{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1316-1AR60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1316-1AR60","canonicalUrl":"https://aoctrl.com/siemens/3RT1316-1AR60","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1316-1AR60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT1316-1AR60 power contactor, size S00, 4 NO main contacts, 4 kW at 400 V AC-2, 45 mm width, screw terminals, DIN rail mount.","salesMarkdown":"## SIRIUS S00 power contactor — 4 NO, 4 kW AC-2 The Siemens 3RT1316-1AR60 is a SIRIUS-branded power contactor in the S00 frame size, carrying 4 normally-open main contacts and no NC main contacts. Mounts on 35 mm standard rail per DIN EN 50022, screw or snap-on. Side-by-side mounting is permitted with 6 mm spacing at the side. Front protection is IP20; the terminals are also IP20. The screw-type terminals accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²) solid/stranded conductors, or 2x (20 to 16), 2x (18 to 14), 1x 12 AWG. Strip and torque per the terminal marking on the contactor. Rated insulation voltage 400 V at 50 Hz, 400 to 440 V at 60 Hz. Operating frequency 50/60 Hz. The auxiliary contact ratings cover 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V, 6 A at 230 V, and 3 A at 400 V. Mechanical life is 30 million operating cycles.","metaTitle":"Siemens 3RT1316-1AR60 SIRIUS Power Contactor, 4 NO, 4 kW AC-","metaDescription":"Siemens SIRIUS 3RT1316-1AR60 power contactor, size S00, 4 NO main contacts, 4 kW at 400 V AC-2. Current lifecycle stage. 45 mm wide, DIN rail mount. Available to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","Maximum":"2 000 m","at 50 Hz":"0.85 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"400 V","at 60 Hz rated value":"400 ... 440 V","Instantaneous Contact":"0","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","at AC-2 at 400 V rated value":"4 kW","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"4","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"4","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"18 A","Apparent holding power of magnet coil at AC":"5.1 V·A","Apparent pick-up power of magnet coil at AC":"31.7 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.77","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=254006&mlfb=3RT1316-1AR60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1316-1AR60/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RT1316-1AR60?","answer":"Submit an RFQ through this listing. The part is sourced to order through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is 3RT1316-1AR60's listed depth?","answer":"The depth is 72 mm."},{"question":"What conductor sizes does the 3RT1316-1AR60 accept?","answer":"The screw terminals accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²) solid/stranded, or 2x (20 to 16), 2x (18 to 14), 1x 12 AWG."},{"question":"What compliance documentation does Siemens provide for 3RT1316-1AR60?","answer":"The part carries the reference code Q per DIN EN 81346-2. Standard Siemens documentation includes the declaration of conformity and CE marking; specific RoHS, REACH, and UL documentation should be requested at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1316-1AR60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1316-1AR60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}