{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1036-1AG60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1036-1AG60","canonicalUrl":"https://aoctrl.com/siemens/3RT1036-1AG60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1036-1AG60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S2, order code 3RT1036-1AG60, 22 kW at AC-2 400 V, screw-type terminals, IP20 front, snap-on DIN rail mounting.","salesMarkdown":"## Siemens 3RT1036-1AG60 SIRIUS Power Contactor At AC-3 duty (squirrel-cage motors), the rating shifts — the 500 V line shows 30 kW, and at 690 V it delivers 11.4 kW, so the buyer needs to match the utilization category to the load type, not just the highest kW number. Terminals are screw-type on the main current circuit. Solid wire accepts 2x (0.5...1.5 mm²), 2x (0.75...2.5 mm²), and up to 2x (0.75...4 mm²). That range covers control wiring through motor power tails without needing adapter lugs. ## Duty Ratings and Switching Life The AC-2 rating at 400 V (22 kW) is the headline figure for this contactor, but the AC-3 and AC-4 ratings tell the real switching story. At AC-3 (squirrel-cage motor starting), the maximum switching rate is 800 operations per hour; at AC-4 (plugging or inching), it drops to 300 per hour. Coil operating range is 0.8...1.1 at 50 Hz and 0.85...1.1 at 60 Hz. Arcing time runs 10...15 ms, with a total make/break time of 7...20 ms at AC. That's fast enough for most motor-starting sequences but not for semiconductor-grade switching — this is an electromechanical contactor, not a solid-state relay.","metaTitle":"Siemens 3RT1036-1AG60 SIRIUS Power Contactor, S2, 22 kW AC-2","metaDescription":"Siemens 3RT1036-1AG60 SIRIUS power contactor, size S2, rated 22 kW at AC-2 400 V. Screw terminals, IP20 front, snap-on DIN rail. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"115 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"55 mm","at AC":"7 ... 20 ms","Height":"112 mm","Stranded":"2x (0.75 ... 25 mm²)","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","Arcing Time":"10 ... 15 ms","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","During Storage":"-55 ... +80 °C","Of The Terminal":"IP00","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"400 1/h","at AC-3 maximum":"800 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.75 ... 16 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"100 V","at 500 V rated value":"30 kW","at 60 Hz rated value":"100 ... 110 V","at 690 V rated value":"11.4 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"22 kW","at AC-4 at 400 V rated value":"41 A","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"16 mm²","at 60 °C minimum permissible":"16 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"22 kW","at 690 V at 60 °C rated value":"66 kW","at AWG cables for main contacts":"2x (18 ... 2)","For Auxiliary And Control Circuit":"screw-type terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 80 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"fuse gL/gG: 160 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Thermal Short-Time Current Limited To 10 S":"400 A","Finely Stranded Without Core End Processing":"2x (0.75 ... 16 mm²)","apparent holding power of magnet coil at AC":"12.6 VA","apparent pick-up power of magnet coil at AC":"166 VA","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.71","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.37","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"0","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$360.05","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=278352&mlfb=3RT1036-1AG60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1036-1AG60/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the 3RT1036-1AG60?","answer":"Rated 22 kW at AC-2 400 V, 30 kW at AC-3 500 V, and 11.4 kW at AC-3 690 V. Mechanical life is 10 million operations typical. Maximum switching rate is 800 operations per hour at AC-3."},{"question":"How do I get pricing and availability for the 3RT1036-1AG60?","answer":"Submit an RFQ through this listing. The part is sourced to order through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is the closest functional alternative to the 3RT1036-1AG60?","answer":"The 3RT5036-1AP00 is a size S2 contactor in the same SIRIUS family, but it uses spring-type terminals instead of screw terminals. The 3RT1036-1AG60 uses screw-type terminals on the main circuit. If your panel is wired for screw terminals, the 3RT5036-1AP00 would require a terminal adapter or re-termination."},{"question":"Will the 3RT1036-1AG60 drop into a panel specified for the 3RT5036-1AP00?","answer":"The mounting footprint (S2, 55 mm width, snap-on DIN rail) is identical. The difference is the terminal type: screw on the 3RT1036-1AG60 versus spring-cage on the 3RT5036-1AP00. If the panel is wired with ferruled stranded conductors, the spring-cage terminal may be faster to terminate, but the screw terminal accepts the same wire ranges and is more tolerant of solid wire without ferrules."},{"question":"What compliance documentation does Siemens provide for the 3RT1036-1AG60?","answer":"The contactor carries IP20 front / IP00 terminal protection and is rated for pollution degree 3 per IEC 60947. Standard Siemens documentation includes the declaration of conformity for CE/UKCA, and the product is designed for use in industrial control panels per UL/CSA requirements. Specific RoHS and REACH declarations are available through the manufacturer's documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1036-1AG60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1036-1AG60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}