{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1036-1AP00-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1036-1AP00-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RT1036-1AP00-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1036-1AP00-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S2, 3RT1036-1AP00-ZX95, 22 kW at 400 V AC-2, screw-type terminals, 55 mm width, DIN rail mount.","salesMarkdown":"Rated for 50 Hz operation, it delivers 22 kW in AC-2 duty at 400 V — that's the standard rating for slip-ring motor starting where the contactor opens under load. At 500 V it handles 30 kW, and at 690 V it's rated 11.4 kW. For the heavy inching/jogging duty of AC-4, it's rated 41 A at 400 V. The AC-3 motor-switching rating sits at 800 operations per hour maximum, while AC-4 allows 300 per hour. The coil draws 10 A at 24 V rated value, 6 A at 230 V, and 3 A at 400 V — these are the holding currents, not the pick-up surge. That matters for coordination with upstream short-circuit protection: the arc energy has to clear within the breaker's let-through window. Main power terminals are screw-type, accepting solid conductors 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), and up to 2x (0.75 to 4 mm²). For stranded wire, the range goes 2x (0.75 to 25 mm²). The combined solid-or-stranded rating covers 2x (0.75 to 16 mm²). At 40 °C ambient, the minimum permissible conductor size is 16 mm² — that's the thermal derating floor, not a wiring recommendation. The contactor supports side-by-side mounting without derating, which saves rail space when grouping multiple contactors in a motor control center. At 55 mm wide, 112 mm tall, and 115 mm deep, it fits standard 55 mm pitch DIN-rail layouts. ## Sourcing note This is a stocked line item in the independent distribution channel. The 3RT1036-1AP00-ZX95 is the exact order code for the screw-terminal, 24 V DC coil variant; if your BOM specifies a different coil voltage or cage-clamp terminals, the 3RT5036-1AP00 (screw, 24 V DC) or 3RT5036-1AB00 (cage-clamp, 24 V DC) are the direct siblings in the same S2 frame.","metaTitle":"Siemens 3RT1036-1AP00-ZX95 SIRIUS Power Contactor, 22 kW AC-","metaDescription":"Siemens 3RT1036-1AP00-ZX95 SIRIUS power contactor, size S2. Rated 22 kW at 400 V AC-2, 30 kW at 500 V. Screw terminals, DIN rail mount. Active lifecycle. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"115 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"55 mm","at AC":"7 ... 20 ms","Height":"112 mm","Stranded":"2x (0.75 ... 25 mm²)","at 50 Hz":"0.8 ... 1.1","Arcing Time":"10 ... 15 ms","On The Front":"IP20","1 Rated Value":"50 Hz","During Storage":"-55 ... +80 °C","Of The Terminal":"IP00","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"400 1/h","at AC-3 maximum":"800 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.75 ... 16 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"230 V","at 500 V rated value":"30 kW","at 690 V rated value":"11.4 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"22 kW","at AC-4 at 400 V rated value":"41 A","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"16 mm²","at 60 °C minimum permissible":"16 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"22 kW","at 690 V at 60 °C rated value":"66 kW","at AWG cables for main contacts":"2x (18 ... 2)","For Auxiliary And Control Circuit":"screw-type terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 80 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"fuse gL/gG: 160 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Thermal Short-Time Current Limited To 10 S":"400 A","Finely Stranded Without Core End Processing":"2x (0.75 ... 16 mm²)","apparent holding power of magnet coil at AC":"12.5 VA","apparent pick-up power of magnet coil at AC":"145 VA","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.79","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.36","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"0","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=344228&mlfb=3RT1036-1AP00-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1036-1AP00-ZX95/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source for 3RT1036-1AP00-ZX95?","answer":"The 3RT5036-1AP00 is the direct sibling in the same S2 frame with screw terminals and a 24 V DC coil. It shares the same mounting footprint and ratings, so it drops into a panel specified around the 3RT1036-1AP00-ZX95 without rewiring."},{"question":"What compliance documentation does this brand provide for 3RT1036-1AP00-ZX95?","answer":"The part meets RoHS compliance with a substance prohibition date of 05/01/2012, and is rated for pollution degree 3 per IEC 60947-1. Standard Siemens SIRIUS documentation includes the declaration of conformity and the datasheet."},{"question":"How do I get current pricing and availability for 3RT1036-1AP00-ZX95?","answer":"This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1036-1AP00-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1036-1AP00-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}