{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1036-1AL24-ZW96","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1036-1AL24-ZW96","canonicalUrl":"https://aoctrl.com/siemens/3RT1036-1AL24-ZW96","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1036-1AL24-ZW96","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, 3RT1036-1AL24-ZW96, S2 frame size, screw-type terminals, 22 kW at 400 V AC-2, 30 kW at 500 V, 55 mm width, 112 mm height, 164 mm depth.","salesMarkdown":"Rated for 22 kW at 400 V under AC-2 duty (slip-ring motor starting) and 30 kW at 500 V, this contactor handles moderate motor loads common in conveyor, pump, and fan applications. The AC-3 rating at 400 V, though not explicitly stated in this variant's spec, is typically in the same power class for squirrel-cage motors. The AC-2 rating of 22 kW at 400 V is the headline motor-switching figure. If your load is a standard squirrel-cage motor (AC-3), this contactor is still applicable but you should confirm the AC-3 current rating from the full datasheet. The 30 kW at 500 V rating gives headroom for higher-voltage installations common in 480 V North American systems. Mechanical life is typical at 10,000,000 operations. Wire capacity is generous: solid conductors from 0.5 to 4 mm² per terminal (2x), and stranded up to 25 mm² (2x). This covers most motor feeder cables up to 6 AWG. Side-by-side mounting is permitted. S2 frame width is 55 mm; depth is 164 mm. Terminals are screw-type, so expect to use a Pozidriv or slotted screwdriver for termination. The solid/stranded wire ranges allow for either direct connection or ferruled ends. For the coil connections (24 V DC rated at 10 A making current), use at least 1.5 mm² stranded wire to avoid voltage drop on long runs from the PLC output card.","metaTitle":"Siemens 3RT1036-1AL24-ZW96 SIRIUS Power Contactor, S2 Frame,","metaDescription":"Siemens SIRIUS 3RT1036-1AL24-ZW96 power contactor, S2 frame size. Rated 22 kW at 400 V AC-2, 30 kW at 500 V. Screw terminals, DIN rail mount. Current lifecycle stage. Sourced to RF","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"164 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"55 mm","at AC":"7 ... 20 ms","Height":"112 mm","Stranded":"2x (0.75 ... 25 mm²)","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","Arcing Time":"10 ... 15 ms","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","During Storage":"-55 ... +80 °C","Of The Terminal":"IP00","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"400 1/h","at AC-3 maximum":"800 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.75 ... 16 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"230 V","at 500 V rated value":"30 kW","at 60 Hz rated value":"230 V","at 690 V rated value":"11.4 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"22 kW","at AC-4 at 400 V rated value":"41 A","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"16 mm²","at 60 °C minimum permissible":"16 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"22 kW","at 690 V at 60 °C rated value":"66 kW","at AWG cables for main contacts":"2x (18 ... 2)","For Auxiliary And Control Circuit":"screw-type terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 80 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"fuse gL/gG: 160 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Thermal Short-Time Current Limited To 10 S":"400 A","Finely Stranded Without Core End Processing":"2x (0.75 ... 16 mm²)","apparent holding power of magnet coil at AC":"15 VA","apparent pick-up power of magnet coil at AC":"170 VA","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.76","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.35","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=413931&mlfb=3RT1036-1AL24-ZW96","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1036-1AL24-ZW96/alternatives.json"},"ai":{"faq":[{"question":"What are the key dimensions for panel fit?","answer":"Width is 55 mm, height is 112 mm, and depth is 164 mm. This is the S2 frame size. Mounts on 35 mm DIN rail per DIN EN 50022, and side-by-side mounting is allowed with no spacing required."},{"question":"What wire sizes does this contactor accept?","answer":"Solid conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), max 2x (0.75 to 4 mm²). Stranded conductors: 2x (0.75 to 25 mm²). The main current circuit uses screw-type terminals."},{"question":"What compliance documentation is available?","answer":"The product carries the SIRIUS brand designation. Standard compliance documentation includes CE marking for the European market. For specific UL, CSA, or RoHS declarations, these are typically available from the manufacturer upon request or through the product documentation portal. The pollution degree is rated 3 for industrial environments."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1036-1AL24-ZW96","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1036-1AL24-ZW96 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}