{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1075-6AT36","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1075-6AT36","canonicalUrl":"https://aoctrl.com/siemens/3RT1075-6AT36","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1075-6AT36","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S12, order code 3RT1075-6AT36, screw fixing, 225 mm depth, main circuit 70-240 mm² stranded.","salesMarkdown":"It's a current-production part, so it's still a standard BOM line item, not a scavenger hunt. The main power circuit accepts stranded conductors from 70 up to 240 mm², which is the range you'd expect for feeding a large motor or a distribution bus through the contactor. The auxiliary contact block handles 10 A at 24 V rated value, 2 A at 48 V or 60 V, and 1 A at 110 V — enough for a PLC input or a status lamp, but not for driving another contactor coil directly without checking the inrush. Switching frequency varies by duty class: up to 700 operations per hour at AC-1 (resistive), 500 at AC-3 (squirrel-cage motor starting), and 130 at AC-4 (plugging/inching). Mounts via screw fixing — four 11 mm holes on a standard pattern for the S12 frame. Depth is 225 mm, so check your enclosure depth before committing; that's deeper than a typical S0 or S3 contactor. Width is 160 mm, height 214 mm. That covers most panel layouts, but if you're stacking multiple contactors side-by-side, the 10 mm side clearance is the minimum to maintain for heat dissipation. ## Control wiring and coil The magnet coil uses screw-type terminals. That's standard for control wiring — 1.5 mm² for signal, 2.5 mm² for coil feeds. That's fast enough for most safety circuits but not instantaneous — if you need a faster break, you'd add a forced-guided contactor or a safety relay.","metaTitle":"Siemens 3RT1075-6AT36 SIRIUS Power Contactor, S12, 225 mm de","metaDescription":"Siemens 3RT1075-6AT36 SIRIUS power contactor, size S12, 225 mm depth, screw fixing, 70-240 mm² main circuit, currently in production. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"225 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"160 mm","at AC":"60 ... 100 ms","at DC":"60 ... 100 ms","title":"3RT1075-6AT36","Height":"214 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"70 ... 240 mm²","at 50 Hz":"0.9","at 60 Hz":"0.9","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"575 ... 600 V","description":"power contactor, AC-3e/AC-3 400 A, 200 kW / 400 V AC (50-60 Hz) / DC Uc: 575-600 V 3-pole, auxiliary contacts 2 NO + 2 NC drive: conventional main circuit: busbar control and auxiliary circuit: screw terminal","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Number Of Holes":"1","at AC-1 maximum":"700 1/h","at AC-2 maximum":"200 1/h","at AC-3 maximum":"500 1/h","at AC-4 maximum":"130 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","at AC-3e maximum":"500 1/h","Diameter Of Holes":"11 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S12","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 440 V rated value":"1.4 A","at 480 V rated value":"361 A","at 50 Hz rated value":"575 ... 600 V","at 500 V rated value":"2 A","at 60 Hz rated value":"575 ... 600 V","at 600 V rated value":"382 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"250 kW","For Auxiliary Contacts":"18 ... 14","Width Of Connection Bar":"25 mm","For Main Current Circuit":"Connection bar","at 200/208 V rated value":"125 hp","at 220/230 V rated value":"150 hp","at 460/480 V rated value":"300 hp","at 575/600 V rated value":"400 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Thickness Of Connection Bar":"6 mm","at AC-3 rated value maximum":"1 000 V","at AC in hot operating state":"105 W","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"350 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"05/01/2012","Design Of The Surge Suppressor":"with varistor","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"378 A","at AC-5b up to 400 V rated value":"332 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 500 A (690 V, 100 kA), aM: 400 A (690 V, 50 kA), BS88: 450 A (415 V, 50 kA)","Without Load Current Share Typical":"10 W","closing power of magnet coil at DC":"920 W","holding power of magnet coil at DC":"10 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 630 A (690 V, 100 kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"35 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Limited To 1 S Switching At Zero Current Maximum":"6 600 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"5 761 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"4 143 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"2 635 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"2 088 A; Use minimum cross-section acc. to AC-1 rated value","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"300 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/51f1ddee546ce9238a3ce49c2a72eb01.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=128593&mlfb=3RT1075-6AT36"},"ai":{"faq":[{"question":"What is the depth of the 3RT1075-6AT36?","answer":"The depth is 225 mm. That's the dimension from the mounting surface to the furthest forward point of the contactor."},{"question":"What wire sizes does the main circuit accept?","answer":"The main power circuit accepts stranded conductors from 70 to 240 mm². The control circuit accepts solid or stranded from 0.5 to 4 mm² per terminal."},{"question":"Will the 3RT1075-6AT36 drop into a panel designed for the 3RT1075-2AU36?","answer":"Mechanically yes — same S12 frame, same screw-fixing pattern, same 225 mm depth. The difference is the coil voltage; verify that matches your control circuit before installing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1075-6AT36","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1075-6AT36 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}