{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1036-1AP08-0MA0-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1036-1AP08-0MA0-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RT1036-1AP08-0MA0-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1036-1AP08-0MA0-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S2, 55 mm width, screw terminals, 230 V 50 Hz coil, AC-3 rated at 800 operations per hour, 22 kW at 400 V AC-2.","salesMarkdown":"The Siemens 3RT1036-1AP08-0MA0-ZX95 is a SIRIUS power contactor in size S2, 55 mm wide, 112 mm tall, 164 mm deep — a compact footprint for a 22 kW motor at 400 V AC-2 duty. Screw terminals accept solid wire up to 4 mm² (two per clamp) or stranded up to 25 mm² (two per clamp). Coil is 230 V 50 Hz, with a rated operating range of 0.8 to 1.1 times nominal at 50 Hz. AC-3 switching (motor start/run) is rated at 800 operations per hour, AC-1 (resistive) at 1000 ops/h, AC-4 (plugging/inching) at 300 ops/h. The front panel is IP20; the terminal area is IP00 — typical for panel-mount contactors where the enclosure provides the overall protection. Pollution degree 3, operating temperature -25 to +60 °C, storage -55 to +80 °C. ## Wiring and integration Main circuit terminals: screw-type, accepting solid 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), max 2x (0.75 to 4 mm²), and stranded 2x (0.75 to 25 mm²). For solid or stranded, 2x (0.75 to 16 mm²) is also listed. At 40 °C, minimum permissible conductor size is 16 mm². Arcing time is 7 to 20 ms at AC, 10 to 15 ms typical. Auxiliary contact ratings: 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V, 6 A at 230 V, 3 A at 400 V.","metaTitle":"Siemens 3RT1036-1AP08-0MA0-ZX95 SIRIUS Power Contactor, S2,","metaDescription":"Siemens SIRIUS power contactor 3RT1036-1AP08-0MA0-ZX95, size S2, 55 mm width, screw terminals, 230 V 50 Hz coil, AC-3 rated at 800 ops/h. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"164 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"55 mm","at AC":"7 ... 20 ms","Height":"112 mm","Stranded":"2x (0.75 ... 25 mm²)","at 50 Hz":"0.8 ... 1.1","Arcing Time":"10 ... 15 ms","On The Front":"IP20","1 Rated Value":"50 Hz","During Storage":"-55 ... +80 °C","Of The Terminal":"IP00","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"400 1/h","at AC-3 maximum":"800 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.75 ... 16 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"230 V","at 500 V rated value":"30 kW","at 690 V rated value":"11.4 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"22 kW","at AC-4 at 400 V rated value":"41 A","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"16 mm²","at 60 °C minimum permissible":"16 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"22 kW","at 690 V at 60 °C rated value":"66 kW","at AWG cables for main contacts":"2x (18 ... 2)","For Auxiliary And Control Circuit":"screw-type terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 80 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"fuse gL/gG: 160 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Thermal Short-Time Current Limited To 10 S":"400 A","Finely Stranded Without Core End Processing":"2x (0.75 ... 16 mm²)","apparent holding power of magnet coil at AC":"12.5 VA","apparent pick-up power of magnet coil at AC":"145 VA","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.79","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.36","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=220680&mlfb=3RT1036-1AP08-0MA0-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1036-1AP08-0MA0-ZX95/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source for 3RT1036-1AP08-0MA0-ZX95?","answer":"The 3RT5036-1AP00 is a direct functional peer — same size S2, same coil voltage, same screw terminals — but check the terminal wiring capacity and auxiliary contact configuration against your panel design before substituting."},{"question":"What compliance documentation does this contactor carry?","answer":"RoHS compliance is dated 05/01/2012. The part is a Siemens SIRIUS power contactor with IP20 front protection; full IEC/UL certification details are available on the manufacturer's declaration."},{"question":"How is 3RT1036-1AP08-0MA0-ZX95 quoted for volume purchases?","answer":"Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time. Volume pricing is negotiable."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1036-1AP08-0MA0-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1036-1AP08-0MA0-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}