{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1046-1BG40","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1046-1BG40","canonicalUrl":"https://aoctrl.com/siemens/3RT1046-1BG40","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1046-1BG40","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S3, 3RT1046-1BG40, screw-type terminals, 45 kW AC-2 at 400 V, 55 kW at 500 V, snap-on mounting onto 35 mm and 75 mm rail.","salesMarkdown":"For AC-3 squirrel-cage motors, the power rating climbs to 55 kW at 500 V. The contactor also carries an AC-4 rating of 80 A at 400 V for plugging and inching applications that hammer the contacts harder. Side-by-side mounting is allowed. ## Terminal and environmental specs The contactor accepts solid conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), and max 2x (0.75 to 4 mm²). For stranded wire, it takes 2x (10 to 50 mm²). There's also a solid-or-stranded range of 2x (2.5 to 16 mm²). The enclosure rating is IP20 on the front with cover or box terminal, and IP00 at the terminal itself — so the panel builder needs to account for the open terminal area in the overall IP strategy. Dimensions are 146 mm height, 70 mm width, and 152 mm depth. The fastening method accepts both screw fixing and snap-on onto 35 mm and 75 mm standard mounting rail, which covers the two most common DIN rail profiles in industrial panels.","metaTitle":"Siemens 3RT1046-1BG40 SIRIUS Power Contactor, 45 kW AC-2 at","metaDescription":"Siemens 3RT1046-1BG40 SIRIUS power contactor, size S3. Rated 45 kW AC-2 at 400 V, 55 kW at 500 V. Screw terminals, snap-on 35/75 mm rail. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"152 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"70 mm","at DC":"14 ... 20 ms","Height":"146 mm","Stranded":"2x (10 ... 50 mm²)","Arcing Time":"10 ... 15 ms","Rated Value":"125 V","On The Front":"IP20; IP20 on the front with cover / box terminal","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of The Terminal":"IP00","at AC-1 maximum":"900 1/h","at AC-2 maximum":"350 1/h","at AC-3 maximum":"850 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm and 75 mm standard mounting rail","Full-Scale Value":"1.1","Size Of Contactor":"S3","Solid Or Stranded":"2x (2.5 ... 16 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 500 V rated value":"55 kW","at 690 V rated value":"25.4 kW","Side-By-Side Mounting":"Yes","at 1000 V rated value":"37 W","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"45 kW","at AC-4 at 400 V rated value":"80 A","Substance Prohibitance (Date)":"05/01/2012","at 40 °C minimum permissible":"50 mm²","at 60 °C minimum permissible":"35 mm²","Insulation Voltage Rated Value":"1 000 V","at 230 V at 60 °C rated value":"38 kW","at 690 V at 60 °C rated value":"114 kW","at 1000 V at 60 °C rated value":"98 W","at AWG cables for main contacts":"2x (10 ... 1/0)","For Auxiliary And Control Circuit":"screw-type terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 160 A","closing power of magnet coil at DC":"15 W","holding power of magnet coil at DC":"15 W","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"fuse gL/gG: 250 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Thermal Short-Time Current Limited To 10 S":"760 A","Finely Stranded Without Core End Processing":"2x (10 ... 35 mm²)","Type Of Voltage Of The Control Supply Voltage":"DC","Required Spacing For Grounded Parts At The Side":"6 mm","contact rating of auxiliary contacts according to UL":"A600 / Q600","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"0","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=179621&mlfb=3RT1046-1BG40","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1046-1BG40/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1046-1BG40","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1046-1BG40 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}