{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1035-3AG14","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1035-3AG14","canonicalUrl":"https://aoctrl.com/siemens/3RT1035-3AG14","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1035-3AG14","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, 3RT1035-3AG14, S2 frame, screw-type terminals, 35 A AC-4 at 400 V, 18.5 kW AC-2 at 400 V, IP20 front, DIN EN 50022 rail mount.","salesMarkdown":"Rated for AC-4 duty at 35 A and 400 V, this contactor handles the severe switching conditions of motor reversing or plugging — where the contacts make and break locked-rotor current. For standard motor starting (AC-2), it carries 18.5 kW at 400 V, and at 500 V it delivers 22 kW, with a 690 V rating of 11.4 kW. The front face is IP20, while the terminals are IP00 — standard for panel-mounted contactors where the enclosure provides the overall protection. Pollution degree 3 suits industrial environments with conductive contamination. Side-by-side mounting is permitted, which simplifies multi-contactor panels. Main circuit screw terminals accept 2x (0.25 to 2.5 mm²) solid or 2x (0.75 to 25 mm²) stranded wire. The auxiliary circuit accepts 2x (0.75 to 16 mm²) solid or stranded. This range covers standard panel wiring from signal-level to motor power conductors.","metaTitle":"Siemens 3RT1035-3AG14 SIRIUS Power Contactor, 35 A AC-4, 18.","metaDescription":"Siemens 3RT1035-3AG14 SIRIUS power contactor, S2 frame, 35 A AC-4 at 400 V, 18.5 kW AC-2, screw terminals, IP20 front, DIN rail mount. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"164 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"55 mm","at AC":"7 ... 20 ms","Height":"112 mm","Stranded":"2x (0.75 ... 25 mm²)","at 60 Hz":"0.8 ... 1.1","Arcing Time":"10 ... 15 ms","On The Front":"IP20","1 Rated Value":"60 Hz","2 Rated Value":"50 Hz","During Storage":"-55 ... +80 °C","Of The Terminal":"IP00","at AC-1 maximum":"1 200 1/h","at AC-2 maximum":"600 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.75 ... 16 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"100 V","at 500 V rated value":"22 kW","at 60 Hz rated value":"110 V","at 690 V rated value":"11.4 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"18.5 kW","at AC-4 at 400 V rated value":"35 A","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"16 mm²","at 60 °C minimum permissible":"16 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"22 kW","at 690 V at 60 °C rated value":"66 kW","at AWG cables for main contacts":"2x (18 ... 2)","For Auxiliary And Control Circuit":"spring-loaded terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 63 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"fuse gL/gG: 125 A","at AWG cables for auxiliary contacts":"2x (24 ... 14)","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Thermal Short-Time Current Limited To 10 S":"400 A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","apparent holding power of magnet coil at AC":"12.6 VA","apparent pick-up power of magnet coil at AC":"166 VA","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.71","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.37","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=524319&mlfb=3RT1035-3AG14","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1035-3AG14/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RT1035-3AG14?","answer":"This part is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — both are confirmed at quote time."},{"question":"What is 3RT1035-3AG14's depth?","answer":"The depth is 164 mm."},{"question":"What solid wire sizes does the main circuit accept?","answer":"The main circuit screw terminals accept 2x (0.25 to 2.5 mm²) solid wire."},{"question":"Will 3RT1035-3AG14 drop into a panel specified around 3RT1044-1FB46 without rewiring?","answer":"The 3RT1035-3AG14 is a smaller S2-frame contactor compared to the S3-frame 3RT1044-1FB46. The mounting rail and terminal layout differ — expect to rework the panel layout and wiring."},{"question":"What compliance documentation does Siemens provide for 3RT1035-3AG14?","answer":"Siemens typically provides RoHS and REACH declarations, plus UL and IEC certifications. Specific documents are available on request with the RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1035-3AG14","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1035-3AG14 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}