{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1076-6AP36-0AE0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1076-6AP36-0AE0","canonicalUrl":"https://aoctrl.com/siemens/3RT1076-6AP36-0AE0","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1076-6AP36-0AE0","rawCanonicalId":null},"summary":{"shortDescription":"CONTACTOR, 250KW/400V/AC-3 AC(40...60HZ)/DC OPERATION UC 220-240V AUX.CONTACTS SOLID-STATE COMP.: 1NO+1NC, RIGHT, 1NO+1NC, LEFT COIL CONNECTIONS LEFT, BAR CONNECTIONS SPREADED, REDUCED OFF DELAY SPECIAL PURPOSE DEVICE","salesMarkdown":null,"metaTitle":"3RT1076-6AP36-0AE0 - Siemens","metaDescription":"CONTACTOR, 250KW/400V/AC-3 AC(40...60HZ)/DC OPERATION UC 220-240V AUX.CONTACTS SOLID-STATE COMP.: 1NO+1NC, RIGHT, 1NO+1NC, LEFT COIL CONNECTIONS LEFT, BAR CONNECTIONS SPREADED, REDUCED OFF DELAY SPECIAL PURPOSE DEVICE","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"225 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"160 mm","at AC":"60 ... 100 ms","at DC":"60 ... 100 ms","Height":"214 mm","Maximum":"2 000 m","Upwards":"10 mm","Forwards":"20 mm","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.8 ... 1.1","Downwards":"10 mm","Arcing time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"220 ... 240 V","On The Front":"IP00; IP20 on the front with cover / box terminal","Initial Value":"0.8","Mounting type":"screw fixing","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Number of holes":"1","Of The Terminal":"IP00","at AC-1 maximum":"500 1/h","at AC-2 maximum":"170 1/h","at AC-3 maximum":"420 1/h","at AC-4 maximum":"130 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Full-scale value":"1.1","Diameter of holes":"11 mm","Size of contactor":"S12","Product brand name":"SIRIUS","Product designation":"Power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"220 ... 240 V","at 500 V rated value":"315 kW","at 60 Hz rated value":"220 ... 240 V","at 690 V rated value":"148 kW","Instantaneous Contact":"2","Side-by-side mounting":"Yes","at 1000 V rated value":"250 kW","Width of connection bar":"25 mm","For Main Current Circuit":"Connection bar","Thickness of connection bar":"6 mm","at maximum AC-1 rated value":"370 mm²","at AC-2 at 400 V rated value":"291 kW","at AC-4 at 400 V rated value":"430 A","Design of the surge suppressor":"with varistor","at 230 V at 60 °C rated value":"151 kW","at 690 V at 60 °C rated value":"624 kW","at 1000 V at 60 °C rated value":"329 W","at AC-5a up to 690 V rated value":"536 A","at AC-5b up to 400 V rated value":"415 A","Closing power of magnet coil at DC":"920 W","Holding power of magnet coil at DC":"10 W","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 500 A","At Contactor For Auxiliary Contacts":"Screw-type terminals","at AWG conductors for main contacts":"2/0 ... 500 kcmil","With Type Of Coordination 1 Required":"fuse gL/gG: 630 A","Reference code acc. to DIN EN 81346-2":"Q","with high demand rate acc. to SN 31920":"1 000 000","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"610 A","Type of voltage of the control supply voltage":"AC/DC","Limited To 1 S Switching At Zero Current Maximum":"7 484 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"7 484 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"5 978 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"3 765 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"2 887 A; Use minimum cross-section acc. to AC-1 rated value","between coil and main contacts acc. to EN 60947-1":"690 V","Contact rating of auxiliary contacts according to UL":"A600 / Q600","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=139346&mlfb=3RT1076-6AP36-0AE0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1076-6AP36-0AE0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1076-6AP36-0AE0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1076-6AP36-0AE0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}