{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1036-1AN60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1036-1AN60","canonicalUrl":"https://aoctrl.com/siemens/3RT1036-1AN60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1036-1AN60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, 3RT1036-1AN60, S2 size, screw-type terminals, 30 kW at 500 V, 22 kW at AC-2 400 V, snap-on 35 mm DIN rail mount.","salesMarkdown":"It is rated for 30 kW at 500 V and 22 kW at AC-2 duty at 400 V, which covers the bulk of standard induction motor applications in that power band. The 115 mm depth leaves clearance for wiring and auxiliary blocks. The AC-3 rating (not explicitly listed here but implied by the S2 frame class) would cover standard squirrel-cage motors, where switching occurs at starting current only. Wiring terminals accept solid conductors up to 4 mm² per clamp (2x 0.75...4 mm² max) and stranded up to 25 mm² (2x 0.75...25 mm²), which covers the power feed for a 22 kW motor on a 4–6 mm² cable. The screw-type main terminals are straightforward for panel builders — no special tooling needed. The IP20 front protection means the terminals are finger-safe once wired, but the body itself is IP00 (open), so it must live inside an enclosure. For a BOM line that was specified around the 3RT1036-1AB00 (the DC-coil variant), this 1AN60 (AC-coil, 50/60 Hz) will not drop in without a coil voltage change — the mechanical footprint and terminal layout are identical, but the coil driver circuit must match. If your panel was built for 24 VDC coil control, the 1AN60 won't work without rewiring the coil supply. Side-by-side mounting is permitted, which saves panel width when ganging multiple contactors for a star-delta or reversing starter.","metaTitle":"Siemens 3RT1036-1AN60 SIRIUS Power Contactor, 30 kW at 500 V","metaDescription":"Siemens 3RT1036-1AN60 SIRIUS power contactor, S2 size. Rated 30 kW at 500 V, 22 kW at AC-2 400 V. Screw terminals, snap-on DIN rail mount. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"115 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"55 mm","at AC":"7 ... 20 ms","Height":"112 mm","Stranded":"2x (0.75 ... 25 mm²)","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","Arcing Time":"10 ... 15 ms","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","During Storage":"-55 ... +80 °C","Of The Terminal":"IP00","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"400 1/h","at AC-3 maximum":"800 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.75 ... 16 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"200 V","at 500 V rated value":"30 kW","at 60 Hz rated value":"200 ... 220 V","at 690 V rated value":"11.4 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"22 kW","at AC-4 at 400 V rated value":"41 A","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"16 mm²","at 60 °C minimum permissible":"16 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"22 kW","at 690 V at 60 °C rated value":"66 kW","at AWG cables for main contacts":"2x (18 ... 2)","For Auxiliary And Control Circuit":"screw-type terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 80 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"fuse gL/gG: 160 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Thermal Short-Time Current Limited To 10 S":"400 A","Finely Stranded Without Core End Processing":"2x (0.75 ... 16 mm²)","apparent holding power of magnet coil at AC":"12.6 VA","apparent pick-up power of magnet coil at AC":"166 VA","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.71","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.37","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"0","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=109882&mlfb=3RT1036-1AN60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1036-1AN60/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source to the 3RT1036-1AN60?","answer":"The 3RT1036-1AB00 is the same S2 frame and mechanical footprint, but it uses a DC coil (24 VDC typical) instead of the AC coil (50/60 Hz) on the 1AN60. The power switching ratings are identical; the difference is the coil supply. If your panel has 24 VDC control, the 1AB00 is a drop-in; if it has AC control, the 1AN60 is the correct part."},{"question":"What is the depth of the 3RT1036-1AN60?","answer":"The depth is listed as 115 mm."},{"question":"What solid conductor sizes does the 3RT1036-1AN60 accept?","answer":"The screw terminals accept 2x (0.5...1.5 mm²), 2x (0.75...2.5 mm²), and max. 2x (0.75...4 mm²) solid conductors."},{"question":"Will the 3RT1036-1AN60 drop into a panel specified for the 3RT1036-1AB00 without rewiring?","answer":"Mechanically yes — same S2 frame, same DIN rail footprint, same terminal layout. Electrically no, unless the coil voltage matches. The 1AN60 uses an AC coil (50/60 Hz, 200...220 V or 200 V depending on the variant); the 1AB00 uses a DC coil. If the panel was wired for 24 VDC coil control, the 1AN60 will not operate without changing the coil supply circuit."},{"question":"What compliance documentation does Siemens provide for the 3RT1036-1AN60?","answer":"The evidence does not list specific compliance documents (RoHS, REACH, UL, IEC) for this order code. Standard Siemens SIRIUS contactors typically carry CE, UL, and CSA certifications, but you should verify the exact declaration for your shipment against the nameplate markings."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1036-1AN60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1036-1AN60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}