{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1066-6SF36","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1066-6SF36","canonicalUrl":"https://aoctrl.com/siemens/3RT1066-6SF36","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1066-6SF36","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT1066-6SF36 power contactor, size S10, 96-127 VAC/VDC coil, screw-type terminals, 145 mm width, 202 mm depth, 210 mm height.","salesMarkdown":"## SIRIUS S10 power contactor — current-production, 96-127 V coil The 3RT1066-6SF36: This wire range covers the majority of motor feeder and distribution panel builds without needing adapter lugs. ## Physical envelope and panel integration The contactor measures 145 mm wide by 202 mm deep by 210 mm high, with screw fixing as the fastening method. These are the minimum air gaps to adjacent metalwork or enclosures for proper arc quenching and heat dissipation; a panel builder should budget these into the gland plate and busbar layout. ## Switching performance and mechanical endurance The arcing time is 10-15 ms, and the opening/closing times are 115-130 ms for both AC and DC operation. Maximum switching rates: 500 operations per hour in AC-1 and AC-3 duty, 250/h in AC-2, and 130/h in AC-4. For AC-3e the rate is also 500/h. These limits govern the contactor's suitability for frequent start-stop cycles — a conveyor or pump with repeated jogging will need to stay within the AC-4 ceiling of 130 operations per hour. The listed MTBF is 75 years, and the typical mechanical life of the contactor is 10,000,000 operations. The auxiliary switch is included as standard, which simplifies BOM consolidation for control circuits that need a feedback contact.","metaTitle":"Siemens 3RT1066-6SF36 SIRIUS Power Contactor, S10","metaDescription":"Siemens 3RT1066-6SF36 SIRIUS power contactor, size S10, 96-127 VAC coil, screw terminals, MTBF 75 a. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"MTBF":"75 a","Depth":"202 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"145 mm","at AC":"115 ... 130 ms","at DC":"115 ... 130 ms","title":"3RT1066-6SF36","Height":"210 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"70 ... 240 mm²","at 50 Hz":"0.4","at 60 Hz":"0.4","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"96 ... 127 V","description":"power contactor, AC-3e/AC-3 300 A, 160 kW / 400 V, AC (50-60 Hz) / DC 96-127 V x (0.8-1.1) F-PLC input 24 V DC 3-pole, auxiliary contacts 2 NO + 2 NC drive: electronic main circuit: busbar control and auxiliary circuit: screw terminal","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Number Of Holes":"1","at AC-1 maximum":"500 1/h","at AC-2 maximum":"250 1/h","at AC-3 maximum":"500 1/h","at AC-4 maximum":"130 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","at AC-3e maximum":"500 1/h","Diameter Of Holes":"11 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S10","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 440 V rated value":"1.4 A","at 480 V rated value":"302 A","at 50 Hz rated value":"96 ... 127 V","at 500 V rated value":"2 A","at 60 Hz rated value":"96 ... 127 V","at 600 V rated value":"289 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"132 kW","For Auxiliary Contacts":"18 ... 14","Width Of Connection Bar":"25 mm","For Main Current Circuit":"Connection bar","at 200/208 V rated value":"100 hp","at 220/230 V rated value":"125 hp","at 460/480 V rated value":"250 hp","at 575/600 V rated value":"300 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Safe failure fraction (SFF)":"93 %","Safety-Related Switching On":"No","Thickness Of Connection Bar":"6 mm","at AC-3 rated value maximum":"1 000 V","at AC in hot operating state":"66 W","at AC-2 at 400 V rated value":"160 kW","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"280 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"03/01/2017","Design Of The Surge Suppressor":"with varistor","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"290 A","at AC-5b up to 400 V rated value":"249 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 400 A (690 V, 100 kA), aM: 315 A (690 V, 50 kA), BS88: 400 A (415 V, 50 kA)","Without Load Current Share Typical":"3.4 W","closing power of magnet coil at DC":"580 W","holding power of magnet coil at DC":"3.4 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 500 A (690 V, 100 kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","category according to EN ISO 13849-1":"2","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"22 W","stop category according to EN 60204-1":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","voltage at PLC-control input rated value":"24 V","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Recovery Time After Power Failure Typical":"2 s","mirror contact according to IEC 60947-4-1":"Yes","safety device type according to IEC 61508-2":"Type B","Type Of Voltage Of The Control Supply Voltage":"AC/DC","hardware fault tolerance according to IEC 61508":"0","Limited To 1 S Switching At Zero Current Maximum":"5 524 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"4 579 A; Use minimum cross-section acc. to AC-1 rated value","PFHD with high demand rate according to EN 62061":"4.5E-7 1/h","Limited To 10 S Switching At Zero Current Maximum":"3 153 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"1 883 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"1 445 A; Use minimum cross-section acc. to AC-1 rated value","SIL Claim Limit (subsystem) according to EN 62061":"2","PFDavg with low demand rate according to IEC 61508":"0.007","performance level (PL) according to EN ISO 13849-1":"c","type of PLC-control input according to IEC 60947-1":"Type 1","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","operating range factor of the voltage at PLC-control input":"0.8 ... 1.1","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"185 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/650ea87cc2692f38b7b250ca219e56f2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=907606&mlfb=3RT1066-6SF36"},"ai":{"faq":[{"question":"What is the MTBF of the 3RT1066-6SF36?","answer":"The listed MTBF is 75 years. This is a calculated reliability figure under defined operating conditions and should be used as a comparative metric rather than a guaranteed service life."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1066-6SF36","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1066-6SF36 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}