{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1076-6PP35","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1076-6PP35","canonicalUrl":"https://aoctrl.com/siemens/3RT1076-6PP35","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1076-6PP35","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, order code 3RT1076-6PP35, Size S12, 200-277 V AC coil voltage, screw-type coil terminals, with auxiliary switch.","salesMarkdown":"Its coil is rated for 200-277 V AC, with screw-type coil terminals for secure wiring. For heavy inching or plugging (AC-4), the rate drops to 130 ops/h, reflecting the increased arc stress during reversing or jogging. The contactor is rated for DC switching at 24 V (10 A), 48 V (2 A), 60 V (2 A), and 110 V (1 A), so it can handle small DC loads like brake solenoids or control relays, but the DC ratings are significantly lower than the AC motor ratings — not a part for high-current DC bus switching. Storage range extends to -55 to +80 °C, which is a handling and logistics spec, not an operating condition. The Size S12 frame measures 214 mm high, 180 mm wide, and 225 mm deep — a substantial contactor that requires adequate enclosure depth and side clearance for ventilation and arc chute access. The main power cables accept stranded conductors from 70 to 240 mm², sized for high-current motor circuits. The auxiliary control wiring uses screw terminals accepting 2x (0.5 to 1.5 mm²) solid or 2x (0.75 to 2.5 mm²) stranded, with a maximum of 2x (0.75 to 4 mm²). Mounting is by screw fixing through 11 mm diameter holes; recommended clearances are 10 mm upwards, 20 mm forwards, 10 mm downwards, and 10 mm at the side for arc containment and heat dissipation.","metaTitle":"Siemens 3RT1076-6PP35 SIRIUS Power Contactor, Size S12","metaDescription":"Siemens 3RT1076-6PP35 SIRIUS power contactor, Size S12, 200-277V AC coil, screw terminals. Rated for AC-3e switching at 420 ops/h. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"225 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"180 mm","at AC":"80 ... 100 ms","at DC":"80 ... 100 ms","title":"3RT1076-6PP35","Height":"214 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"70 ... 240 mm²","at 50 Hz":"0.4","at 60 Hz":"0.4","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"200 ... 277 V","description":"power contactor, AC-3e/AC-3 500 A, 250 kW / 400 V AC (50-60 Hz) / DC Uc: 200-277 V PLC input 24 V DC 3-pole, auxiliary contacts 1 NO + 1 NC drive: electronic main circuit: busbar control and auxiliary circuit: screw terminal with remaining lifetime indicator","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Number Of Holes":"1","at AC-1 maximum":"500 1/h","at AC-2 maximum":"170 1/h","at AC-3 maximum":"420 1/h","at AC-4 maximum":"130 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","at AC-3e maximum":"420 1/h","Diameter Of Holes":"11 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S12","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 440 V rated value":"1.4 A","at 480 V rated value":"477 A","at 50 Hz rated value":"200 ... 277 V","at 500 V rated value":"2 A","at 60 Hz rated value":"200 ... 277 V","at 600 V rated value":"472 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"250 kW","For Auxiliary Contacts":"18 ... 14","Width Of Connection Bar":"25 mm","For Main Current Circuit":"Connection bar","at 200/208 V rated value":"150 hp","at 220/230 V rated value":"200 hp","at 460/480 V rated value":"400 hp","at 575/600 V rated value":"500 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Thickness Of Connection Bar":"6 mm","at AC-3 rated value maximum":"1 000 V","at AC in hot operating state":"165 W","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"430 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"05/01/2012","Design Of The Surge Suppressor":"with varistor","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"536 A","at AC-5b up to 400 V rated value":"415 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 500 A (690 V, 100 kA), aM: 500 A (690 V, 50 kA), BS88: 500 A (415 V, 50 kA)","Without Load Current Share Typical":"3.6 W","closing power of magnet coil at DC":"800 W","holding power of magnet coil at DC":"3.6 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 630 A (690 V, 100 kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"55 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","voltage at PLC-control input rated value":"24 V","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Limited To 1 S Switching At Zero Current Maximum":"7 484 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"7 484 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 10 S Switching At Zero Current Maximum":"5 978 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"3 765 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"2 887 A; Use minimum cross-section acc. to AC-1 rated value","type of PLC-control input according to IEC 60947-1":"Type 2","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","operating range factor of the voltage at PLC-control input":"0.8 ... 1.1","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","for short-circuit protection of the RLT relay output required":"miniature fuse: 4 A FF (230 V, Ik= 400 A)","minimum cross-section in main circuit at maximum AC-1 rated value":"370 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ab59d2fdc8dbb6b7099d368100d6e014.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=45880&mlfb=3RT1076-6PP35"},"ai":{"faq":[{"question":"Is 3RT1076-6PP35 suitable for AC-3e applications?","answer":"Yes, it is rated for AC-3e duty with a maximum switching frequency of 420 operations per hour. This covers standard motor starting for pumps, fans, and conveyors."},{"question":"Where can I buy Siemens 3RT1076-6PP35?","answer":"This part is sourced to order against an RFQ. Availability and pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1076-6PP35","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1076-6PP35 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}