{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1064-2AV36","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1064-2AV36","canonicalUrl":"https://aoctrl.com/siemens/3RT1064-2AV36","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1064-2AV36","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S10, 3RT1064-2AV36, 380-420 V AC coil, spring-type terminals, screw fixing, 210 x 145 x 202 mm.","salesMarkdown":"The S10 frame size measures 210 mm high, 145 mm wide, and 202 mm deep — a substantial footprint that needs a backplate or sub-panel with enough real estate. These aren't suggestions; they're the minimum air gaps to maintain arc flash and heat dissipation paths. Skimp on them and you risk tracking or nuisance tripping in a crowded enclosure. The main power circuit accepts stranded conductors from 70 up to 240 mm² — that's a heavy cable range, typical for motor feeders in the 50-100 A class. Spring-type terminals on the coil mean no screw torque to check; strip and push. ## Duty-cycle performance Switching frequency varies by duty class: 750 cycles/hour in AC-1 (resistive loads), 500 in AC-3 (standard motor starting), 250 in AC-2 (slip-ring motors), and 130 in AC-4 (plugging/inching). The AC-3e rating also sits at 500 cycles/hour. For a conveyor drive running continuous start/stop cycles, that 500 c/h ceiling is the real limiter — not the thermal current. Arcing time runs 10... 15 ms. The auxiliary contact ratings are 10 A at 24 V, 2 A at 48 V, 2 A at 60 V, and 1 A at 110 V — these matter for your PLC input or relay interlock circuits. No phase-out or last-time-buy notice is attached to this variant.","metaTitle":"Siemens 3RT1064-2AV36 SIRIUS Power Contactor, Size S10, 380-","metaDescription":"Siemens 3RT1064-2AV36 SIRIUS power contactor, size S10. 380-420 V AC coil, spring-type terminals, screw fixing. Rated for AC-3 switching at 500 cycles/h. Current lifecycle stage. S","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"202 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"145 mm","at AC":"40 ... 80 ms","at DC":"40 ... 80 ms","title":"3RT1064-2AV36","Height":"210 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"70 ... 240 mm²","at 50 Hz":"0.9","at 60 Hz":"0.9","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"380 ... 420 V","description":"power contactor, AC-3e/AC-3 225 A, 110 kW / 400 V AC (50-60 Hz) / DC Uc: 380-420 V 3-pole, auxiliary contacts 2 NO + 2 NC drive: conventional main circuit: busbar control and auxiliary circuit: spring-loaded terminal","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","Number Of Holes":"1","at AC-1 maximum":"750 1/h","at AC-2 maximum":"250 1/h","at AC-3 maximum":"500 1/h","at AC-4 maximum":"130 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","at AC-3e maximum":"500 1/h","Diameter Of Holes":"11 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S10","Solid Or Stranded":"2x (0,25 ... 2,5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 440 V rated value":"1.4 A","at 480 V rated value":"180 A","at 50 Hz rated value":"380 ... 420 V","at 500 V rated value":"2 A","at 60 Hz rated value":"380 ... 420 V","at 600 V rated value":"192 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"90 kW","For Auxiliary Contacts":"24 ... 14","Width Of Connection Bar":"25 mm","For Main Current Circuit":"Connection bar","at 200/208 V rated value":"60 hp","at 220/230 V rated value":"75 hp","at 460/480 V rated value":"150 hp","at 575/600 V rated value":"200 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Thickness Of Connection Bar":"6 mm","at AC-3 rated value maximum":"1 000 V","at AC in hot operating state":"51 W","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"195 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"05/01/2012","Design Of The Surge Suppressor":"with varistor","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"242 A","at AC-5b up to 400 V rated value":"186 A","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 400 A (690 V, 100 kA), aM: 315 A (690 V, 50 kA), BS88: 400 A (415 V, 50 kA)","Without Load Current Share Typical":"7.4 W","closing power of magnet coil at DC":"650 W","holding power of magnet coil at DC":"7.4 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","With Type Of Coordination 1 Required":"gG: 500 A (690 V, 100 kA)","at AWG cables for auxiliary contacts":"2x (24 ... 14)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"17 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Limited To 1 S Switching At Zero Current Maximum":"4 000 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"2 807 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"2 082 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"1 397 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"1 144 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"150 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/43c1fdc68a718c0f6563b26eb28a2bc8.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=389387&mlfb=3RT1064-2AV36"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RT1064-2AV36?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at the time of quote — submit an RFQ for a firm price and lead time."},{"question":"What are the physical dimensions of 3RT1064-2AV36?","answer":"The contactor measures 210 mm high, 145 mm wide, and 202 mm deep. Minimum clearance distances are 10 mm upwards, 10 mm downwards, 20 mm forwards, and 10 mm at the side."},{"question":"What conductor sizes does 3RT1064-2AV36 accept?","answer":"The main power circuit accepts stranded conductors from 70 to 240 mm². The auxiliary and coil terminals accept solid or stranded wire from 0.25 to 2.5 mm², using spring-type terminals on the coil."},{"question":"What compliance documentation does this brand provide for 3RT1064-2AV36?","answer":"As a Siemens SIRIUS product, this contactor is manufactured to IEC/EN 60947-4-1 standards. Specific compliance declarations (RoHS, REACH, UL, IEC) are available from Siemens upon request or through their documentation portal. The evidence does not list specific certification marks on this variant."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1064-2AV36","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1064-2AV36 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}