{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1056-6AB36-3PA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1056-6AB36-3PA0","canonicalUrl":"https://aoctrl.com/siemens/3RT1056-6AB36-3PA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1056-6AB36-3PA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S6, order 3RT1056-6AB36-3PA0, 23-26 V DC coil, integrated auxiliary switch.","salesMarkdown":"Siemens 3RT1056-6AB36-3PA0 is a SIRIUS size S6 power contactor with a built-in auxiliary switch. Coil rated for 23-26 V DC, switching frequency up to 750 operations per hour in AC-3 duty. Main power terminals accept stranded conductors from 25 to 120 mm²; auxiliary terminals handle solid or stranded wire up to 4 mm². Screw fixing, mounting surface can be rotated ±90°, tilted ±22.5°. ## Mounting & Dimensions Size S6: 172 mm high, 120 mm wide, 170 mm deep. Screw fixing with four 9 mm holes on a standard mounting plate.","metaTitle":"Siemens 3RT1056-6AB36-3PA0 SIRIUS S6 Contactor, 23-26V Coil","metaDescription":"SIRIUS size S6 power contactor, active production, with integral auxiliary switch. Coil 23-26 V DC. Dimensions 172x120x170 mm. RFQ for best lead time.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"170 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"120 mm","at AC":"40 ... 60 ms","at DC":"40 ... 60 ms","Height":"172 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"25 ... 120 mm²","at 50 Hz":"0.8","at 60 Hz":"0.8","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"23 ... 26 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Number Of Holes":"1","at AC-1 maximum":"800 1/h","at AC-2 maximum":"300 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"130 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","at AC-3e maximum":"750 1/h","Diameter Of Holes":"9 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S6","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"30 hp","at 400 V rated value":"3 A","at 440 V rated value":"1.4 A","at 480 V rated value":"180 A","at 50 Hz rated value":"23 ... 26 V","at 500 V rated value":"2 A","at 60 Hz rated value":"23 ... 26 V","at 600 V rated value":"192 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"90 kW","For Auxiliary Contacts":"18 ... 14","Width Of Connection Bar":"17 mm","For Main Current Circuit":"Connection bar","at 200/208 V rated value":"60 hp","at 220/230 V rated value":"75 hp","at 460/480 V rated value":"150 hp","at 575/600 V rated value":"200 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Thickness Of Connection Bar":"3 mm","at AC-3 rated value maximum":"1 000 V","at AC in hot operating state":"39 W","at AC-2 at 400 V rated value":"90 kW","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"160 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"05/01/2012","Design Of The Surge Suppressor":"with varistor","at AWG cables for main contacts":"4 ... 250 kcmil","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"189 A","at AC-5b up to 400 V rated value":"153 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 315 A (690 V, 100 kA), aM: 200 A (690 V, 50 kA), BS88: 315 A (415 V, 50 kA)","Without Load Current Share Typical":"5.2 W","closing power of magnet coil at DC":"360 W","holding power of magnet coil at DC":"5.2 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 355 A (690 V, 100 kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"13 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Limited To 1 S Switching At Zero Current Maximum":"2 900 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"2 084 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"1 480 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"968 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"801 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"95 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/48191814343ef1de12d436857500061f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=184864&mlfb=3RT1056-6AB36-3PA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1056-6AB36-3PA0/alternatives.json"},"ai":{"faq":[{"question":"What's the closest functional cross-reference — 3RT1056-6AB36?","answer":"3RT1056-6AB36 is the base version without the auxiliary switch. This -3PA0 variant includes the auxiliary switch but shares the same S6 frame and mounting, so it fits the same panel envelope."},{"question":"What is the listed depth of 3RT1056-6AB36-3PA0?","answer":"170 mm."},{"question":"What solid conductor sizes does the auxiliary terminal accept?","answer":"Solid conductors: 2x (0.5...1.5 mm²), 2x (0.75...2.5 mm²), max. 2x (0.75...4 mm²)."},{"question":"Will it drop into a panel specified around 3RT1056-6AB36 without rewiring?","answer":"Yes, the frame size and terminal layout are identical, so the physical swap is straightforward. The only difference is the auxiliary switch is integrated on this variant, so if the base panel did not have an auxiliary block, you now have one that may need to be wired or left unused."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1056-6AB36-3PA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1056-6AB36-3PA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}