{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1036-1AT60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1036-1AT60","canonicalUrl":"https://aoctrl.com/siemens/3RT1036-1AT60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1036-1AT60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, S2 frame, screw-type terminals, 22 kW AC-2 at 400 V, 41 A AC-4, IP20 front, DIN EN 50022 rail mount.","salesMarkdown":"## Part identification and mounting ## Motor switching ratings and duty cycles For AC-4 (inching/plugging) the contactor carries 41 A at 400 V, which is the higher thermal stress case. Maximum switching rates are 400 cycles/hour for AC-2 and 300 cycles/hour for AC-4, so this part is not intended for high-speed jogging applications. ## Coil and auxiliary ratings The coil operates at 24 V rated value drawing 10 A — this is the inrush current for the solenoid, not the holding current. At 230 V rated value the auxiliary contacts carry 6 A, suitable for pilot duty in control circuits. The contactor's mechanical life is typically 10 million operations, with electrical life dependent on the switching category and load current. The front of the contactor is rated IP20 (finger-safe terminals), while the terminal area itself is IP00 — panel builders must account for this in the enclosure design. RoHS compliance is evidenced by the substance prohibition date of 05/01/2012.","metaTitle":"Siemens 3RT1036-1AT60 SIRIUS Power Contactor, S2 Frame, 22 k","metaDescription":"Siemens 3RT1036-1AT60 SIRIUS power contactor, S2 frame, 22 kW AC-2 at 400 V, 41 A AC-4. Screw terminals, IP20 front, DIN rail mount. Current production. Sourced to order against RF","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"115 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"55 mm","at AC":"7 ... 20 ms","Height":"112 mm","Stranded":"2x (0.75 ... 25 mm²)","at 60 Hz":"0.8 ... 1.1","Arcing Time":"10 ... 15 ms","On The Front":"IP20","1 Rated Value":"60 Hz","During Storage":"-55 ... +80 °C","Of The Terminal":"IP00","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"400 1/h","at AC-3 maximum":"800 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.75 ... 16 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 500 V rated value":"30 kW","at 60 Hz rated value":"600 V","at 690 V rated value":"11.4 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"22 kW","at AC-4 at 400 V rated value":"41 A","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"16 mm²","at 60 °C minimum permissible":"16 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"22 kW","at 690 V at 60 °C rated value":"66 kW","at AWG cables for main contacts":"2x (18 ... 2)","For Auxiliary And Control Circuit":"screw-type terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 80 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"fuse gL/gG: 160 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Thermal Short-Time Current Limited To 10 S":"400 A","Finely Stranded Without Core End Processing":"2x (0.75 ... 16 mm²)","apparent holding power of magnet coil at AC":"12.6 VA","apparent pick-up power of magnet coil at AC":"166 VA","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.71","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.37","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"0","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=109161&mlfb=3RT1036-1AT60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1036-1AT60/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RT1036-1AT60 and how do I get a price?","answer":"This part is sourced through independent industrial distribution channels. Submit an RFQ for current pricing and availability confirmation at the time of your order."},{"question":"What is 3RT1036-1AT60's listed depth?","answer":"The overall depth is 115 mm, with a width of 55 mm and height of 112 mm, fitting the S2 frame footprint."},{"question":"What compliance documentation does this brand provide for 3RT1036-1AT60?","answer":"The manufacturer provides RoHS compliance with a substance prohibition date of 05/01/2012. The contactor is designed to IEC 60947-4-1 with pollution degree 3. REACH and UL documentation should be requested at time of order for your specific jurisdiction."},{"question":"Will 3RT1036-1AT60 drop into a panel specified around 3RT5036-1AP00 without rewiring?","answer":"Both are S2 frame contactors with the same mounting footprint on 35 mm DIN rail per EN 50022. The 3RT1036-1AT60 uses screw-type terminals for the main circuit, while the 3RT5036 series uses spring-cage terminals. If the panel was wired for screw terminals, the 3RT1036-1AT60 is a direct mechanical fit; if the panel uses spring-cage connectors, the terminal type differs and wiring adaptation is required."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1036-1AT60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1036-1AT60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}