{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1075-2NP36","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1075-2NP36","canonicalUrl":"https://aoctrl.com/siemens/3RT1075-2NP36","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1075-2NP36","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT1075-2NP36 power contactor, S12 size, screw fixing, spring-type coil terminals, 225 mm depth, 214 mm height, 160 mm width.","salesMarkdown":"## S12 frame power switching for motor and resistive loads The Siemens 3RT1075-2NP36 is a SIRIUS-brand power contactor in the S12 frame size — the largest standard contactor footprint in the SIRIUS family, sized for high-current motor switching and resistive load control up to the AC-1 duty cycle limits. Switching frequency varies by duty class: 700 operations per hour maximum in AC-1 (resistive), 500 in AC-3 (motor start/run), 200 in AC-2 (slip-ring motor), and 130 in AC-4 (plugging/inching). The AC-3e rating mirrors the AC-3 ceiling at 500 ops/h. ## Panel mounting and wiring constraints The coil termination uses spring-type terminals — no screw torque to manage there. Clearance requirements around the contactor: 10 mm upwards and downwards, 20 mm forwards, 10 mm at each side — these are minimum distances for natural convection cooling at rated current; crowding closer than these figures forces derating. ## Coil drive and timing for control logic This wide tolerance covers most global 208–277 V industrial supplies without a separate control transformer. These timing windows matter for control sequences where multiple contactors must close in a defined order or where arc-fault detection thresholds are set. ## Sourcing and lifecycle position The lifecycle stage is listed as current — meaning the manufacturer continues to produce this order code as an active catalog item.","metaTitle":"Siemens 3RT1075-2NP36 SIRIUS Power Contactor, S12","metaDescription":"Siemens 3RT1075-2NP36 SIRIUS power contactor, S12 size, 225 mm depth, 214 mm height, 160 mm width. Screw fixing, spring-type coil terminals.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"225 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"160 mm","at AC":"80 ... 100 ms","at DC":"80 ... 100 ms","title":"3RT1075-2NP36","Height":"214 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"70 ... 240 mm²","at 50 Hz":"0.4","at 60 Hz":"0.4","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"200 ... 277 V","description":"power contactor, AC-3e/AC-3 400 A, 200 kW / 400 V AC (50-60 Hz) / DC Uc: 200-277 V PLC input 24 V DC 3-pole, auxiliary contacts 2 NO + 2 NC drive: electronic main circuit: busbar control and auxiliary circuit: spring-loaded terminal","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","Number Of Holes":"1","at AC-1 maximum":"700 1/h","at AC-2 maximum":"200 1/h","at AC-3 maximum":"500 1/h","at AC-4 maximum":"130 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","at AC-3e maximum":"500 1/h","Diameter Of Holes":"11 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S12","Solid Or Stranded":"2x (0,25 ... 2,5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 440 V rated value":"1.4 A","at 480 V rated value":"361 A","at 50 Hz rated value":"200 ... 277 V","at 500 V rated value":"2 A","at 60 Hz rated value":"200 ... 277 V","at 600 V rated value":"382 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"250 kW","For Auxiliary Contacts":"24 ... 14","Width Of Connection Bar":"25 mm","For Main Current Circuit":"Connection bar","at 200/208 V rated value":"125 hp","at 220/230 V rated value":"150 hp","at 460/480 V rated value":"300 hp","at 575/600 V rated value":"400 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Thickness Of Connection Bar":"6 mm","at AC-3 rated value maximum":"1 000 V","at AC in hot operating state":"105 W","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"350 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"05/01/2012","Design Of The Surge Suppressor":"with varistor","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"378 A","at AC-5b up to 400 V rated value":"332 A","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 500 A (690 V, 100 kA), aM: 400 A (690 V, 50 kA), BS88: 450 A (415 V, 50 kA)","Without Load Current Share Typical":"3.6 W","closing power of magnet coil at DC":"800 W","holding power of magnet coil at DC":"3.6 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","With Type Of Coordination 1 Required":"gG: 630 A (690 V, 100 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"35 W","for AWG cables for auxiliary contacts":"2x (24 ... 14)","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","voltage at PLC-control input rated value":"24 V","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Limited To 1 S Switching At Zero Current Maximum":"6 600 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"5 761 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"4 143 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"2 635 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"2 088 A; Use minimum cross-section acc. to AC-1 rated value","type of PLC-control input according to IEC 60947-1":"Type 2","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","operating range factor of the voltage at PLC-control input":"0.8 ... 1.1","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"300 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5605008613b98af874e26081586c81fd.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=310394&mlfb=3RT1075-2NP36"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1075-2NP36","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1075-2NP36 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}