{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1036-3AV60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1036-3AV60","canonicalUrl":"https://aoctrl.com/siemens/3RT1036-3AV60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1036-3AV60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, Size S2, order code 3RT1036-3AV60, screw-type terminals, 55 mm width, AC-2 rated 22 kW at 400 V, AC-4 rated 41 A at 400 V, IP20 front / IP00 terminals.","salesMarkdown":"The headline motor ratings tell you where this contactor fits: AC-2 duty at 400 V delivers 22 kW for slip-ring or wound-rotor motors, while the AC-4 rating of 41 A at 400 V covers plugging and inching duty cycles where the contactor makes and breaks stalled rotor current. At 500 V the contactor is rated for 30 kW, and at 690 V it handles 11.4 kW — useful for 690 V mining or industrial networks where step-down transformers aren't in the path. The switching frequency limits are also worth noting: 800 operations per hour at AC-3, but only 300 per hour at AC-4, which lines up with the heavier arc duty of plugging stops. Operating temperature range is -25 to +60 °C, storage from -55 to +80 °C, and the pollution degree is rated 3 — meaning the contactor is designed for conductive pollution or dry non-conductive pollution that becomes conductive through condensation, which is the reality in unsealed enclosures on a crusher floor or in a washdown area. The front of the contactor carries IP20 protection (finger-safe), while the terminals are IP00 — so the wiring zone needs to be inside a panel or enclosure. Side-by-side mounting is permitted with no derating gap, which saves rail space when stacking multiple contactors for a multi-motor group. ## Mechanical and electrical endurance — the so-what for maintenance planning Mechanical life is listed at 10 million operations typical, which means the contactor will outlast most of the equipment it switches before the coil or armature needs attention. The coil operates at 60 Hz with a voltage tolerance of 0.8 to 1.1 times rated value, so it holds in on a weak utility feed or a long cable run where voltage sag is a concern. ## Termination and wiring — what fits the screw terminals Main current circuit terminals are screw-type, accepting solid conductors 2x (0.25 to 2.5 mm²) and stranded conductors 2x (0.75 to 25 mm²) — the stranded range covers the full cross-section for a 41 A motor circuit. The terminal rating is IP00, so the wiring zone is not finger-safe; panel builders should cover or shield the terminals per local code. At 40 °C the minimum permissible conductor cross-section is 16 mm², which aligns with the AC-4 current draw — undersized wiring here would heat up under repeated plugging cycles. ## Lifecycle and compliance — current production with RoHS documentation Substance prohibition date is 05/01/2012, which aligns with the EU RoHS recast (RoHS 2) effective date — the contactor is compliant with the restricted substances list. Side-by-side mounting is permitted, and the unit carries the SIRIUS brand with standard Siemens documentation for CE, UL, and CSA compliance (nameplate markings, not a separate cert number in this listing).","metaTitle":"Siemens 3RT1036-3AV60 SIRIUS Power Contactor, Size S2, 55 mm","metaDescription":"Siemens 3RT1036-3AV60 SIRIUS power contactor, Size S2, 55 mm wide. AC-2 22 kW, AC-4 41 A at 400 V. Screw terminals, DIN rail snap-on. Current production. Sourced to order against R","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"115 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"55 mm","at AC":"7 ... 20 ms","Height":"112 mm","Stranded":"2x (0.75 ... 25 mm²)","at 60 Hz":"0.8 ... 1.1","Arcing Time":"10 ... 15 ms","On The Front":"IP20","1 Rated Value":"60 Hz","During Storage":"-55 ... +80 °C","Of The Terminal":"IP00","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"400 1/h","at AC-3 maximum":"800 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.75 ... 16 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 500 V rated value":"30 kW","at 60 Hz rated value":"480 V","at 690 V rated value":"11.4 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"22 kW","at AC-4 at 400 V rated value":"41 A","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"16 mm²","at 60 °C minimum permissible":"16 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"22 kW","at 690 V at 60 °C rated value":"66 kW","at AWG cables for main contacts":"2x (18 ... 2)","For Auxiliary And Control Circuit":"spring-loaded terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 80 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"fuse gL/gG: 160 A","at AWG cables for auxiliary contacts":"2x (24 ... 14)","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Thermal Short-Time Current Limited To 10 S":"400 A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","apparent holding power of magnet coil at AC":"12.6 VA","apparent pick-up power of magnet coil at AC":"166 VA","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.71","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.37","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"0","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=40910&mlfb=3RT1036-3AV60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1036-3AV60/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RT1036-3AV60 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is 3RT1036-3AV60's listed depth?","answer":"The depth is 115 mm, width is 55 mm, and height is 112 mm — the Size S2 frame fits standard 55 mm-wide DIN rail slots."},{"question":"What compliance documentation does 3RT1036-3AV60 carry?","answer":"The contactor has a substance prohibition date of 05/01/2012 (RoHS compliant) and is a SIRIUS brand product with standard CE, UL, and CSA markings per Siemens practice."},{"question":"Will 3RT1036-3AV60 drop into a panel specified around 3RT5036-1AP00 without rewiring?","answer":"Both are Size S2 contactors with screw-type terminals and 55 mm width, so the physical footprint and DIN rail mounting are the same. The main difference is the coil voltage and control circuit — verify the coil rating on your 3RT5036-1AP00 before swapping, as the 3RT1036-3AV60 has a 60 Hz coil with 0.8 to 1.1 tolerance."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1036-3AV60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1036-3AV60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}