{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1055-2AV36","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1055-2AV36","canonicalUrl":"https://aoctrl.com/siemens/3RT1055-2AV36","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1055-2AV36","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, 3RT1055-2AV36, Size S6, 380-420 V AC coil, spring-type terminals, screw fixing.","salesMarkdown":"The coil is wound for 380-420 V AC, and the main power terminals accept stranded cable from 25 to 120 mm² — sized for the higher-current branch circuits this frame serves. Mounts via screw fixing (9 mm holes) on a vertical surface, rotatable ±90° or tiltable ±22.5° front-to-back. The body measures 172 mm high, 120 mm wide, 170 mm deep — plan the enclosure depth around that 170 mm figure, plus the 20 mm forward clearance for arc venting and the 10 mm side/downward clearances. Coil connections use spring-type terminals (2x 0.25-2.5 mm² solid or stranded), so no screwdriver needed on the control wiring. ## Switching Performance & Duty Arcing time runs 10-15 ms. The contactor handles up to 800 operations per hour in AC-1 (resistive) duty, 750/h in AC-3 (motor start/run), and 130/h in AC-4 (plugging/inching). The auxiliary switch is built in, rated at 10 A at 24 V, 2 A at 48/60 V, and 1 A at 110 V — enough for pilot-duty signaling. ## Environmental & Lifecycle The lifecycle status is listed as current — this is an active catalog item, not a phase-out.","metaTitle":"Siemens 3RT1055-2AV36 SIRIUS Power Contactor, Size S6, 380-4","metaDescription":"Siemens 3RT1055-2AV36 SIRIUS power contactor, Size S6, 380-420 V AC coil, spring-type terminals. Rated for motor and resistive loads. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"170 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"120 mm","at AC":"40 ... 60 ms","at DC":"40 ... 60 ms","title":"3RT1055-2AV36","Height":"172 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"25 ... 120 mm²","at 50 Hz":"0.8","at 60 Hz":"0.8","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"380 ... 420 V","description":"power contactor, AC-3e/AC-3 150 A, 75 kW / 400 V AC (50-60 Hz) / DC Uc: 380-420 V 3-pole, auxiliary contacts 2 NO + 2 NC drive: conventional main circuit: busbar control and auxiliary circuit: spring-loaded terminal","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","Number Of Holes":"1","at AC-1 maximum":"800 1/h","at AC-2 maximum":"300 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"130 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","at AC-3e maximum":"750 1/h","Diameter Of Holes":"9 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S6","Solid Or Stranded":"2x (0,25 ... 2,5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"30 hp","at 400 V rated value":"3 A","at 440 V rated value":"1.4 A","at 480 V rated value":"156 A","at 50 Hz rated value":"380 ... 420 V","at 500 V rated value":"2 A","at 60 Hz rated value":"380 ... 420 V","at 600 V rated value":"144 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"90 kW","For Auxiliary Contacts":"24 ... 14","Width Of Connection Bar":"17 mm","For Main Current Circuit":"Connection bar","at 200/208 V rated value":"50 hp","at 220/230 V rated value":"60 hp","at 460/480 V rated value":"125 hp","at 575/600 V rated value":"150 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Thickness Of Connection Bar":"3 mm","at AC-3 rated value maximum":"1 000 V","at AC in hot operating state":"27 W","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"132 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"05/01/2012","Design Of The Surge Suppressor":"with varistor","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"162 A","at AC-5b up to 400 V rated value":"124 A","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 315 A (690 V, 100 kA), aM: 200 A (690 V, 50 kA), BS88: 315 A (415 V, 50 kA)","Without Load Current Share Typical":"5.2 W","closing power of magnet coil at DC":"360 W","holding power of magnet coil at DC":"5.2 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","With Type Of Coordination 1 Required":"gG: 355 A (690 V, 100 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"9 W","for AWG cables for auxiliary contacts":"2x (24 ... 14)","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Limited To 1 S Switching At Zero Current Maximum":"2 727 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"1 831 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"1 300 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"850 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"703 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"95 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/48191814343ef1de12d436857500061f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=284050&mlfb=3RT1055-2AV36"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RT1055-2AV36?","answer":"Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time."},{"question":"What is 3RT1055-2AV36's listed depth?","answer":"The depth is 170 mm."},{"question":"What is 3RT1055-2AV36's listed solid wire capacity?","answer":"The auxiliary/coil terminals accept 2x solid conductors from 0.25 to 2.5 mm²."},{"question":"Will 3RT1055-2AV36 drop into a panel specified around 3RT1055-6QF35 without rewiring?","answer":"Both are Size S6 contactors with the same mounting footprint and screw-fixing pattern, so the mechanical swap is straightforward. The coil voltage differs — this unit is 380-420 V AC versus the 6QF35's coil — so verify the control circuit voltage before installing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1055-2AV36","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1055-2AV36 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}