{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1064-6AM36","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1064-6AM36","canonicalUrl":"https://aoctrl.com/siemens/3RT1064-6AM36","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1064-6AM36","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, S10 size, 200-220 V AC coil, screw-type terminals, 202 mm depth, 145 mm width, 210 mm height.","salesMarkdown":"The AC-3 switching frequency of 500 operations per hour tells you this contactor is rated for continuous motor starting duty — think conveyors, pumps, compressors running multiple start-stop cycles per shift. The AC-4 rating drops to 130 ops/h, which covers inching and plugging duty where the contacts break full-load current on every transition. If your application is strictly resistive heating or lighting, the AC-1 rating of 750 ops/h gives you headroom for frequent cycling. In real AC-3 motor service, you'll get a fraction of that before the contacts need inspection, but the mechanical figure tells you the actuator won't seize up before the electrical life is exhausted. The auxiliary contact block is built in (not a bolt-on), rated at 10 A at 24 V, 2 A at 48-60 V, and 1 A at 110 V. ## Mounting and wiring constraints for the panel builder This contactor mounts via screw fixing with an 11 mm hole diameter — not a snap-on DIN rail mount. That means you need a backplate or mounting rail with pre-drilled holes, and you'll need M10 or 3/8\" bolts. That's the arc-venting envelope — pack it tighter and you risk flashover between adjacent metalwork. The arcing time is 10-15 ms, so the plasma clears fast, but the clearance numbers are the minimum, not a suggestion. Power wiring accepts 70-240 mm² stranded cable on the main terminals — that's substantial, roughly 2/0 to 500 MCM in AWG terms. The coil wiring is screw-type terminals accepting 2x 0.5-1.5 mm² solid or 2x 0.75-2.5 mm² stranded, with a max of 2x 4 mm². That's standard for control wiring; no special ferrules needed.","metaTitle":"Siemens 3RT1064-6AM36 SIRIUS Power Contactor, S10 Size, 200-","metaDescription":"Siemens 3RT1064-6AM36 SIRIUS power contactor, S10 size, 200-220 V AC coil, screw terminals. Active production. 202 mm depth, 145 mm width, 210 mm height. AC-3 switching up to 500 o","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"202 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"145 mm","at AC":"40 ... 80 ms","at DC":"40 ... 80 ms","title":"3RT1064-6AM36","Height":"210 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"70 ... 240 mm²","at 50 Hz":"0.9","at 60 Hz":"0.9","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"200 ... 220 V","description":"power contactor, AC-3e/AC-3 225 A, 110 kW / 400 V AC (50-60 Hz) / DC Uc: 200-220 V 3-pole, auxiliary contacts 2 NO + 2 NC drive: conventional main circuit: busbar control and auxiliary circuit: screw terminal","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Number Of Holes":"1","at AC-1 maximum":"750 1/h","at AC-2 maximum":"250 1/h","at AC-3 maximum":"500 1/h","at AC-4 maximum":"130 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","at AC-3e maximum":"500 1/h","Diameter Of Holes":"11 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S10","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 440 V rated value":"1.4 A","at 480 V rated value":"180 A","at 50 Hz rated value":"200 ... 220 V","at 500 V rated value":"2 A","at 60 Hz rated value":"200 ... 220 V","at 600 V rated value":"192 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"90 kW","For Auxiliary Contacts":"18 ... 14","Width Of Connection Bar":"25 mm","For Main Current Circuit":"Connection bar","at 200/208 V rated value":"60 hp","at 220/230 V rated value":"75 hp","at 460/480 V rated value":"150 hp","at 575/600 V rated value":"200 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Thickness Of Connection Bar":"6 mm","at AC-3 rated value maximum":"1 000 V","at AC in hot operating state":"51 W","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"195 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"05/01/2012","Design Of The Surge Suppressor":"with varistor","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"242 A","at AC-5b up to 400 V rated value":"186 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 400 A (690 V, 100 kA), aM: 315 A (690 V, 50 kA), BS88: 400 A (415 V, 50 kA)","Without Load Current Share Typical":"7.4 W","closing power of magnet coil at DC":"650 W","holding power of magnet coil at DC":"7.4 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 500 A (690 V, 100 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"17 W","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Limited To 1 S Switching At Zero Current Maximum":"4 000 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"2 807 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"2 082 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"1 397 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"1 144 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"150 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$341.63","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/69b9a398fba4613597a6a850761204d2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=353883&mlfb=3RT1064-6AM36"},"ai":{"faq":[{"question":"What is the depth of this contactor for panel layout?","answer":"The depth is 202 mm. That's the body depth from the mounting surface to the front of the arc chamber; add clearance for wiring bends and the 20 mm forward arc-venting gap."},{"question":"What wire sizes does the main power circuit accept?","answer":"The main terminals accept 70-240 mm² stranded cable. The coil terminals accept 2x 0.5-1.5 mm² solid or 2x 0.75-2.5 mm² stranded, max 2x 4 mm²."},{"question":"What operating temperature range does this contactor support?","answer":"During operation it's rated for -25 to +60 °C ambient. Storage range is -55 to +80 °C. The operating range covers most indoor panel environments; derate above 60 °C per the thermal curve."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1064-6AM36","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1064-6AM36 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}