{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1036-1AV60-0UA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1036-1AV60-0UA0","canonicalUrl":"https://aoctrl.com/siemens/3RT1036-1AV60-0UA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1036-1AV60-0UA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S2, 3RT1036-1AV60-0UA0, 55 mm width, screw-type terminals, 30 kW at 500 V, 41 A AC-4 at 400 V.","salesMarkdown":"The 3RT1036-1AV60-0UA0: Rated for 30 kW at 500 V, this contactor handles a typical 3-phase induction motor of that power on a 500 V line — common in European and some North American industrial installations. AC-2 at 400 V is rated at 22 kW, covering slip-ring motor applications. The 60 Hz rated value of 480 V confirms suitability for 480 V systems at 60 Hz. ## Wiring and terminal details Solid wire accepts 2x (0.5 to 1.5 mm²) and 2x (0.75 to 2.5 mm²), with a maximum of 2x (0.75 to 4 mm²). At 40 °C, the minimum permissible cross-section is 16 mm² — important for derating in warm panels. The solid or stranded range covers 2x (0.75 to 16 mm²). These ranges give flexibility for both control wiring and power conductors. ## Sourcing and fit considerations The 115 mm depth and 112 mm height fit standard 200 mm deep enclosures. If your panel was specified around the 3RT1036-1AB00, check the coil voltage — this variant's coil data is not in this record, but the mechanical footprint and terminal layout are identical across the S2 frame, so no rewiring is needed for the power circuit.","metaTitle":"Siemens 3RT1036-1AV60-0UA0 SIRIUS Power Contactor, S2, 55mm","metaDescription":"Siemens SIRIUS 3RT1036-1AV60-0UA0 power contactor, size S2, 55mm width, rated 30 kW at 500 V, 41 A AC-4 at 400 V. Current production. Screw terminals, DIN rail mount.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"115 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"55 mm","at AC":"7 ... 20 ms","Height":"112 mm","Stranded":"2x (0.75 ... 25 mm²)","at 60 Hz":"0.8 ... 1.1","Arcing Time":"10 ... 15 ms","On The Front":"IP20","1 Rated Value":"60 Hz","During Storage":"-55 ... +80 °C","Of The Terminal":"IP00","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"400 1/h","at AC-3 maximum":"800 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.75 ... 16 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 500 V rated value":"30 kW","at 60 Hz rated value":"480 V","at 690 V rated value":"11.4 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"22 kW","at AC-4 at 400 V rated value":"41 A","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"16 mm²","at 60 °C minimum permissible":"16 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"22 kW","at 690 V at 60 °C rated value":"66 kW","at AWG cables for main contacts":"2x (18 ... 2)","For Auxiliary And Control Circuit":"screw-type terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 80 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"fuse gL/gG: 160 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Thermal Short-Time Current Limited To 10 S":"400 A","Finely Stranded Without Core End Processing":"2x (0.75 ... 16 mm²)","apparent holding power of magnet coil at AC":"12.6 VA","apparent pick-up power of magnet coil at AC":"166 VA","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.71","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.37","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"0","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=330811&mlfb=3RT1036-1AV60-0UA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1036-1AV60-0UA0/alternatives.json"},"ai":{"faq":[{"question":"What are the key dimensions for panel fit?","answer":"Width is 55 mm, depth is 115 mm, and height is 112 mm. It mounts on 35 mm DIN rail per DIN EN 50022 and allows side-by-side mounting."},{"question":"What wire sizes does the screw terminal accept?","answer":"Solid wire: 2x (0.5 to 1.5 mm²) and 2x (0.75 to 2.5 mm²), max 2x (0.75 to 4 mm²). Stranded: 2x (0.75 to 25 mm²). At 40 °C, minimum 16 mm² is required."},{"question":"What compliance documentation is available?","answer":"RoHS compliance date is May 1, 2012. The part carries IP20 front protection and IP00 terminal protection, with pollution degree 3 rating for industrial environments."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1036-1AV60-0UA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1036-1AV60-0UA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}