{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1076-2NP36","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1076-2NP36","canonicalUrl":"https://aoctrl.com/siemens/3RT1076-2NP36","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1076-2NP36","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, power contactor, size S12, 200-277 V AC coil, spring-type terminals, screw fixing, 225 x 160 x 214 mm.","salesMarkdown":"## What this SIRIUS S12 contactor is It is a current-production part, actively manufactured. The magnet coil is rated for 200–277 V AC and terminates on spring-type terminals — no screw torque to verify, but the stripped length and ferrule size matter for a reliable hold. Coil pick-up and drop-out times run 80–100 ms on AC and DC alike, so don't expect a fast-acting contactor for precise load shedding; this is a general-purpose switching device. ## Duty-cycle and switching frequency Switching frequency varies sharply by duty class: AC-1 (resistive) allows 500 operations per hour, AC-3 (squirrel-cage motor start/run) drops to 420 ops/h, AC-2 (slip-ring motor) to 170 ops/h, and AC-4 (plugging/inching) to 130 ops/h. For a motor-switching application, the AC-3e rating at 420 ops/h is the one that governs real throughput — exceeding it accelerates contact wear. ## Auxiliary contacts and environmental limits An auxiliary switch is built in, rated 10 A at 24 V, 2 A at 48 V and 60 V, 1 A at 110 V — sufficient for signalling to a PLC input or a pilot light, but watch the voltage derating curve if you're switching DC inductive loads.","metaTitle":"Siemens 3RT1076-2NP36 SIRIUS Power Contactor, S12, 200-277V","metaDescription":"Siemens SIRIUS 3RT1076-2NP36 power contactor, size S12, 200-277 V AC coil, spring-type terminals. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"225 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"160 mm","at AC":"80 ... 100 ms","at DC":"80 ... 100 ms","title":"3RT1076-2NP36","Height":"214 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"70 ... 240 mm²","at 50 Hz":"0.4","at 60 Hz":"0.4","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"200 ... 277 V","description":"power contactor, AC-3e/AC-3 500 A, 250 kW / 400 V AC (50-60 Hz) / DC Uc: 200-277 V PLC input 24 V DC 3-pole, auxiliary contacts 2 NO + 2 NC drive: electronic main circuit: busbar control and auxiliary circuit: spring-loaded terminal","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","Number Of Holes":"1","at AC-1 maximum":"500 1/h","at AC-2 maximum":"170 1/h","at AC-3 maximum":"420 1/h","at AC-4 maximum":"130 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","at AC-3e maximum":"420 1/h","Diameter Of Holes":"11 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S12","Solid Or Stranded":"2x (0,25 ... 2,5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 440 V rated value":"1.4 A","at 480 V rated value":"477 A","at 50 Hz rated value":"200 ... 277 V","at 500 V rated value":"2 A","at 60 Hz rated value":"200 ... 277 V","at 600 V rated value":"472 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"250 kW","For Auxiliary Contacts":"24 ... 14","Width Of Connection Bar":"25 mm","For Main Current Circuit":"Connection bar","at 200/208 V rated value":"150 hp","at 220/230 V rated value":"200 hp","at 460/480 V rated value":"400 hp","at 575/600 V rated value":"500 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Thickness Of Connection Bar":"6 mm","at AC-3 rated value maximum":"1 000 V","at AC in hot operating state":"165 W","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"430 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"05/01/2012","Design Of The Surge Suppressor":"with varistor","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"536 A","at AC-5b up to 400 V rated value":"415 A","For Auxiliary And Control Circuit":"spring-loaded terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 500 A (690 V, 100 kA), aM: 500 A (690 V, 50 kA), BS88: 500 A (415 V, 50 kA)","Without Load Current Share Typical":"3.6 W","closing power of magnet coil at DC":"800 W","holding power of magnet coil at DC":"3.6 W","At Contactor For Auxiliary Contacts":"Spring-type terminals","With Type Of Coordination 1 Required":"gG: 630 A (690 V, 100 kA)","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"55 W","for AWG cables for auxiliary contacts":"2x (24 ... 14)","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","voltage at PLC-control input rated value":"24 V","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Limited To 1 S Switching At Zero Current Maximum":"7 484 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"7 484 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"5 978 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"3 765 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"2 887 A; Use minimum cross-section acc. to AC-1 rated value","type of PLC-control input according to IEC 60947-1":"Type 2","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","operating range factor of the voltage at PLC-control input":"0.8 ... 1.1","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"370 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6f101679d8343bfdb351dec4e5c3beb7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=206815&mlfb=3RT1076-2NP36"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"It is a size S12 power contactor with a 200–277 V AC coil, spring-type coil terminals, main power terminals accepting 70–240 mm² stranded cable, and an auxiliary switch rated 10 A at 24 V. Switching frequency reaches 420 ops/h in AC-3 duty."},{"question":"What compliance documentation is available for 3RT1076-2NP36?","answer":"As a Siemens SIRIUS product, it carries CE marking for the European market and is manufactured under IEC/EN 60947-4-1. UL and CSA listings are typical for this series; verify the specific certification on the nameplate or request the declaration of conformity with your RFQ."},{"question":"Will 3RT1076-2NP36 drop into a panel specified for 3RT2024-2BB40?","answer":"Not without checking the mounting and wiring. The 3RT1076-2NP36 uses screw fixing through an 11 mm hole, while the 3RT2024-2BB40 may mount on a DIN rail or a different bolt pattern. The terminal range (70–240 mm²) is heavier than smaller SIRIUS frames, so the lug size and bending radius in the panel must be verified. Always compare the dimensional drawing before assuming a drop-in swap."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1076-2NP36","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1076-2NP36 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}