{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1076-6SP36","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1076-6SP36","canonicalUrl":"https://aoctrl.com/siemens/3RT1076-6SP36","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1076-6SP36","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S12, order code 3RT1076-6SP36, 200-277 V AC coil, screw-type terminals, MTBF 75 a.","salesMarkdown":"## Siemens 3RT1076-6SP36 SIRIUS Power Contactor — Size S12, 200-277 V AC Coil It is a current-production part, still in active manufacture per the manufacturer's lifecycle record. The coil is rated for 200-277 V AC, with a pickup threshold of 0.8 x rated value and a dropout of 0.4 x rated value at 50/60 Hz. The magnet coil uses screw-type terminals. Rated operational current for the main poles is not directly listed in this excerpt, but the contactor accepts stranded main conductors from 70 to 240 mm², indicating a high-current capability consistent with the S12 frame size. Auxiliary contacts are included. The contactor mounts via screw fixing with four 11 mm diameter holes. ## Duty Ratings and Switching Frequency Maximum switching frequency varies by duty category: AC-1 (resistive) and AC-3 (motor starting) at 200 operations per hour, AC-2 (slip-ring motor) at 170 ops/h, AC-4 (plugging/inching) at 130 ops/h, and AC-3e at 200 ops/h. Arcing time is 10-15 ms. Typical mechanical life is 10,000,000 operations. The auxiliary contact ratings: 10 A at 24 V, 2 A at 48 V, and 2 A at 60 V. These are the rated values for the integrated auxiliary switch block. ## Environmental and Reliability Data The listed MTBF is 75 a (years), a reliability figure that applies under rated conditions per the manufacturer's calculation method. Dimensions: 214 mm height, 160 mm width, 225 mm depth. The contactor is designed for screw-fixing to a mounting plate, not DIN-rail snap-on — panel builders should account for the four-hole pattern with 11 mm diameter holes. For buyers maintaining a BOM line on this SIRIUS contactor, the MTBF of 75 a and mechanical life of 10 million operations provide a basis for preventive replacement intervals in continuous-duty applications.","metaTitle":"Siemens 3RT1076-6SP36 SIRIUS Power Contactor, Size S12, 200-","metaDescription":"Siemens 3RT1076-6SP36 SIRIUS power contactor, size S12. 200-277 V AC coil, screw terminals. MTBF 75 a. Current lifecycle stage. Sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"MTBF":"75 a","Depth":"225 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"160 mm","at AC":"115 ... 130 ms","at DC":"115 ... 130 ms","title":"3RT1076-6SP36","Height":"214 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"70 ... 240 mm²","at 50 Hz":"0.4","at 60 Hz":"0.4","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"200 ... 277 V","description":"power contactor, AC-3e/AC-3 500 A, 250 kW / 400 V AC (50-60 Hz) / DC 200-277 V x (0.8-1.1) F-PLC input 24 V DC 3-pole, auxiliary contacts 2 NO + 2 NC drive: electronic main circuit: busbar control and auxiliary circuit: screw terminal","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Number Of Holes":"1","at AC-1 maximum":"200 1/h","at AC-2 maximum":"170 1/h","at AC-3 maximum":"200 1/h","at AC-4 maximum":"130 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","at AC-3e maximum":"200 1/h","Diameter Of Holes":"11 mm","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Size Of Contactor":"S12","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Power contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 440 V rated value":"1.4 A","at 480 V rated value":"477 A","at 50 Hz rated value":"200 ... 277 V","at 500 V rated value":"2 A","at 60 Hz rated value":"200 ... 277 V","at 600 V rated value":"472 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"250 kW","For Auxiliary Contacts":"18 ... 14","Width Of Connection Bar":"25 mm","For Main Current Circuit":"Connection bar","at 200/208 V rated value":"150 hp","at 220/230 V rated value":"200 hp","at 460/480 V rated value":"400 hp","at 575/600 V rated value":"500 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Safe failure fraction (SFF)":"93 %","Safety-Related Switching On":"No","Thickness Of Connection Bar":"6 mm","at AC-3 rated value maximum":"1 000 V","at AC in hot operating state":"165 W","at AC-2 at 400 V rated value":"250 kW","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"430 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"03/01/2017","Design Of The Surge Suppressor":"with varistor","Of Auxiliary Circuit Rated Value":"6 kV","at AC-5a up to 690 V rated value":"536 A","at AC-5b up to 400 V rated value":"415 A","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 500 A (690 V, 100 kA), aM: 500 A (690 V, 50 kA), BS88: 500 A (415 V, 50 kA)","Without Load Current Share Typical":"3.6 W","closing power of magnet coil at DC":"800 W","holding power of magnet coil at DC":"3.6 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 630 A (690 V, 100 kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","category according to EN ISO 13849-1":"2","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"55 W","stop category according to EN 60204-1":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","voltage at PLC-control input rated value":"24 V","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Recovery Time After Power Failure Typical":"2 s","mirror contact according to IEC 60947-4-1":"Yes","safety device type according to IEC 61508-2":"Type B","Type Of Voltage Of The Control Supply Voltage":"AC/DC","hardware fault tolerance according to IEC 61508":"0","Limited To 1 S Switching At Zero Current Maximum":"7 484 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 5 S Switching At Zero Current Maximum":"7 484 A; Use minimum cross-section acc. to AC-1 rated value","PFHD with high demand rate according to EN 62061":"4.5E-7 1/h","Limited To 10 S Switching At Zero Current Maximum":"5 978 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 30 S Switching At Zero Current Maximum":"3 765 A; Use minimum cross-section acc. to AC-1 rated value","Limited To 60 S Switching At Zero Current Maximum":"2 887 A; Use minimum cross-section acc. to AC-1 rated value","SIL Claim Limit (subsystem) according to EN 62061":"2","PFDavg with low demand rate according to IEC 61508":"0.007","performance level (PL) according to EN ISO 13849-1":"c","type of PLC-control input according to IEC 60947-1":"Type 1","contact rating of auxiliary contacts according to UL":"A600 / P600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","operating range factor of the voltage at PLC-control input":"0.8 ... 1.1","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"370 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/72b3b452e02b30553668ca42e61d4a3f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=907616&mlfb=3RT1076-6SP36"},"ai":{"faq":[{"question":"What is the MTBF of 3RT1076-6SP36?","answer":"The listed MTBF is 75 a (years), calculated under rated conditions per the manufacturer's reliability methodology."},{"question":"Where can I buy 3RT1076-6SP36 and how is it quoted?","answer":"This part is sourced and quoted to order through independent distribution. Submit an RFQ for current availability and pricing — no stock or price figures are published here."},{"question":"What wire sizes does 3RT1076-6SP36 accept for main conductors?","answer":"Stranded main conductors from 70 to 240 mm². Auxiliary/coil terminals accept 2x (0.5-1.5 mm²), 2x (0.75-2.5 mm²), or max 2x (0.75-4 mm²) solid or stranded."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1076-6SP36","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1076-6SP36 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}