{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1265-6AV36","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1265-6AV36","canonicalUrl":"https://aoctrl.com/siemens/3RT1265-6AV36","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1265-6AV36","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, vacuum contactor, size S10, order code 3RT1265-6AV36, rated coil 380-420 V AC, auxiliary switch included, screw fixing.","salesMarkdown":"It lands in a control panel via screw fixing, with a 210 mm height, 145 mm width, and 206 mm depth, and the mounting position allows ±22.5° rotation on a vertical surface or standing on a horizontal one. The coil is rated 380…420 V AC at 50/60 Hz, with a pick-up of 0.8 x rated value and a drop-out of 0.9 x rated value — so on a nominal 400 V line the contactor pulls in reliably down to about 320 V and drops out at about 360 V. The coil connection uses screw-type terminals. The auxiliary switch (included) carries 10 A at 24 V DC, 2 A at 48 V or 60 V DC, and 1 A at 110 V DC — enough for a PLC input or a relay interlock, but watch the DC derating above 24 V. ## Switching rates and thermal cycling Maximum switching rates: 750 operations/hour in AC-1 (resistive), AC-3 (motor start/run), and AC-3e (enhanced motor) duty; 250 ops/hour in AC-2 (slip-ring motor) and AC-4 (plugging/inching). ## Termination and clearance Main power terminals accept stranded wire from 70 mm² up to 240 mm² — sized for the full load current of this frame. Auxiliary terminals accept solid or stranded 0.5…1.5 mm² (two conductors) or up to 4 mm² (single). Minimum clearance to grounded parts: 10 mm upwards, 20 mm forwards, 10 mm sideways, 10 mm downwards — keep that in the panel layout.","metaTitle":"Siemens SIRIUS 3RT1265-6AV36 Vacuum Contactor, Size S10, 380","metaDescription":"Siemens SIRIUS 3RT1265-6AV36 vacuum contactor, size S10. Rated coil 380-420V AC 50/60Hz. 206 mm depth. Current lifecycle stage. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"206 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"145 mm","at AC":"40 ... 80 ms","at DC":"40 ... 80 ms","title":"3RT1265-6AV36","Height":"210 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"70 ... 240 mm²","at 50 Hz":"0.9","at 60 Hz":"0.9","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"380 ... 420 V","description":"vacuum contactor AC-3e/AC-3 265 A, 132 kW / 400 V, 3-pole, Uc: 380-420 V AC(50-60 Hz) / DC drive: conventional auxiliary contacts 2 NO + 2 NC main circuit: busbar control and auxiliary circuit: screw terminal","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Number Of Holes":"1","at AC-1 maximum":"750 1/h","at AC-2 maximum":"250 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","at AC-3e maximum":"750 1/h","Diameter Of Holes":"11 mm","Mounting Position":"+/-22,5° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface; standing, on horizontal mounting surface","Size Of Contactor":"S10","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Vacuum contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 480 V rated value":"240 A","at 50 Hz rated value":"380 ... 420 V","at 500 V rated value":"2 A","at 60 Hz rated value":"380 ... 420 V","at 600 V rated value":"242 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"355 kW","For Auxiliary Contacts":"18 ... 14","Width Of Connection Bar":"25 mm","For Main Current Circuit":"Connection bar","at 200/208 V rated value":"75 hp","at 220/230 V rated value":"100 hp","at 460/480 V rated value":"200 hp","at 575/600 V rated value":"250 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Thickness Of Connection Bar":"6 mm","at AC-3 rated value maximum":"1 000 V","at AC in hot operating state":"36 W","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"230 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"05/01/2012","Design Of The Surge Suppressor":"with varistor","at AWG cables for main contacts":"2/0 ... 500 kcmil","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 500 A (690 V, 100 kA), aM: 400 A (690 V, 50 kA), BS88: 450 A (415 V, 50 kA)","Without Load Current Share Typical":"8.2 W","closing power of magnet coil at DC":"700 W","holding power of magnet coil at DC":"8.2 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 500 A (690 V, 100 kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","at AC in hot operating state per pole":"12 W","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","Type Of Voltage Of The Control Supply Voltage":"AC/DC","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"185 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8b792fa5cf1abab1f5b78bd7cef59427.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=109829&mlfb=3RT1265-6AV36"},"ai":{"faq":[{"question":"What is 3RT1265-6AV36's listed depth?","answer":"The depth is 206 mm."},{"question":"What wire sizes does the auxiliary terminal accept?","answer":"Solid: 2x (0.5…1.5 mm²), 2x (0.75…2.5 mm²), max. 2x (0.75…4 mm²). Stranded: same ranges."},{"question":"What compliance documentation does Siemens provide for 3RT1265-6AV36?","answer":"As a Siemens SIRIUS product, it typically carries CE, UL, CSA, and RoHS/REACH declarations — confirm the specific certificate numbers with the order documentation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1265-6AV36","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1265-6AV36 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}