{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1066-6SF36-3PA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1066-6SF36-3PA0","canonicalUrl":"https://aoctrl.com/siemens/3RT1066-6SF36-3PA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1066-6SF36-3PA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S10, 3RT1066-6SF36-3PA0, coil 96-127 V AC, MTBF 75 a.","salesMarkdown":"It's rated for continuous duty in control panels and motor circuits, with an MTBF of 75 a that tells you this part was designed for long service intervals — a good sign if you're freezing a BOM for a line that runs 24/7. The coil operates on 96-127 V AC, with a pickup threshold of 0.8 x rated value and a dropout around 0.4 x rated value at both 50 and 60 Hz. That means it holds in reliably down to about 77 V AC and drops out below 38 V AC — useful if your mill supply sags under a heavy motor start. Switching rates: up to 500 operations per hour for AC-1, AC-3, and AC-3e duty, 250 for AC-2, and 130 for AC-4. Auxiliary contacts are rated at 10 A at 24 V, 2 A at 48 V, and 2 A at 60 V — enough for signaling back to a PLC input or a control relay. Mounting is by screw fixing through an 11 mm hole. The contactor measures 210 mm high, 145 mm wide, and 202 mm deep. Main power terminals accept stranded cable from 70 to 240 mm².","metaTitle":"Siemens 3RT1066-6SF36-3PA0 SIRIUS Power Contactor, Size S10,","metaDescription":"Siemens SIRIUS power contactor 3RT1066-6SF36-3PA0, size S10, coil 96-127 V AC, MTBF 75 a. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"MTBF":"75 a","Depth":"202 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"145 mm","at AC":"115 ... 130 ms","at DC":"115 ... 130 ms","title":"3RT1066-6SF36-3PA0","Height":"210 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"70 ... 240 mm²","at 50 Hz":"0.4","at 60 Hz":"0.4","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"96 ... 127 V","description":"power contactor, AC-3e/AC-3 300 A, 160 kW / 400 V, AC (50-60 Hz) / DC 96-127 V x (0.8-1.1) F-PLC input 24 V DC 3-pole, auxiliary contacts 2 NO + 2 NC permanently mounted drive: electronic main circuit: busbar control and auxiliary circuit: screw terminal","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Number Of Holes":"1","at AC-1 maximum":"500 1/h","at AC-2 maximum":"250 1/h","at AC-3 maximum":"500 1/h","at AC-4 maximum":"130 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","at AC-3e maximum":"500 1/h","Diameter Of Holes":"11 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S10","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 440 V rated value":"1.4 A","at 480 V rated value":"302 A","at 50 Hz rated value":"96 ... 127 V","at 500 V rated value":"2 A","at 60 Hz rated value":"96 ... 127 V","at 600 V rated value":"289 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"132 kW","For Auxiliary Contacts":"18 ... 14","Width Of Connection Bar":"25 mm","For Main Current Circuit":"Connection bar","at 200/208 V rated value":"100 hp","at 220/230 V rated value":"125 hp","at 460/480 V rated value":"250 hp","at 575/600 V rated value":"300 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Safe failure fraction (SFF)":"93 %","Safety-Related Switching On":"No","Thickness Of Connection Bar":"6 mm","at AC-3 rated value maximum":"1 000 V","at AC in hot operating state":"66 W","at AC-2 at 400 V rated value":"160 kW","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"280 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"03/01/2017","Design Of The Surge Suppressor":"with varistor","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"290 A","at AC-5b up to 400 V rated value":"249 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 400 A (690 V, 100 kA), aM: 315 A (690 V, 50 kA), BS88: 400 A (415 V, 50 kA)","Without Load Current Share Typical":"3.4 W","closing power of magnet coil at DC":"580 W","holding power of magnet coil at DC":"3.4 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 500 A (690 V, 100 kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","category according to EN ISO 13849-1":"2","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"22 W","stop category according to EN 60204-1":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","voltage at PLC-control input rated value":"24 V","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Recovery Time After Power Failure Typical":"2 s","mirror contact according to IEC 60947-4-1":"Yes","safety device type according to IEC 61508-2":"Type B","Type Of Voltage Of The Control Supply Voltage":"AC/DC","hardware fault tolerance according to IEC 61508":"0","Limited To 1 S Switching At Zero Current Maximum":"5 524 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"4 579 A; Use minimum cross-section acc. to AC-1 rated value","PFHD with high demand rate according to EN 62061":"4.5E-7 1/h","Limited To 10 S Switching At Zero Current Maximum":"3 153 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"1 883 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"1 445 A; Use minimum cross-section acc. to AC-1 rated value","SIL Claim Limit (subsystem) according to EN 62061":"2","PFDavg with low demand rate according to IEC 61508":"0.007","performance level (PL) according to EN ISO 13849-1":"c","type of PLC-control input according to IEC 60947-1":"Type 1","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","operating range factor of the voltage at PLC-control input":"0.8 ... 1.1","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"185 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$99.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e9130e30586dae44084d56f7a8029767.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=907607&mlfb=3RT1066-6SF36-3PA0"},"ai":{"faq":[{"question":"What is the MTBF of this contactor?","answer":"The MTBF is listed as 75 a."},{"question":"What are the key dimensions and mounting clearances?","answer":"Height 210 mm, width 145 mm, depth 202 mm. Clearances: 10 mm up, 10 mm down, 20 mm forward, 10 mm side. Mounted by screw fixing through an 11 mm hole."},{"question":"What coil voltage does this contactor use?","answer":"96-127 V AC coil, with screw-type terminals. Pickup at 0.8 x rated, dropout at 0.4 x rated (50/60 Hz)."},{"question":"Does it have an auxiliary switch?","answer":"Yes, it includes an auxiliary switch rated 10 A at 24 V, 2 A at 48 V, and 2 A at 60 V."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1066-6SF36-3PA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1066-6SF36-3PA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}