{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1064-6XF46-0LA2","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1064-6XF46-0LA2","canonicalUrl":"https://aoctrl.com/siemens/3RT1064-6XF46-0LA2","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1064-6XF46-0LA2","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, power contactor, 3RT1064-6XF46-0LA2, size S10, 110 V DC coil, screw fixing, 202 mm depth, auxiliary switch.","salesMarkdown":"It carries a 110 V DC coil and includes an integrated auxiliary switch. Screw fixing and the 202 mm depth mean it mounts on a flat panel or DIN rail adapter plate — not a direct snap-on DIN rail mount, so plan for screw terminals and the gland plate clearance. The 145 mm width and 210 mm height fit a standard contactor footprint in the S10 frame class. The DC coil operates at 110 V rated value, with a dropout delay of 80 to 100 ms — that matters if you're coordinating with a safety relay or PLC output that needs to sequence off-delays. The auxiliary switch is rated 6 A at 24 V, 2 A at 48 V, 2 A at 60 V, 1 A at 110 V, and 0.9 A at 125 V, all DC. Use those figures to size your control-circuit fusing or electronic load; the switch is a standard form-C (changeover) contact, not a solid-state output. Mechanical life is typical 10,000,000 operations. ## Switching frequency by duty class Maximum switching rates: AC-1 (resistive) 700 ops/h, AC-2 (slip-ring motor) 250 ops/h, AC-3 (squirrel-cage motor) 500 ops/h, AC-4 (plugging/inching) 130 ops/h, AC-3e (enhanced AC-3) 500 ops/h. DC ratings: DC-1 350 ops/h, DC-3 and DC-5 both 250 ops/h. These numbers govern thermal load on the contact tips — don't exceed the AC-4 rate if you're reversing a conveyor several times a minute. ## Wire termination and mounting Terminals accept solid or stranded wire: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), max 2x (0.75 to 4 mm²). One mounting hole, 11 mm diameter. Screw fixing only — no spring-cage option on this variant. The S10 frame is a common size across the SIRIUS family, so panel cutouts and busbar kits for the 3RT1 series are compatible.","metaTitle":"Siemens 3RT1064-6XF46-0LA2 SIRIUS Power Contactor, 110 VDC C","metaDescription":"Siemens SIRIUS 3RT1064-6XF46-0LA2 power contactor, 110 VDC coil, size S10. Screw fixing, 202 mm depth. Auxiliary switch included. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"202 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"145 mm","at DC":"80 ... 100 ms","Height":"210 mm","Upwards":"10 mm","Forwards":"20 mm","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"110 V","Initial Value":"0.7","During Storage":"-55 ... +80 °C","Number Of Holes":"1","Type Of Voltage":"DC","at AC-1 maximum":"700 1/h","at AC-2 maximum":"250 1/h","at AC-3 maximum":"500 1/h","at AC-4 maximum":"130 1/h","at DC-1 maximum":"350 1/h","at DC-3 maximum":"250 1/h","at DC-5 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-40 ... +70 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.25","at AC-3e maximum":"500 1/h","Diameter Of Holes":"11 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S10","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"6 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 480 V rated value":"180 A","at 500 V rated value":"2 A","at 600 V rated value":"182 A","at 690 V rated value":"82 kW","Design Of The Product":"With extended operating range","Instantaneous Contact":"2","Side-By-Side Mounting":"Yes","at 1000 V rated value":"90 kW","For Auxiliary Contacts":"18 ... 14","Width Of Connection Bar":"25 mm","For Main Current Circuit":"screw-type terminals","at 200/208 V rated value":"60 hp","at 220/230 V rated value":"75 hp","at 460/480 V rated value":"150 hp","at 575/600 V rated value":"200 hp","at AC-2 at AC-3e maximum":"250 1/h","Relative Humidity Minimum":"10 %","at maximum Ith rated value":"150 mm²","Of Main Circuit Rated Value":"8 kV","Thickness Of Connection Bar":"6 mm","at AC-3 rated value maximum":"1 000 V","at maximum AC-1 rated value":"150 mm²","at AC in hot operating state":"51 W","at AC-2 at 400 V rated value":"110 kW","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"195 A","Substance Prohibitance (Date)":"09/06/2016","Design Of The Surge Suppressor":"with varistor","at AWG cables for main contacts":"2/0 ... 500 kcmil","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","Product Function Bus Communication":"No","With Type Of Assignment 2 Required":"gG: 400 A (690 V, 100 kA), aM: 315 A (690 V, 50 kA), BS88: 400 A (415 V, 50 kA)","Without Load Current Share Typical":"3.4 W","closing power of magnet coil at DC":"580 W","holding power of magnet coil at DC":"3.4 W","With Type Of Coordination 1 Required":"gG: 500 A (690 V, 100 kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"17 W","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","voltage at PLC-control input rated value":"24 V","Product Function Short Circuit Protection":"No","mirror contact according to IEC 60947-4-1":"Yes","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"2","Type Of Voltage Of The Control Supply Voltage":"DC","up to 40 °C according to IEC 60077 rated value":"275 A","up to 70 °C according to IEC 60077 rated value":"215 A","Limited To 1 S Switching At Zero Current Maximum":"4 000 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"2 807 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"2 082 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"1 397 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"1 144 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=725744&mlfb=3RT1064-6XF46-0LA2","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1064-6XF46-0LA2/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RT1064-6XF46-0LA2?","answer":"Submit an RFQ through this listing. Pricing and stock are confirmed at quote time through independent distribution channels."},{"question":"What is the closest functional second-source for 3RT1064-6XF46-0LA2?","answer":"The 3RT1264-6AP36-0KA1 is a peer in the SIRIUS family with a similar S10 frame and auxiliary contact configuration, but it uses a different coil voltage and terminal layout. Verify coil voltage and wiring before substitution — the 3RT1064-6XF46-0LA2 has a 110 V DC coil and screw fixing, which may not match the peer's specs."},{"question":"What is the depth of 3RT1064-6XF46-0LA2?","answer":"The depth is 202 mm. Width is 145 mm, height is 210 mm. These dimensions are for the contactor body without auxiliary blocks or busbar adapters."},{"question":"What wire sizes does 3RT1064-6XF46-0LA2 accept?","answer":"Solid or stranded wire: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), and max 2x (0.75 to 4 mm²). The terminals are screw-type, not spring-cage."},{"question":"Will 3RT1064-6XF46-0LA2 drop into a panel specified for 3RT1264-6AP36-0KA1 without rewiring?","answer":"The S10 frame size and mounting hole pattern are shared across the 3RT1 series, so the physical footprint matches. However, the coil voltage differs — 3RT1064-6XF46-0LA2 uses 110 V DC — and the terminal arrangement may not be identical. Check the wiring diagram before swapping."},{"question":"What compliance documentation does Siemens provide for 3RT1064-6XF46-0LA2?","answer":"As a SIRIUS product, it carries CE marking and is manufactured under IEC/EN 60947-4-1. RoHS and REACH declarations are available from Siemens upon request. UL and CSA listings are typical for the SIRIUS contactor range, but verify the specific file number for this order code."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1064-6XF46-0LA2","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1064-6XF46-0LA2 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}