{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1036-3BB40-ZN88X95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1036-3BB40-ZN88X95","canonicalUrl":"https://aoctrl.com/siemens/3RT1036-3BB40-ZN88X95","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1036-3BB40-ZN88X95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S2, 3RT1036-3BB40-ZN88X95, 24 VDC coil, screw-type terminals, 55 mm width, IP20 front, IP00 terminals.","salesMarkdown":"The Siemens SIRIUS 3RT1036-3BB40-ZN88X95 is a size S2 power contactor with a 24 VDC coil, rated for switching motor loads in industrial control panels. Rated for AC-3 duty at 400 V at 22 kW, this contactor handles typical three-phase induction motor starting and running without welding the main contacts. The AC-4 rating at 400 V at 41 A covers reversing or inching applications where the contacts break full-load current frequently. Mechanical life is 10,000,000 operations typical. The coil draws 10 A at 24 V rated value, with a dropout time of 20 to 25 ms at DC. ## Wiring and Integration Main circuit terminals are screw-type, accepting 2x solid wires from 0.25 to 2.5 mm² or 2x stranded from 0.75 to 25 mm². Operating temperature range is -25 to +60 °C, storage from -55 to +80 °C. The storage range is wider because the contactor isn't dissipating coil heat — handling, not running, is what that limit governs.","metaTitle":"Siemens SIRIUS 3RT1036-3BB40-ZN88X95 Power Contactor, S2, 24","metaDescription":"Siemens SIRIUS 3RT1036-3BB40-ZN88X95 power contactor, size S2, 24 VDC coil, screw terminals, 55 mm wide, IP20 front, current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"130 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"55 mm","at DC":"20 ... 25 ms","Height":"112 mm","Stranded":"2x (0.75 ... 25 mm²)","Arcing Time":"10 ... 15 ms","Rated Value":"24 V","On The Front":"IP20","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of The Terminal":"IP00","at AC-1 maximum":"1 000 1/h","at AC-2 maximum":"400 1/h","at AC-3 maximum":"800 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Full-Scale Value":"1.1","Size Of Contactor":"S2","Solid Or Stranded":"2x (0.75 ... 16 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 500 V rated value":"30 kW","at 690 V rated value":"11.4 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"22 kW","at AC-4 at 400 V rated value":"41 A","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"16 mm²","at 60 °C minimum permissible":"16 mm²","Insulation Voltage Rated Value":"690 V","at 230 V at 60 °C rated value":"22 kW","at 690 V at 60 °C rated value":"66 kW","at AWG cables for main contacts":"2x (18 ... 2)","For Auxiliary And Control Circuit":"spring-loaded terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 80 A","closing power of magnet coil at DC":"13.3 W","holding power of magnet coil at DC":"13.3 W","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"fuse gL/gG: 160 A","at AWG cables for auxiliary contacts":"2x (24 ... 14)","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Thermal Short-Time Current Limited To 10 S":"400 A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Type Of Voltage Of The Control Supply Voltage":"DC","Required Spacing For Grounded Parts At The Side":"6 mm","contact rating of auxiliary contacts according to UL":"A600 / Q600","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"0","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=426145&mlfb=3RT1036-3BB40-ZN88X95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1036-3BB40-ZN88X95/alternatives.json"},"ai":{"faq":[{"question":"What solid wire range does it accept?","answer":"The main circuit terminals accept 2x solid wires from 0.25 to 2.5 mm², and 2x stranded from 0.75 to 25 mm². The auxiliary terminals accept 2x solid or stranded from 0.75 to 16 mm²."},{"question":"Will it drop into a panel specified around 3RT1036-1AB00 without rewiring?","answer":"The physical footprint (S2 size, 55 mm width, 130 mm depth, DIN rail mount) is identical, so it fits the same panel cutout and rail. However, the coil voltage differs — 24 VDC on this variant versus whatever the 3RT1036-1AB00 carries — so the control wiring must match the new coil rating. Terminal types may also differ (screw vs. spring-cage), so check the termination before committing."},{"question":"What compliance documentation does this brand provide?","answer":"The part carries RoHS compliance with a substance prohibitance date of 05/01/2012, and is designed to meet IEC and UL standards typical for SIRIUS contactors. Specific certificates (UL, CSA, CE) are not listed in this record but are standard for the series."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1036-3BB40-ZN88X95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1036-3BB40-ZN88X95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}