{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1064-6AF36-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1064-6AF36-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RT1064-6AF36-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1064-6AF36-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S10, order code 3RT1064-6AF36-ZX95, 110-127 V AC coil, screw-type terminals, 202 mm depth.","salesMarkdown":"Its 110-127 V AC coil pulls in reliably down to 0.8 × rated voltage and drops out cleanly; the magnet coil uses screw-type terminals for secure wiring. The contactor carries an auxiliary switch block for feedback or interlock circuits, with DC switching ratings that matter for PLC inputs — 10 A at 24 V, 2 A at 48 V, 2 A at 60 V, 1 A at 110 V, and 0.9 A at 125 V. Mounts via screw fixing with a single 11 mm hole. Dimensions are 210 mm high, 145 mm wide, and 202 mm deep — the depth is the key clearance number for gland-plate planning. Main power terminals accept stranded wire from 70 to 240 mm²; auxiliary terminals handle 2× (0.5 to 1.5 mm²) solid, 2× (0.75 to 2.5 mm²) stranded, or max 2× (0.75 to 4 mm²). Switching frequency varies by duty class: up to 750 operations per hour at AC-1 (resistive), 250/h at AC-2 (slip-ring motors), 500/h at AC-3 (squirrel-cage motors), and 130/h at AC-4 (plugging/inching). The full-scale overload factor is 1.1, meaning the contactor can handle 10% above its rated continuous current for short durations — useful when sizing for motor inrush.","metaTitle":"Siemens 3RT1064-6AF36-ZX95 SIRIUS Power Contactor, S10, 110-","metaDescription":"Siemens SIRIUS 3RT1064-6AF36-ZX95 power contactor, size S10, 110-127 V AC coil, screw terminals, 202 mm depth. Currently active. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"202 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"145 mm","at AC":"40 ... 80 ms","at DC":"40 ... 80 ms","Height":"210 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"70 ... 240 mm²","at 50 Hz":"0.9","at 60 Hz":"0.9","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"110 ... 127 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Number Of Holes":"1","at AC-1 maximum":"750 1/h","at AC-2 maximum":"250 1/h","at AC-3 maximum":"500 1/h","at AC-4 maximum":"130 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","Diameter Of Holes":"11 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S10","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 440 V rated value":"1.4 A","at 480 V rated value":"180 A","at 50 Hz rated value":"110 ... 127 V","at 500 V rated value":"2 A","at 60 Hz rated value":"110 ... 127 V","at 600 V rated value":"192 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"90 kW","For Auxiliary Contacts":"18 ... 14","Width Of Connection Bar":"25 mm","For Main Current Circuit":"Connection bar","at 200/208 V rated value":"60 hp","at 220/230 V rated value":"75 hp","at 460/480 V rated value":"150 hp","at 575/600 V rated value":"200 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Thickness Of Connection Bar":"6 mm","at AC-3 rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"195 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"05/01/2012","Design Of The Surge Suppressor":"with varistor","at AWG cables for main contacts":"2/0 ... 500 kcmil","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"242 A","at AC-5b up to 400 V rated value":"186 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 400 A (690 V, 100 kA), aM: 315 A (690 V, 50 kA), BS88: 400 A (415 V, 50 kA)","closing power of magnet coil at DC":"650 W","holding power of magnet coil at DC":"7.4 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 500 A (690 V, 100 kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Limited To 1 S Switching At Zero Current Maximum":"4 000 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"2 807 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"2 082 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"1 397 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"1 144 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"150 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=152915&mlfb=3RT1064-6AF36-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1064-6AF36-ZX95/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of 3RT1064-6AF36-ZX95?","answer":"The depth is 202 mm. This is the dimension from the mounting surface to the furthest protruding point."},{"question":"What wire sizes do the auxiliary terminals accept?","answer":"The auxiliary terminals accept 2× (0.5 to 1.5 mm²) solid, 2× (0.75 to 2.5 mm²) stranded, or a maximum of 2× (0.75 to 4 mm²)."},{"question":"Will 3RT1064-6AF36-ZX95 drop into a panel specified around 3RT1056-6AF36-0UA0 without rewiring?","answer":"Not without checking dimensions and terminal clearances. The 3RT1064 is an S10 frame, which is physically larger than the 3RT1056 frame. The main power terminals accept 70-240 mm² stranded, which may be larger than what the panel was wired for. The mounting hole pattern (single 11 mm hole,) and clearance distances (10 mm side, 20 mm forward, ///) should be verified against the existing panel layout."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1064-6AF36-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1064-6AF36-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}