{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1045-3AF08-0PA3-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1045-3AF08-0PA3-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RT1045-3AF08-0PA3-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1045-3AF08-0PA3-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S3, order code 3RT1045-3AF08-0PA3-ZX95, 37 kW AC-3 at 400 V, 66 A AC-4, screw terminals, DIN-rail mount.","salesMarkdown":"The Siemens 3RT1045-3AF08-0PA3-ZX95 is a SIRIUS S3 power contactor rated for 37 kW in AC-3 duty at 400 V and 66 A in AC-4 at 400 V — the AC-4 figure governs reversing or inching applications where the contactor breaks full motor current at each transition. Side-by-side mounting is permitted, so the contactor nests against adjacent SIRIUS devices without a mandatory air gap — useful when packing a multi-contactor motor starter group into a tight panel. Accepts 2x (0.25 to 2.5 mm²) solid or 2x (10 to 50 mm²) stranded — the stranded range covers the full motor feeder cross-section for a 37 kW load without needing an adapter lug. Dimensions: 146 mm high, 100 mm wide, 139 mm deep. The 139 mm depth includes the terminal projection; verify clearance to the gland plate or enclosure door in retrofit panels. ## Duty-cycle and thermal limits Rated for 50/60 Hz operation with a voltage tolerance of 0.8 to 1.1 times the nominal at 50 Hz. Maximum switching rates: 1 000 operations per hour in AC-3, 900 in AC-1, 400 in AC-2, and 300 in AC-4 — the AC-4 rate is the constraint for jogging or plugging cycles.","metaTitle":"Siemens 3RT1045-3AF08-0PA3-ZX95 SIRIUS Power Contactor, S3,","metaDescription":"Siemens SIRIUS 3RT1045-3AF08-0PA3-ZX95 S3 power contactor, 37 kW AC-3 at 400 V, 66 A AC-4. Screw terminals, DIN-rail mount. Current lifecycle stage. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"139 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"100 mm","at AC":"10 ... 25 ms","Height":"146 mm","Stranded":"2x (10 ... 50 mm²)","at 50 Hz":"0.8 ... 1.1","Arcing Time":"10 ... 15 ms","On The Front":"IP20; IP20 on the front with cover / box terminal","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","During Storage":"-55 ... +80 °C","Of The Terminal":"IP00","at AC-1 maximum":"900 1/h","at AC-2 maximum":"400 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"300 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm and 75 mm standard mounting rail","Size Of Contactor":"S3","Solid Or Stranded":"2x (2.5 ... 16 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"110 V","at 500 V rated value":"45 kW","at 690 V rated value":"21.1 kW","Side-By-Side Mounting":"Yes","at 1000 V rated value":"37 W","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"37 kW","at AC-4 at 400 V rated value":"66 A","at 40 °C minimum permissible":"50 mm²","at 60 °C minimum permissible":"35 mm²","Insulation Voltage Rated Value":"1 000 V","at 230 V at 60 °C rated value":"38 kW","at 690 V at 60 °C rated value":"114 kW","at 1000 V at 60 °C rated value":"82 W","at AWG cables for main contacts":"2x (10 ... 1/0)","For Auxiliary And Control Circuit":"spring-loaded terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 160 A","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"fuse gL/gG: 250 A","at AWG cables for auxiliary contacts":"2x (24 ... 14)","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Thermal Short-Time Current Limited To 10 S":"760 A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","apparent holding power of magnet coil at AC":"22 VA","apparent pick-up power of magnet coil at AC":"270 VA","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.68","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"3","number of NO contacts for auxiliary contacts instantaneous contact":"3","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=178387&mlfb=3RT1045-3AF08-0PA3-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1045-3AF08-0PA3-ZX95/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RT1045-3AF08-0PA3-ZX95 and get a price?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time."},{"question":"What is 3RT1045-3AF08-0PA3-ZX95's listed depth?","answer":"The depth is 139 mm, which includes the terminal projection. Check clearance to the enclosure door or gland plate in retrofit panels."},{"question":"What solid conductor range does this contactor accept?","answer":"The main terminals accept 2x (0.25 to 2.5 mm²) solid conductors. For stranded, the range is 2x (10 to 50 mm²), covering the full motor feeder for a 37 kW load."},{"question":"Will 3RT1045-3AF08-0PA3-ZX95 drop into a panel specified around 3RT1044-1FB46?","answer":"Both are SIRIUS S3 contactors with the same mounting footprint on 35/75 mm DIN rail. The terminal layout and screw-type terminals are identical, so no rewiring is needed for a direct swap. Verify the coil voltage and auxiliary block configuration match the existing circuit."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1045-3AF08-0PA3-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1045-3AF08-0PA3-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}