance prohibition date of 05/01/2012 indicates RoHS and REACH compliance. Pollution degree 3 supports industrial environment certification."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1035-1QB44-3MA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1035-1QB44-3MA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}