{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1054-1PP35","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1054-1PP35","canonicalUrl":"https://aoctrl.com/siemens/3RT1054-1PP35","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1054-1PP35","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S6, 3RT1054-1PP35, 200-277 VAC coil, screw-type terminals, 172 x 140 x 170 mm.","salesMarkdown":"## SIRIUS power contactor, size S6 — 3RT1054-1PP35 The coil is rated for 200-277 VAC, and the contactor accepts stranded power cables from 16 to 70 mm² — that covers most motor feeds up to about 55 kW at 400 V, depending on duty. That same rate applies under AC-3e (enhanced) as well. Under AC-4 (plugging/inching) the rate drops to 130 ops/h, so if your application involves frequent reversing or jogging, you'll need to account for that lower duty. The mechanical life is typical for the class at 10 million operations. Mounting is screw-fix to a vertical surface; the contactor can be rotated ±90° or tilted ±22.5° front-to-back, which gives flexibility in tight enclosures. Clearances: 10 mm upwards, downwards, and to the side; 20 mm forwards — that's the arcing zone, so don't crowd it against sheet metal or other devices. Coil pickup and dropout timing is 80-90 ms on both AC and DC supplies, with arcing time 10-15 ms. The coil hold-in power factor is 0.6 at both 50 and 60 Hz. The rated value of 200-277 VAC covers most European and North American control voltages in that band.","metaTitle":"Siemens 3RT1054-1PP35 SIRIUS Power Contactor, Size S6, 200-2","metaDescription":"Siemens 3RT1054-1PP35 SIRIUS power contactor, size S6, 200-277 VAC coil, rated for AC-3 switching at 1000 ops/h. Active lifecycle, sourced to order. Dimensions 172x140x170 mm.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"170 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"140 mm","at AC":"80 ... 90 ms","at DC":"80 ... 90 ms","title":"3RT1054-1PP35","Height":"172 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"16 ... 70 mm²","at 50 Hz":"0.6","at 60 Hz":"0.6","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"200 ... 277 V","description":"power contactor, AC-3e/AC-3 115 A, 55 kW / 400 V, AC (50-60 Hz) / DC Uc: 200-277 V PLC input 24 V DC 3-pole, auxiliary contacts 1 NO + 1 NC drive: electronic main circuit: box terminal control and auxiliary circuit: screw terminal, remaining lifetime signal","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-1 maximum":"800 1/h","at AC-2 maximum":"400 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"130 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","at AC-3e maximum":"1 000 1/h","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S6","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"25 hp","at 400 V rated value":"3 A","at 440 V rated value":"1.4 A","at 480 V rated value":"124 A","at 50 Hz rated value":"200 ... 277 V","at 500 V rated value":"2 A","at 60 Hz rated value":"200 ... 277 V","at 600 V rated value":"125 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"75 kW","For Auxiliary Contacts":"18 ... 14","For Main Current Circuit":"box terminal","at 200/208 V rated value":"40 hp","at 220/230 V rated value":"50 hp","at 460/480 V rated value":"100 hp","at 575/600 V rated value":"125 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","at AC-3 rated value maximum":"1 000 V","at AC in hot operating state":"21 W","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"97 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"05/01/2012","Design Of The Surge Suppressor":"with varistor","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"140 A","at AC-5b up to 400 V rated value":"95 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 250 A (690 V, 100 kA), aM: 200 A (690 V, 50 kA), BS88: 250 A (415 V, 50 kA)","Without Load Current Share Typical":"2.8 W","closing power of magnet coil at DC":"320 W","holding power of magnet coil at DC":"2.8 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 355 A (690 V, 100 kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"7 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","voltage at PLC-control input rated value":"24 V","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","Finely Stranded Without Core End Processing":"16 ... 70 mm²","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Limited To 1 S Switching At Zero Current Maximum":"2 565 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"1 654 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"1 170 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"729 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"572 A; Use minimum cross-section acc. to AC-1 rated value","type of PLC-control input according to IEC 60947-1":"Type 2","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","operating range factor of the voltage at PLC-control input":"0.8 ... 1.1","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","for short-circuit protection of the RLT relay output required":"miniature fuse: 4 A FF (230 V, Ik= 400 A)","minimum cross-section in main circuit at maximum AC-1 rated value":"70 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/48191814343ef1de12d436857500061f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=389070&mlfb=3RT1054-1PP35"},"ai":{"faq":[{"question":"What is the switching rate for motor duty on 3RT1054-1PP35?","answer":"Under AC-3 (motor starting) and AC-3e duty, the maximum switching rate is 1,000 operations per hour. Under AC-4 (plugging/reversing) it drops to 130 ops/h."},{"question":"What wire sizes does the main power terminal accept?","answer":"The main power terminals accept stranded copper from 16 mm² up to 70 mm². The auxiliary switch terminals accept 0.5 to 4 mm² solid or stranded."},{"question":"Where can I buy 3RT1054-1PP35?","answer":"This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1054-1PP35","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1054-1PP35 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}