{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1276-6AP36-0KA1","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1276-6AP36-0KA1","canonicalUrl":"https://aoctrl.com/siemens/3RT1276-6AP36-0KA1","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1276-6AP36-0KA1","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, vacuum contactor, S12 frame, 3RT1276-6AP36-0KA1, 220-240 V AC coil, screw-type terminals, 214 x 160 x 225 mm.","salesMarkdown":"The Siemens 3RT1276-6AP36-0KA1 is a SIRIUS vacuum contactor in the S12 frame size. The vacuum switching technology means the arc is extinguished in a sealed bottle, giving it a mechanical service life of 10,000,000 operations typical. The coil is rated 220-240 V AC and terminates in screw-type terminals. The main circuit accepts stranded conductors from 70 to 240 mm² — sized for the S12 frame's current-carrying capacity. Auxiliary wiring accepts 2x (0.5 to 1.5 mm²) solid or 2x (0.75 to 2.5 mm²) stranded, with a maximum of 2x (0.75 to 4 mm²). At 214 mm high, 160 mm wide, and 225 mm deep, the S12 frame is a substantial piece of iron — plan the gland plate and DIN-rail clearance accordingly. The depth of 225 mm is the dimension that most often surprises panel builders who are used to IEC 60947-4-1 contactors in smaller frames. The auxiliary contact ratings are given at specific control voltages: 10 A at 24 V, 2 A at 48 V, 2 A at 60 V, and 1 A at 110 V — these are the switching capacities for the built-in auxiliary switch, not the main pole ratings.","metaTitle":"Siemens 3RT1276-6AP36-0KA1 SIRIUS Vacuum Contactor, S12 Fram","metaDescription":"Siemens SIRIUS 3RT1276-6AP36-0KA1 vacuum contactor, S12 frame, 220-240 V AC coil, screw terminals, 214x160x225 mm. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"225 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"160 mm","at AC":"60 ... 100 ms","at DC":"60 ... 100 ms","Height":"214 mm","Upwards":"10 mm","Forwards":"20 mm","Stranded":"70 ... 240 mm²","at 50 Hz":"0.9","at 60 Hz":"0.9","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"10 mm","Rated Value":"220 ... 240 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","Number Of Holes":"1","at AC-1 maximum":"700 1/h","at AC-2 maximum":"250 1/h","at AC-3 maximum":"750 1/h","at AC-4 maximum":"250 1/h","lifecycle_stage":"current","Auxiliary Switch":"Yes","During Operation":"-25 ... +60 °C","Fastening Method":"screw fixing","Full-Scale Value":"1.1","at AC-3e maximum":"750 1/h","Diameter Of Holes":"11 mm","Mounting Position":"+/-22,5° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface; standing, on horizontal mounting surface","Size Of Contactor":"S12","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Vacuum contactor","at 24 V rated value":"10 A","at 48 V rated value":"2 A","at 60 V rated value":"2 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 125 V rated value":"0.9 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 480 V rated value":"477 A","at 50 Hz rated value":"220 ... 240 V","at 500 V rated value":"2 A","at 60 Hz rated value":"220 ... 240 V","at 600 V rated value":"472 A","at 690 V rated value":"1 A","Side-By-Side Mounting":"Yes","at 1000 V rated value":"710 kW","For Auxiliary Contacts":"18 ... 14","Width Of Connection Bar":"25 mm","For Main Current Circuit":"Connection bar","at 200/208 V rated value":"150 hp","at 220/230 V rated value":"200 hp","at 460/480 V rated value":"400 hp","at 575/600 V rated value":"500 hp","Relative Humidity Minimum":"10 %","Of Main Circuit Rated Value":"8 kV","Thickness Of Connection Bar":"6 mm","at AC-3 rated value maximum":"1 000 V","at AC-2 at 400 V rated value":"250 kW","at AC-3e rated value maximum":"1 000 V","at AC-4 at 400 V rated value":"430 A","safety-related switching OFF":"Yes","Substance Prohibitance (Date)":"05/01/2012","Design Of The Surge Suppressor":"with varistor","at AWG cables for main contacts":"2/0 ... 500 kcmil","Of Auxiliary Circuit Rated Value":"6 kV","For Auxiliary And Control Circuit":"screw-type terminals","Function Module For Communication":"No","With Type Of Assignment 2 Required":"gG: 800 A (690 V, 50 kA), aM: 630 A (690 V, 50 kA), BS88: 800 A (415 V, 50 kA)","closing power of magnet coil at DC":"920 W","holding power of magnet coil at DC":"10 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG: 800 A (690 V, 100 kA)","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes","Type Of Voltage Of The Control Supply Voltage":"AC/DC","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of Main Circuit With Degree Of Pollution 3 Rated Value":"1 000 V","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Of Auxiliary Circuit With Degree Of Pollution 3 Rated Value":"500 V","For Short-Circuit Protection Of The Auxiliary Switch Required":"gG: 10 A (500 V, 1 kA)","minimum cross-section in main circuit at maximum AC-1 rated value":"370 mm²","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=146&mlfb=3RT1276-6AP36-0KA1","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1276-6AP36-0KA1/alternatives.json"},"ai":{"faq":[{"question":"What are the key dimensions for panel planning?","answer":"The contactor measures 214 mm high, 160 mm wide, and 225 mm deep. Minimum clearance distances are 10 mm downwards, 10 mm upwards, 10 mm at the side, and 20 mm forwards."},{"question":"What conductor sizes does the main circuit accept?","answer":"The main circuit accepts stranded conductors from 70 to 240 mm². The auxiliary circuit accepts 2x (0.5 to 1.5 mm²) solid or 2x (0.75 to 2.5 mm²) stranded, with a maximum of 2x (0.75 to 4 mm²)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1276-6AP36-0KA1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1276-6AP36-0KA1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}