{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1075-6PF35","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1075-6PF35","canonicalUrl":"https://aoctrl.com/siemens/3RT1075-6PF35","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1075-6PF35","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, Size S12, 3RT1075-6PF35, 96-127 V AC coil, screw-type terminals, 700 A AC-1, 225 mm depth.","salesMarkdown":"The coil voltage range is 96-127 V AC. Screw-type coil terminals simplify field wiring. The AC-1 rating (resistive load) governs continuous current capacity at 700 A — that's the number to size main power conductors and fusing. AC-3 (motor starting) and AC-4 (plugging/inching) ratings are lower; for motor duty, the AC-3 switching frequency of 500 operations per hour sets the thermal limit for repetitive starts. The arcing time of 10-15 ms is typical for this frame size and informs arc-flash coordination studies. Electrical life depends on the load; for AC-3 duty expect roughly 1-2 million cycles before contact inspection is due. The auxiliary switch is built in, rated at 10 A at 24 V, 2 A at 48-60 V, and 1 A at 110 V — enough to drive a PLC input or a small relay directly. Mounting is screw fixing with a vertical surface orientation; the contactor can be rotated ±90° or tilted ±22.5° forward/back. That flexibility helps in tight enclosures where the busbars or cables dictate the orientation. The footprint is 214 mm high × 180 mm wide × 225 mm deep — allow 10 mm clearance above and below, 20 mm forward, and 10 mm at the sides for arc venting and airflow. Power terminals accept stranded cable from 70 mm² up to 240 mm² — that's the range for the main circuit. The auxiliary/coil terminals are screw-type, accepting 2× (0.5-1.5 mm²) solid or 2× (0.75-2.5 mm²) stranded, max 2× 4 mm². A single 11 mm diameter mounting hole is provided for the screw fix. No end-of-life notice or last-time-buy date is available.","metaTitle":"Siemens 3RT1075-6PF35 SIRIUS Power Contactor, Size S12, 96-1","metaDescription":"Siemens 3RT1075-6PF35 SIRIUS power contactor, Size S12, 96-127 V AC coil, screw terminals. Rated for 700 A AC-1. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"225 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"180 mm","at AC":"80 ... 100 ms","at DC":"80 ... 100 ms","title":"3RT1075-6PF35","Height":"214 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"70 ... 240 mm²","at 50 Hz":"0.4","at 60 Hz":"0.4","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"96 ... 127 V","description":"power contactor, AC-3e/AC-3 400 A, 200 kW / 400 V AC (50-60 Hz) / DC Uc: 96-127 V PLC input 24 V DC 3-pole, auxiliary contacts 1 NO + 1 NC drive: electronic main circuit: busbar control and auxiliary circuit: screw terminal with remaining lifetime indicator","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Number Of Holes":"1","at AC-1 maximum":"700 1/h","at AC-2 maximum":"200 1/h","at AC-3 maximum":"500 1/h","at AC-4 maximum":"130 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","at AC-3e maximum":"500 1/h","Diameter Of Holes":"11 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S12","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 440 V rated value":"1.4 A","at 480 V rated value":"361 A","at 50 Hz rated value":"96 ... 127 V","at 500 V rated value":"2 A","at 60 Hz rated value":"96 ... 127 V","at 600 V rated value":"382 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"250 kW","For Auxiliary Contacts":"18 ... 14","Width Of Connection Bar":"25 mm","For Main Current Circuit":"Connection bar","at 200/208 V rated value":"125 hp","at 220/230 V rated value":"150 hp","at 460/480 V rated value":"300 hp","at 575/600 V rated value":"400 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Thickness Of Connection Bar":"6 mm","at AC-3 rated value maximum":"1 000 V","at AC in hot operating state":"105 W","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"350 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"05/01/2012","Design Of The Surge Suppressor":"with varistor","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"378 A","at AC-5b up to 400 V rated value":"332 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 500 A (690 V, 100 kA), aM: 400 A (690 V, 50 kA), BS88: 450 A (415 V, 50 kA)","Without Load Current Share Typical":"3.6 W","closing power of magnet coil at DC":"800 W","holding power of magnet coil at DC":"3.6 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 630 A (690 V, 100 kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"35 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","voltage at PLC-control input rated value":"24 V","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Limited To 1 S Switching At Zero Current Maximum":"6 600 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"5 761 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"4 143 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"2 635 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"2 088 A; Use minimum cross-section acc. to AC-1 rated value","type of PLC-control input according to IEC 60947-1":"Type 2","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","operating range factor of the voltage at PLC-control input":"0.8 ... 1.1","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","for short-circuit protection of the RLT relay output required":"miniature fuse: 4 A FF (230 V, Ik= 400 A)","minimum cross-section in main circuit at maximum AC-1 rated value":"300 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/20c06b1d65b8ebef8af8f856c86729b4.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=304386&mlfb=3RT1075-6PF35"},"ai":{"faq":[{"question":"What are the key dimensions of 3RT1075-6PF35?","answer":"The contactor measures 214 mm high × 180 mm wide × 225 mm deep. Mounting clearance: 10 mm above/below, 20 mm forward, 10 mm at sides."},{"question":"What wire sizes does the 3RT1075-6PF35 accept?","answer":"Main power terminals accept stranded cable 70-240 mm². Auxiliary and coil terminals accept 2× (0.5-1.5 mm²) solid or 2× (0.75-2.5 mm²) stranded, max 2× 4 mm². Coil terminals are screw-type."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1075-6PF35","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1075-6PF35 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}