{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1036-3AT60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1036-3AT60","canonicalUrl":"https://aoctrl.com/siemens/3RT1036-3AT60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1036-3AT60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, 3RT1036-3AT60, size S2, screw-type terminals, 22 kW at AC-2 400 V, 41 A at AC-4 400 V.","salesMarkdown":"Rated for 22 kW at AC-2 400 V and 41 A at AC-4 400 V, this contactor handles moderate motor starting and plugging/reversing duties. The AC-2 rating covers wound-rotor motors; Dimensions are 115 mm depth, 55 mm width, 112 mm height — fits standard S2 contactor footprints. Side-by-side mounting is permitted, saving panel width when multiple contactors are ganged. Terminals accept 2x (0.25…2.5 mm²) solid or 2x (0.75…25 mm²) stranded wire for the main circuit; the auxiliary circuit uses 2x (0.75…16 mm²). IP20 on the front, IP00 at the terminals — enclosure required for terminal protection. Rated operational voltage is 600 V at 60 Hz. Power ratings include 30 kW at 500 V and 11.4 kW at 690 V, giving flexibility across common industrial voltage levels. Maximum switching rates vary by duty: 1000 cycles/h at AC-1, 800 at AC-3, 400 at AC-2, 300 at AC-4. Substance prohibitance date of 05/01/2012 aligns with RoHS compliance. The contactor carries the SIRIUS brand and is designed for global panel builds.","metaTitle":"Siemens 3RT1036-3AT60 SIRIUS Power Contactor, 22 kW AC-2, 41","metaDescription":"Siemens 3RT1036-3AT60 SIRIUS power contactor, size S2. Rated 22 kW at AC-2 400 V, 41 A at AC-4 400 V. Current lifecycle stage. Screw terminals, DIN-rail mount. RFQ for sourcing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"115 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"55 mm","at AC":"7 ... 20 ms","Height":"112 mm","Stranded":"2x (0.75 ... 25 mm²)","at 60 Hz":"0.8 ... 1.1","Arcing Time":"10 ... 15 ms","On The Front":"IP20","1 Rated Value":"60 Hz","During Storage":"-55 ... +80 °C","Of The Terminal":"IP00","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"400 1/h","at AC-3 maximum":"800 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.75 ... 16 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 500 V rated value":"30 kW","at 60 Hz rated value":"600 V","at 690 V rated value":"11.4 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"22 kW","at AC-4 at 400 V rated value":"41 A","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"16 mm²","at 60 °C minimum permissible":"16 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"22 kW","at 690 V at 60 °C rated value":"66 kW","at AWG cables for main contacts":"2x (18 ... 2)","For Auxiliary And Control Circuit":"spring-loaded terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 80 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"fuse gL/gG: 160 A","at AWG cables for auxiliary contacts":"2x (24 ... 14)","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Thermal Short-Time Current Limited To 10 S":"400 A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","apparent holding power of magnet coil at AC":"12.6 VA","apparent pick-up power of magnet coil at AC":"166 VA","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.71","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.37","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"0","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=389020&mlfb=3RT1036-3AT60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1036-3AT60/alternatives.json"},"ai":{"faq":[{"question":"What are the key motor ratings for the 3RT1036-3AT60?","answer":"It is rated for 22 kW at AC-2 400 V and 41 A at AC-4 400 V. At 500 V it handles 30 kW; at 690 V it handles 11.4 kW."},{"question":"What is the mounting and terminal arrangement?","answer":"It snaps onto a 35 mm DIN rail per DIN EN 50022. Main circuit uses screw terminals accepting 2x (0.25…2.5 mm²) solid or 2x (0.75…25 mm²) stranded. Side-by-side mounting is allowed."},{"question":"What compliance documentation is available?","answer":"The substance prohibitance date of 05/01/2012 indicates RoHS compliance. The SIRIUS brand typically provides CE, UL, and CSA certifications; check the specific variant for exact marks."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1036-3AT60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1036-3AT60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}