{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1054-2AM36","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1054-2AM36","canonicalUrl":"https://aoctrl.com/siemens/3RT1054-2AM36","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1054-2AM36","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, Size S6 power contactor, order code 3RT1054-2AM36, 200-220 V AC coil, spring-type terminals, 172 x 120 x 170 mm.","salesMarkdown":"The S6 frame covers motor loads up to the current limit defined by the utilization category. Main power terminals accept stranded cable up to 120 mm², which is generous for the frame size and covers most motor feeder requirements without a separate terminal block. That covers most panel layouts, including top-entry cable trays where the contactor sits rotated 90° from the standard orientation. ## Duty-cycle capacity — what the switching-frequency ratings mean This contactor is rated for 1,000 cycles per hour in AC-3 and AC-3e duty. For AC-1 resistive loads it is 800 cycles/hour, and for AC-4 it drops to 130 cycles/hour. That's typical for a contactor this size — fast enough for most motor starting but not for precision switching of resistive loads where zero-crossing matters. The auxiliary switch is included — it's not a separate add-on module. That saves a catalog number and a DIN slot if you need one N/O + one N/C for feedback or interlocking. Auxiliary contact ratings are 10 A at 24 V, 2 A at 48 V, 2 A at 60 V, and 1 A at 110 V — adequate for PLC inputs and relay coils in the same panel. ## Panel integration — dimensions and clearances The envelope is 172 mm high, 120 mm wide, 170 mm deep. That's a Size S6 footprint — it needs a backplate area roughly 172 x 120 mm, plus clearance for cable bending and arc flash. The forward clearance of 20 mm is the one that catches people — if you're mounting a gland plate or a cover closer than that, you're outside the spec. Fastening is via screw fixing through a single 9 mm diameter hole. That's a single-point mount — not a four-corner bolt pattern — so the backplate needs to be rigid enough to prevent the contactor from twisting under cable pull.","metaTitle":"Siemens SIRIUS 3RT1054-2AM36 Power Contactor, Size S6, 200-2","metaDescription":"Siemens SIRIUS 3RT1054-2AM36 Size S6 power contactor, 200-220V AC coil, spring-type terminals. Rated for AC-3 switching up to 1000 cycles/hour. Current lifecycle stage; sourced to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"170 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"120 mm","at AC":"40 ... 60 ms","at DC":"40 ... 60 ms","Height":"172 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"25 ... 120 mm²","at 50 Hz":"0.8","at 60 Hz":"0.8","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"200 ... 220 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","Number Of Holes":"1","at AC-1 maximum":"800 1/h","at AC-2 maximum":"400 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"130 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","at AC-3e maximum":"1 000 1/h","Diameter Of Holes":"9 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S6","Solid Or Stranded":"2x (0,25 ... 2,5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"25 hp","at 400 V rated value":"3 A","at 440 V rated value":"1.4 A","at 480 V rated value":"124 A","at 50 Hz rated value":"200 ... 220 V","at 500 V rated value":"2 A","at 60 Hz rated value":"200 ... 220 V","at 600 V rated value":"125 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"75 kW","For Auxiliary Contacts":"24 ... 14","Width Of Connection Bar":"17 mm","For Main Current Circuit":"Connection bar","at 200/208 V rated value":"40 hp","at 220/230 V rated value":"50 hp","at 460/480 V rated value":"100 hp","at 575/600 V rated value":"125 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Thickness Of Connection Bar":"3 mm","at AC-3 rated value maximum":"1 000 V","at AC in hot operating state":"21 W","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"97 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"05/01/2012","Design Of The Surge Suppressor":"with varistor","at AWG cables for main contacts":"4 ... 250 kcmil","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"140 A","at AC-5b up to 400 V rated value":"95 A","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 250 A (690 V, 100 kA), aM: 200 A (690 V, 50 kA), BS88: 250 A (415 V, 50 kA)","Without Load Current Share Typical":"5.2 W","closing power of magnet coil at DC":"360 W","holding power of magnet coil at DC":"5.2 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","With Type Of Coordination 1 Required":"gG: 355 A (690 V, 100 kA)","at AWG cables for auxiliary contacts":"2x (24 ... 14)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"7 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Limited To 1 S Switching At Zero Current Maximum":"2 565 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"1 654 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"1 170 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"729 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"572 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"70 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/48191814343ef1de12d436857500061f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=312894&mlfb=3RT1054-2AM36","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1054-2AM36/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional alternative to 3RT1054-2AM36?","answer":"The peer 3RT1055-6QF35 is a Size S6 contactor in the same SIRIUS family, but it uses a different coil voltage and terminal configuration. The 3RT1054-2AM36 has a 200-220 V AC coil with spring-type terminals; the 3RT1055-6QF35 uses a different coil and screw-type terminals. They share the same frame size and mounting footprint, so they can physically swap, but the coil voltage and termination method differ — verify your control voltage and wiring preference before substituting."},{"question":"What are the key dimensions of 3RT1054-2AM36?","answer":"Height 172 mm, width 120 mm, depth 170 mm. Minimum clearances: 10 mm upwards, 10 mm downwards, 10 mm sides, 20 mm forwards."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1054-2AM36","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1054-2AM36 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}