{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1054-6NF36","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1054-6NF36","canonicalUrl":"https://aoctrl.com/siemens/3RT1054-6NF36","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1054-6NF36","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S6, order code 3RT1054-6NF36, 96-127 VAC coil, screw-type terminals, 170 mm depth, auxiliary switch included.","salesMarkdown":"## SIRIUS S6 power contactor, 96-127 VAC coil The coil is rated for 96-127 VAC, with a pick-up threshold of 0.8 x rated value. Operating time is 80-90 ms on both AC and DC, and arcing time is 10-15 ms. ## Switching frequency and duty ratings Maximum switching rates vary by duty: 800 cycles/hour under AC-1 (resistive), 400 under AC-2 (slip-ring motors), 1000 under AC-3 (squirrel-cage motors), and 130 under AC-4 (plugging/inching) (-). AC-3e matches AC-3 at 1000 cycles/hour. Mounting is screw fixing with four 9 mm holes. The contactor can be mounted on a vertical surface, rotatable ±90° and tiltable ±22.5°. Clearance requirements: 10 mm upwards/downwards/side, 20 mm forwards. Main power terminals accept stranded wire 25-120 mm². Auxiliary/coil terminals accept solid or stranded 0.5-1.5 mm² (2x) or 0.75-2.5 mm² (2x), max 4 mm². Dimensions: 172 mm high, 120 mm wide, 170 mm deep. ## Sourcing and fit note For a panel originally specified around the 3RT1054-2AP36 (a sibling with a different coil voltage), the mechanical footprint and wiring scheme are identical — both are size S6 with screw fixing and the same clearance requirements — so no rewiring is needed for the mounting base; only the coil supply must match the 96-127 VAC rating of this variant.","metaTitle":"Siemens 3RT1054-6NF36 SIRIUS Power Contactor, S6, 96-127 VAC","metaDescription":"Siemens 3RT1054-6NF36 SIRIUS power contactor, size S6, 96-127 VAC coil, 170 mm depth. Screw fixing, aux switch included. Current production. Request RFQ for pricing and availabilit","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"170 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"120 mm","at AC":"80 ... 90 ms","at DC":"80 ... 90 ms","Height":"172 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"25 ... 120 mm²","at 50 Hz":"0.6","at 60 Hz":"0.6","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"96 ... 127 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Number Of Holes":"1","at AC-1 maximum":"800 1/h","at AC-2 maximum":"400 1/h","at AC-3 maximum":"1 000 1/h","at AC-4 maximum":"130 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","at AC-3e maximum":"1 000 1/h","Diameter Of Holes":"9 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S6","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"25 hp","at 400 V rated value":"3 A","at 440 V rated value":"1.4 A","at 480 V rated value":"124 A","at 50 Hz rated value":"96 ... 127 V","at 500 V rated value":"2 A","at 60 Hz rated value":"96 ... 127 V","at 600 V rated value":"125 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"75 kW","For Auxiliary Contacts":"18 ... 14","Width Of Connection Bar":"17 mm","For Main Current Circuit":"Connection bar","at 200/208 V rated value":"40 hp","at 220/230 V rated value":"50 hp","at 460/480 V rated value":"100 hp","at 575/600 V rated value":"125 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Thickness Of Connection Bar":"3 mm","at AC-3 rated value maximum":"1 000 V","at AC in hot operating state":"21 W","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"97 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"05/01/2012","Design Of The Surge Suppressor":"with varistor","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"140 A","at AC-5b up to 400 V rated value":"95 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 250 A (690 V, 100 kA), aM: 200 A (690 V, 50 kA), BS88: 250 A (415 V, 50 kA)","Without Load Current Share Typical":"2.8 W","closing power of magnet coil at DC":"320 W","holding power of magnet coil at DC":"2.8 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 355 A (690 V, 100 kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"7 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","voltage at PLC-control input rated value":"24 V","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Limited To 1 S Switching At Zero Current Maximum":"2 565 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"1 654 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"1 170 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"729 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"572 A; Use minimum cross-section acc. to AC-1 rated value","type of PLC-control input according to IEC 60947-1":"Type 2","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","operating range factor of the voltage at PLC-control input":"0.8 ... 1.1","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"70 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/48191814343ef1de12d436857500061f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=384264&mlfb=3RT1054-6NF36","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1054-6NF36/alternatives.json"},"ai":{"faq":[{"question":"What is the coil voltage for 3RT1054-6NF36?","answer":"The coil is rated for 96-127 VAC, with a pick-up threshold of 0.8 times the rated value."},{"question":"What are the mounting dimensions and clearances for 3RT1054-6NF36?","answer":"Dimensions are 172 mm high, 120 mm wide, 170 mm deep. Mounting requires 10 mm clearance upwards, downwards, and to the sides, and 20 mm forwards."},{"question":"How do I get current pricing and availability for 3RT1054-6NF36?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit an RFQ to confirm current pricing and availability at quote time."},{"question":"Will 3RT1054-6NF36 drop into a panel specified for 3RT1054-2AP36?","answer":"Yes, both are size S6 contactors with screw fixing and identical mechanical footprint and clearance requirements, so no rewiring of the mounting base is needed. Only the coil supply must match the 96-127 VAC rating of this variant."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1054-6NF36","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1054-6NF36 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}