{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1064-6PF35","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1064-6PF35","canonicalUrl":"https://aoctrl.com/siemens/3RT1064-6PF35","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1064-6PF35","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT1064-6PF35 power contactor, size S10, 96-127 VAC coil voltage, screw-type terminals, 202 mm depth, 165 mm width, 210 mm height.","salesMarkdown":"## SIRIUS S10 power contactor — 96-127 VAC coil, screw terminals The Siemens 3RT1064-6PF35 is a SIRIUS-brand power contactor in the S10 frame size, designed for motor switching and resistive load control in industrial control panels. The coil is rated for 96-127 VAC, with screw-type terminals for the magnet coil connection. Its mounting position allows a vertical surface with ±90° rotation and ±22.5° tilt front-to-back, giving flexibility in dense panel layouts where gland-plate clearance or busbar routing constrains orientation. ## Panel footprint and wiring capacity The contactor occupies 165 mm width, 210 mm height, and 202 mm depth — the depth dimension matters when the panel backplate is close to the enclosure door or when a shrouded busbar system runs behind the contactor. Side clearance of 10 mm and forward clearance of 20 mm are required for arc dissipation and airflow. Power circuit wiring accepts stranded conductors from 70 to 240 mm²; control circuit terminals handle solid or stranded wire in ranges from 0.5 mm² up to 4 mm² per clamp. The main terminals use a single 11 mm diameter hole for bolted bus or cable lug connections. ## Coil draw and operational limits The coil operates on a 96-127 VAC supply with an 80-100 ms pick-up and drop-out time, both AC and DC. The arcing time is 10-15 ms, which factors into contact wear calculations for switching inductive loads. Ambient operating range is -25 to +60 °C; storage extends from -55 to +80 °C. The rated switching frequency varies by duty: up to 750 operations/hour at AC-1, 500/h at AC-3, and 130/h at AC-4, reflecting the thermal recovery time between arcs.","metaTitle":"Siemens 3RT1064-6PF35 SIRIUS Contactor, 96-127 VAC Coil, S10","metaDescription":"Siemens 3RT1064-6PF35 SIRIUS power contactor, size S10, 96-127 VAC coil, screw terminals. Active production. Sourced to order. Depth 202 mm, width 165 mm.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"202 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"165 mm","at AC":"80 ... 100 ms","at DC":"80 ... 100 ms","title":"3RT1064-6PF35","Height":"210 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"70 ... 240 mm²","at 50 Hz":"0.4","at 60 Hz":"0.4","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"96 ... 127 V","description":"power contactor, AC-3e/AC-3 225 A, 110 kW / 400 V AC (50-60 Hz) / DC Uc: 96-127 V PLC input 24 V DC 3-pole, auxiliary contacts 1 NO + 1 NC drive: electronic main circuit: busbar control and auxiliary circuit: screw terminal with remaining lifetime indicator","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Number Of Holes":"1","at AC-1 maximum":"750 1/h","at AC-2 maximum":"250 1/h","at AC-3 maximum":"500 1/h","at AC-4 maximum":"130 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","at AC-3e maximum":"500 1/h","Diameter Of Holes":"11 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S10","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 440 V rated value":"1.4 A","at 480 V rated value":"180 A","at 50 Hz rated value":"96 ... 127 V","at 500 V rated value":"2 A","at 60 Hz rated value":"96 ... 127 V","at 600 V rated value":"192 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"90 kW","For Auxiliary Contacts":"18 ... 14","Width Of Connection Bar":"25 mm","For Main Current Circuit":"Connection bar","at 200/208 V rated value":"60 hp","at 220/230 V rated value":"75 hp","at 460/480 V rated value":"150 hp","at 575/600 V rated value":"200 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Thickness Of Connection Bar":"6 mm","at AC-3 rated value maximum":"1 000 V","at AC in hot operating state":"51 W","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"195 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"05/01/2012","Design Of The Surge Suppressor":"with varistor","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"242 A","at AC-5b up to 400 V rated value":"186 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 400 A (690 V, 100 kA), aM: 315 A (690 V, 50 kA), BS88: 400 A (415 V, 50 kA)","Without Load Current Share Typical":"3.4 W","closing power of magnet coil at DC":"580 W","holding power of magnet coil at DC":"3.4 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 500 A (690 V, 100 kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"17 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","voltage at PLC-control input rated value":"24 V","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Limited To 1 S Switching At Zero Current Maximum":"4 000 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"2 807 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"2 082 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"1 397 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"1 144 A; Use minimum cross-section acc. to AC-1 rated value","type of PLC-control input according to IEC 60947-1":"Type 2","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","operating range factor of the voltage at PLC-control input":"0.8 ... 1.1","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","for short-circuit protection of the RLT relay output required":"miniature fuse: 4 A FF (230 V, Ik= 400 A)","minimum cross-section in main circuit at maximum AC-1 rated value":"150 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0477bdc98e1eb51e81c78409e72d89ba.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=363758&mlfb=3RT1064-6PF35"},"ai":{"faq":[{"question":"What is 3RT1064-6PF35's listed depth on this Contactors line?","answer":"The depth is 202 mm, with a width of 165 mm and height of 210 mm. These dimensions are critical for panel layout and enclosure sizing."},{"question":"What coil voltage does 3RT1064-6PF35 require?","answer":"The coil is rated for 96-127 VAC. Connection uses screw-type terminals, and pick-up/drop-out times are 80-100 ms for both AC and DC supplies."},{"question":"How can I order 3RT1064-6PF35 or request a quote?","answer":"The contactor is sourced to order against the BOM quantity. Submit an RFQ for current availability and pricing — lead time is confirmed at that point."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1064-6PF35","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1064-6PF35 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}